58 resultados para SYNCHRONOUS GENERATOR
Resumo:
Mid to high latitude forest ecosystems have undergone several major compositional changes during the Holocene. The temporal and spatial patterns of these vegetation changes hold potential information to their causes and triggers. Here we test the hypothesis that the timing of vegetation change was synchronous on a sub-continental scale, which implies a common trigger or a step-like change in climate parameters. Pollen diagrams from selected European regions were statistically divided into assemblage zones and the temporal pattern of the zone boundaries analysed. The results show that the temporal pattern of vegetation change was significantly different from random. Times of change cluster around8.2, 4.8, 3.7, and 1.2 ka, while times of higher than average stability were found around 2.1 and 5.1 ka.Compositional changes linked to the expansion of Corylus avellana and Alnus glutinosa centre around 10.6 and 9.5 ka, respectively. A climatic trigger initiating these changes may have occurred 0.5 to 1 ka earlier, respectively. The synchronous expansion of C. avellana and A. glutinosa exemplify that dispersal is not necessarily followed by population expansion. The partly synchronous, partly random expansion of A. glutinosa in adjacent European regions exemplifies that sudden synchronous population expansions are not species specific traits but vary regionally.
Resumo:
True random number generation is crucial in hardware security applications. Proposed is a voltage-controlled true random number generator that is inherently field-programmable. This facilitates increased entropy as a randomness source because there is more than one configuration state which lends itself to more compact and low-power architectures. It is evaluated through electrical characterisation and statistically through industry-standard randomness tests. To the best of the author's knowledge, it is one of the most efficient designs to date with respect to hardware design metrics.
Resumo:
THE MACHINIST LANDSCAPE: AN ENTROPIC GRID OF VARIANCE
‘By drawing a diagram, a ground plan of a house, a street plan to the location of a site, or a topographic map, one draws a “logical two dimensional picture”. A “logical picture” differs from a natural or realistic picture in that it rarely looks like the thing it stands for.’
A Provisional Theory of Non-Sites, Robert Smithson (1968)
Between design and ground there are variances, deviations and gaps. These exist as physical interstices between what is conceptualised and what is realised; and they reveal moments in the design process that resist the reconciliation of people and their environment (McHarg 1963). The Machinist Landscape interrogates the significance of these variances through the contrasting processes of coppice and photovoltaic energy. It builds on the potential of these gaps, and in doing so proposes that these spaces of variance can reveal the complexity of relationships between consumption and remediation, design and nature.
Fresh Kills Park, and in particular the draft master plan (2006), offers a framework to explore this artificial construct. Central to the Machinist Landscape is the analysis of the landfill gas collection system, planned on a notional 200ft grid. Variations are revealed between this diagrammatic grid measure and that which has been constructed on the site. These variances between the abstract and the real offer the Machinist Landscape a powerful space of enquiry. Are these gaps a result of unexpected conditions below ground, topographic nuances or natural phenomena? Does this space of difference, between what is planned and what is constructed, have the potential to redefine the dynamic processes and relations with the land?
The Machinist Landscape is structured through this space of variance with an ‘entropic grid’, the under-storey of which hosts a carefully managed system of short-rotation coppice (SRC). The coppice, a medieval practice related to energy, product, and space, operates on theoretical and programmatic levels. It is planted along a structure of linear bunds, stabilized through coppice pole retaining structures and enriched with nutrients from coppice produced bio-char. Above the coppice is built an upper-storey of photovoltaic (PV); its structures fabricated from the coppiced timber and the PV produced with graphene from coppice charcoal processes.
Resumo:
A generator for the automated design of Discrete Cosine Transform (DCT) cores is presented. This can be used to rapidly create silicon circuits from a high level specification. These compare very favourably with existing designs. The DCT cores produced are scaleable in terms of point size as well as input/output and coefficient wordlengths. This provides a high degree of flexibility. An example, 8-point 1D DCT design, produced occupies less than 0.92 mm when implemented in a 0.35µ double level metal CMOS technology. This can be clocked at a rate of 100MHz.
