45 resultados para Physicians in literature


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To evaluate the impact of a provider initiated primary care outreach intervention compared with usual care among older adults at risk of functional decline. Design: Randomised controlled trial. Setting: Patients enrolled with 35 family physicians in five primary care networks in Hamilton, Ontario, Canada. Participants Patients: were eligible if they were 75 years of age or older and were not receiving home care services. Of 3166 potentially eligible patients, 2662 (84%) completed the validated postal questionnaire used to determine risk of functional decline. Of 1724 patients who met the risk criteria, 769 (45%) agreed to participate and 719 were randomised. Intervention: The 12 month intervention, provided by experienced home care nurses in 2004-6, consisted of a comprehensive initial assessment using the resident assessment instrument for home care; collaborative care planning with patients, their families, and family physicians; health promotion; and referral to community health and social support services. Main outcome measures: Quality adjusted life years (QALYs), use and costs of health and social services, functional status, self rated health, and mortality. Results: The mean difference in QALYs between intervention and control patients during the study period was not statistically significant (0.017, 95% confidence interval -0.022 to 0.056; P=0.388). The mean difference in overall cost of prescription drugs and services between the intervention and control groups was not statistically significant, (-$C165 (£107; €118; $162), 95% confidence interval -$C16 545 to $C16 214; P=0.984). Changes over 12 months in functional status and self rated health were not significantly different between the intervention and control groups. Ten patients died in each group. Conclusions: The results of this study do not support adoption of this preventive primary care intervention for this target population of high risk older adults. Trial registration: Clinical trials NCT00134836.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The design of a System-on-a-Chip (SoC) demonstrator for a baseline JPEG encoder core is presented. This combines a highly optimized Discrete Cosine Transform (DCT) and quantization unit with an entropy coder which has been realized using off-the-shelf synthesizable IP cores (Run-length coder, Huffman coder and data packer). When synthesized in a 0.35 µm CMOS process, the core can operate at speeds up to 100 MHz and contains 50 k gates plus 11.5 kbits of RAM. This is approximately 20% less than similar JPEG encoder designs reported in literature. When targeted at FPGA the core can operate up to 30 MHz and is capable of compressing 9-bit full-frame color input data at NTSC or PAL rates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper examines the impact of changes in the medical marketplace on medicalization in U.S. society. Using four cases (Viagra, Paxil, human growth hormone and in vitro fertilization), we focus on two aspects of the changing medical marketplace: the role of direct-to-consumer advertising of prescription drugs and the emergence of private medical markets. We demonstrate how consumers and pharmaceutical corporations contribute to medicalization, with physicians, insurance coverage, and changes in regulatory practices playing facilitating roles. In some cases, insurers attempt to counteract medicalization by restricting access. We distinguish mediated and private medical markets, each characterized by differing relationships with corporations, insurers, consumers, and physicians. In the changing medical environment, with medical markets as intervening factors, corporations and insurers are becoming more significant determinants in the medicalization process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PROBLEM BEING ADDRESSED: Family physicians face innumerable challenges to delivering quality palliative home care to meet the complex needs of end-of-life patients and their families. OBJECTIVE OF PROGRAM: To implement a model of shared care to enhance family physicians' ability to deliver quality palliative home care, particularly in a community-based setting. PROGRAM DESCRIPTION: Family physicians in 3 group practices (N = 21) in Ontario's Niagara West region collaborated with an interprofessional palliative care team (including a palliative care advanced practice nurse, a palliative medicine physician, a bereavement counselor, a psychosocial-spiritual advisor, and a case manager) in a shared-care partnership to provide comprehensive palliative home care. Key features of the program included systematic and timely identification of end-of-life patients, needs assessments, symptom and psychosocial support interventions, regular communication between team members, and coordinated care guided by outcome-based assessment in the home. In addition, educational initiatives were provided to enhance family physicians' knowledge and skills. CONCLUSION: Because of the program, participants reported improved communication, effective interprofessional collaboration, and the capacity to deliver palliative home care, 24 hours a day, 7 days a week, to end-of-life patients in the community.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report an unusual case of horizontal corneal Descemet's membrane break due to birth trauma. The patient had a difficult birth with trauma to her right eye and poor vision. However unlike the reports in literature, which describe these breaks to have a characteristic vertical or vertically oblique orientation in birth trauma, the breaks in our patient were horizontal. No other cause was found for these Descemet's breaks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Impeller speed is one of the most crucial process variables that affect the properties of the granules produced in a high-shear granulator. Several reports can be found in literature that discuss the influence of impeller speed on the granules size. For instance some researchers like Knight report an increase of granule size with impeller speed [1] and [2], while others (Scheaefer et al. and Ramaker et al.) observed a decrease of granules size with increasing impeller speed [3] and [4]. However there is limited work reported in literature on the effect of the impeller speed on the mechanical properties of granules. Mechanical properties are important as they affect the performance of the granules on the other downstream process such as transportation and handling. The work reported here serves to address the missing in knowledge gap regarding the influence of impeller speed on mechanical properties granules. How the granulation system responds to the changes in the impeller speeds depends on binder that is used in the process. For this reason the two extreme cases, of a low viscosity binder system and high viscosity binder system are considered in this research. For low viscosity binder system it was observed that the granule size decreased with increasing impeller speed whilst for the high viscosity binder system the opposite was observed by Knight [1]. The granule strength, the Young's modulus and yield strength of the high viscosity granules increased with increasing impeller speed where as the opposite trends were observed for the low viscosity binder granules.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background; Weaning from mechanical ventilation is influenced by patient, clinician, and organizational factors.