Resumo:
The application of blown jet vortex generators to control flow separation in a diffuser with an opening angle of 10° has been studied using the computational fluid dynamics (CFD) code Fluent 6™. Experimental data is available for the uncontrolled flow in the diffuser. The section of the duct upstream of the diffuser has a height H equal to 15 mm; its length and breadth are 101H and 41H respectively; the diffuser has an expansion ratio of 4.7:1. Fully developed flow is achieved upstream of the diffuser. Pipes of diameters equal to 1.5%, 2.5% and 5% of H were considered; pitch angle was constant at 45° and yaw angle was fixed at 60°; velocity ratio was varied from 1.7 to 8.0; both co-rotating and counter-rotating arrays were studied. The best results were obtained with a counter-rotating array of generators with a hole diameter of 5% of H and a velocity ratio of 3.7.
Resumo:
Large scale wind farms are subject to tripping, as a consequence of turbine failure, over-sensitive protection, turbines not equipped with low-voltage ride through (LVRT), and reactive power compensation device defects which can lead to voltage rises. This paper considers pertinent issues which render tripping based on a study of LVRT and wind farm protection, with methods to avoid large scale wind generator tripping proposed. The results of LVRT field tests in Jiuquan, China in December 2012 show that the proposed approaches are effective. The paper also presents work which proposes an early warning system to forecast the risk of wind power tripping.
Resumo:
The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A dasiadecoupledpsila strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In addition, a case study is developed to validate the proposed strategy under different wind penetrations levels. The simulations show that suitable configuration of the decoupled strategy can be deployed to improve system voltage stability and inertial response for a range of scenarios, especially at high wind penetration. The conclusions are placed in context of the practical limitations of the technology employed and the system conditions.
Resumo:
This paper studies the system modelling and control aspects of switched reluctance generator (SRG) based variable speed wind turbines. A control system is implemented to provide proper operation of the SRG as well as power tracking capabilities for varying wind speeds. The control system for the grid side inverter that will allow the SRG to properly generate power to the system is also presented. Studies are presented of both the SRG and inverter control systems capabilities during a balanced three-phase fault. The paper will demonstrate that the SRG based wind turbine presents a feasible variable wind speed solution with good fault response capabilities.
Resumo:
Two case studies are presented in this paper to demonstrate the impact of different power system operation conditions on the power oscillation frequency modes in the Irish power system. A simplified 2 area equivalent of the Irish power system has been used in this paper, where area 1 represents the Republic of Ireland power system and area 2 represents the Northern Ireland power system.
The potential power oscillation frequency modes on the interconnector during different operation conditions have been analysed in this paper. The main objective of this paper is to analyse the influence of different operation conditions involving wind turbine generator (WTG) penetration on power oscillation frequency modes using phasor measurement unit (PMU) data.
Fast Fourier transform (FFT) analysis was performed to identify the frequency oscillation mode while correlation coefficient analysis was used to determine the source of the frequency oscillation. The results show that WTG, particularly fixed speed induction generation (FSIG), gives significant contribution to inter-area power oscillation frequency modes during high WTG operation.
Resumo:
Just before the onset of the Younger Dryas (YD) cold event, several stomatal proxy-based pCO2 records have shown a sharp increase in atmospheric CO2 concentration (pCO2) of between ca 50 and 100 ppm, followed by a rapid decrease of similar or even larger magnitude. Here we compare one of these records, a high-resolution pCO2 record from southern Sweden, with the IntCal13 record of radiocarbon (Δ14C). The two records show broadly synchronous fluctuations at the YD onset. Specifically, the IntCal13 record documents decreasing Δ14C just before the YD onset when pCO2 peaks, consistent with a source of “old” CO2 from the deep ocean. We propose that this fluctuation occurred due to a major ocean flushing event. The cause of the flushing event remains speculative but could be related to the hypothesis of the glacial ocean as a thermobaric capacitor. We confirm that the earth system can produce such large multi-decadal timescale fluctuations in pCO2 through simulating an artificial ocean flushing event with the GENIE Earth System Model. We suggest that sharp transitions of pCO2 may have remained undetected so far in ice cores due to inter-firn gas exchange and time-averaging. The stomatal proxy record is a powerful complement to the ice core records for the study of rapid climate change.
Resumo:
In this paper, a new field-programmable gate array (FPGA) identification generator circuit is introduced based on physically unclonable function (PUF) technology. The new identification generator is able to convert flip-flop delay path variations to unique n-bit digital identifiers (IDs), while requiring only a single slice per ID bit by using 1-bit ID cells formed as hard-macros. An exemplary 128-bit identification generator is implemented on ten Xilinx Spartan-6 FPGA devices. Experimental results show an uniqueness of 48.52%, and reliability of 92.41% over a 25°C to 70°C temperature range and 10% fluctuation in supply voltage