Objective: To identify factors that may influence weaning and adoption of weaning strategies and tools, clinicians’ perceptions of weaning strategies, and weaning experiences of patients and patients’ families.

Method: A scoping review of indexed and nonindexed publications (1990–2012) was done. Qualitative studies of health care providers, patients, and patients’ families involved in weaning were included. Two investigators independently screened 8350 publications and extracted data from 43 studies. Study themes were content analyzed to identify common categories and themes within the categories.

Results: The study sample consisted of nurses in 15 studies, nurses and patients in 1 study, various health care providers in 11, patients in 10, and physicians in 4. Categories identified were as follows: for nurses, role or scope of practice, informing decision making, and influence on weaning outcome; for health care providers, factors influencing weaning decisions or use of protocols, role or scope of practice related to weaning, and organizational structure or practice environment; for patients, experience of mechanical ventilation and weaning, experience of the intensive care environment, psychological phenomena, and enabling success in weaning; and for physicians, tools or factors to facilitate weaning decisions and perceptions of nurses’ role and scope of practice.

Conclusions: Important issues identified were perceived importance of interprofessional collaboration and communication, need to combine subjective knowledge of the patient with objective clinical data, balancing of weaning systematization with individual needs, and appreciation of the physical and psychological work of weaning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many kinetic models have appeared in literature in past decades using two main approaches: the traditional global kinetics approach, or the more complex micro-kinetics approach. Whether global or micro-kinetics, kinetic models have been based on experimental data obtained at the end of the monolith. The experimental procedure using end pipe analysis may give an accurate overview of the reaction mechanisms that occur; however, the lack of information from within the catalyst can ultimately lead to inaccuracies in the kinetic model and parameters used.

Using SpaciMS, a spatially resolved experimental technique developed at the Queen's University Belfast, information from within the catalyst can be obtained. This minimally invasive technique provides detailed information of the gas concentration and temperature profile from inside the catalytic monolith. This paper presents a kinetic model and simulations validated against experimental data obtained from three positions inside the catalyst monolith at 2, 14, and 26 mm in, using data from the SpaciMS. Also, simulations of end pipe analysis, using a commercial reactor, for the CO oxidation are presented and analyzed. The simulations presented are for varying concentrations of both CO and O2 (0.5 % and 1 % CO, 0.5 % and 2 % O2) for both the global and micro-kinetic approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thermal reactions proceed optimally when they are rapidly heated to the highest tolerable temperature, held there for the shortest possible time and then quenched. This is explained through assessments of reaction kinetics in literature examples and models. Although presently available microwave equipment is better suited to rapid heating than resistance-heated systems, the findings do not depend upon the method of heating. Claims that microwave heated reactions proceed faster and more cleanly than their conventionally heated counterparts are valid only when comparably rapid heating and cooling cannot be obtained by conventional heating. These findings suggest that rigid adherence to the sixth principle of green chemistry, relating to the use of ambient temperature and pressure, may not always afford optimal results. © 2010 The Royal Society of Chemistry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract. Single-zone modelling is used to assess different collections of impeller 1D loss models. Three collections of loss models have been identified in literature, and the background to each of these collections is discussed. Each collection is evaluated using three modern automotive turbocharger style centrifugal compressors; comparisons of performance for each of the collections are made. An empirical data set taken from standard hot gas stand tests for each turbocharger is used as a baseline for comparison. Compressor range is predicted in this study; impeller diffusion ratio is shown to be a useful method of predicting compressor surge in 1D, and choke is predicted using basic compressible flow theory. The compressor designer can use this as a guide to identify the most compatible collection of losses for turbocharger compressor design applications. The analysis indicates the most appropriate collection for the design of automotive turbocharger centrifugal compressors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the numerical simulation of the ultimate behaviour of 85 one-way and two-way spanning laterally restrained concrete slabs of variable thickness, span, reinforcement ratio, strength and boundary conditions reported in literature by different authors. The developed numerical model was described and all the assumptions were illustrated. ABAQUS, a Finite Element Analysis suite of software, was employed. Non-linear implicit static general analysis method offered by ABAQUS was used. Other analysis methods were also discussed in general in terms of application such as Explicit Dynamic Analysis and Riks method. The aim is to demonstrate the ability and efficacy of FEA to simulate the ultimate load behaviour of slabs considering different material properties and boundary conditions. The authors intended to present a numerical model that provides consistent predictions of the ultimate behaviour of laterally restrained slabs that could be used as an alternative for expensive real life testing as well as for the design and assessment of new and existing structures respectively. The enhanced strength of laterally-restrained slabs compared with conventional design methods predictions is believed to be due to compressive membrane action (CMA). CMA is an inherent phenomenon of laterally restrained concrete beams/slabs. The numerical predictions obtained from the developed model were in good correlation with the experimental results and with those obtained from the CMA method developed at the Queen’s University Belfast, UK.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This book provides a comprehensive tutorial on similarity operators. The authors systematically survey the set of similarity operators, primarily focusing on their semantics, while also touching upon mechanisms for processing them effectively.

The book starts off by providing introductory material on similarity search systems, highlighting the central role of similarity operators in such systems. This is followed by a systematic categorized overview of the variety of similarity operators that have been proposed in literature over the last two decades, including advanced operators such as RkNN, Reverse k-Ranks, Skyline k-Groups and K-N-Match. Since indexing is a core technology in the practical implementation of similarity operators, various indexing mechanisms are summarized. Finally, current research challenges are outlined, so as to enable interested readers to identify potential directions for future investigations.

In summary, this book offers a comprehensive overview of the field of similarity search operators, allowing readers to understand the area of similarity operators as it stands today, and in addition providing them with the background needed to understand recent novel approaches.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Models of ground source heat pump (GSHP) systems are used as an aid for the correct design and optimization of the system. For this purpose, it is necessary to develop models which correctly reproduce the dynamic thermal behavior of each component in a short-term basis. Since the borehole heat exchanger (BHE) is one of the main components, special attention should be paid to ensuring a good accuracy on the prediction of the short-term response of the boreholes. The BHE models found in literature which are suitable for short-term simulations usually present high computational costs. In this work, a novel TRNSYS type implementing a borehole-to-ground (B2G) model, developed for modeling the short-term dynamic performance of a BHE with low computational cost, is presented. The model has been validated against experimental data from a GSHP system located at Universitat Politècnica de València, Spain. Validation results show the ability of the model to reproduce the short-term behavior of the borehole, both for a step-test and under normal operating conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Simulation is a well-established and effective approach to the development of fuel-efficient and low-emissions vehicles in both on-highway and off-highway applications.

The simulation of on-highway automotive vehicles is widely reported in literature, whereas research relating to non-automotive and off-highway vehicles is relatively sparse. This review paper focuses on the challenges of simulating such vehicles and discusses the differences in the approach to drive cycle testing and experimental validation of vehicle simulations. In particular, an inner-city diesel-electric hybrid bus and an ICE (Internal Combustion Engine) powered forklift truck will be used as case studies.

Computer prediction of fuel consumption and emissions of automotive vehicles on standardised drive cycles is well-established and commercial software packages such as AVL CRUISE have been specifically developed for this purpose. The vehicles considered in this review paper present new challenges from both the simulation and drive-cycle testing perspectives. For example, in the case of the forklift truck, the drive cycles involve reversing elements, variable mass, lifting operations, and do not specify a precise velocity-time profile. In particular, the difficulties associated with the prediction of productivity, i.e. the maximum rate of completing a series of defined operations, are discussed. In the case of the hybrid bus, the standardised drive cycles are unrepresentative of real-life use and alternative approaches are required in the development of efficient and low-emission vehicles.

Two simulation approaches are reviewed: the adaptation of a standard automotive vehicle simulation package, and the development of bespoke models using packages such as MATLAB/Simulink.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Currently, micro-joining of plastic parts to metal parts in medical devices is achieved by using medical adhesives, For example, pacemakers, defibrillators and neurological stimulators are designed using silicone adhesive to seal the joint between the polyurethane connector module and the titanium can [1]. Nevertheless, the use of adhesive is problematic because it requires a long time to cure and has high tendency to produce leachable products which might be harmful to the human body. An alternative for directly joining plastics to metal without adhesive is therefore required. Laser transmission joining (LTJ) is growing in importance, and has the potential to gain the niche in micro-fabrication of plastics-metal hybrid joints for medical device applications. The possibility of directly joining plastics to metal by LTJ technique have been demonstrated by a number of studies in recent literature [2]. The widely-accepted understanding of LTJ between plastics and metal is that generation and rapid expansion of micro-bubbles at the plastics-metal interface exert high local pressure to press the melted plastics towards the metal surface features during the laser processing [2]. This subsequently creates the plastics-metal hybrid joint by the mechanisms of mechanical interlocking as well as chemical and physical bonds between the plastics and metal surfaces. Although the micro-bubbles can help promote the mechanical interlocking effect to increase the joint strength, the creation of bubble is a random and complex process depending on the complicated interactions between the laser intensity, thermal degradation properties of plastics, surface temperature and topographical features of metal. In an ideal situation, it is desirable to create the hybrid plastics-metal joint without bubbles. However, the mechanical performance of the hybrid plastics-metal joint without bubbles is still unknown, and systematic comparison between the hybrid joints with and without bubbles is lacking in literature. This becomes the objective of this study. In this work, the laser process parameters were carefully chosen from a preliminary study, such that different hybrid joints: with and without bubbles can be produced and compared. Biocompatible PET and commercially pure Ti were selected as materials for laser joining.