51 resultados para Four-frequency Impedance Measurement
Resumo:
The purpose of this study was to examine the behavioural responses of infants to pain stimuli across different developmental ages. Eighty infants were included in this cross-sectional design. Four subsamples of 20 infants each included: (1) premature infants between 32 and 34 weeks gestational age undergoing heel-stick procedure; (2) full-term infants receiving intramuscular vitamin K injection; (3) 2-month-old infants receiving subcutaneous injection for immunisation against DPT; and (4) 4-month-old infants receiving subcutaneous injection for immunisation against DPT. Audio and video recordings were made for 15 sec from stimulus. Cry analysis was conducted on the first full expiratory cry by FFT with time and frequency measures. Facial action was coded using the Neonatal Facial Action Coding System (NFCS). Results from multivariate analysis showed that premature infants were different from older infants, that full-term newborns were different from others, but that 2- and 4-month-olds were similar. The specific variables contributing to the significance were higher pitched cries and more horizontal mouth stretch in the premature group and more taut tongue in the full-term newborns. The results imply that the premature infant has the basis for communicating pain via facial actions but that these are not well developed. The full-term newborn is better equipped to interact with his caretakers and express his distress through specific facial actions. The cries of the premature infant, however, have more of the characteristics that are arousing to the listener which serve to alert the caregiver of the state of distress from pain.
Resumo:
Email
Print
The accurate measurement of the permittivity, loss tangent and dielectric anisotropy DC bias dependence for two different liquid crystal (LC) materials in the frequency range 140-165 GHz is described. The electrical characteristics are obtained by curve fitting computed transmission coefficients to the experimental spectral response of a new class of electronically reconfigurable frequency selective surface. The periodic structure is designed to yield bandpass filter characteristics with and without an applied bias control voltage in order to measure the tunability of the LC material which is inserted in a 705 µm-thick cavity.
Resumo:
The general properties of a frequency selective surface loaded with negative impedance converter (NIC)-based active loads are discussed from a theoretical perspective.The stability problem associated with NIC circuits embedded in artificial magnetic conductor (AMC) and AMC absorber applications is studied using pole-zero analysis. The requirements and constraints for achieving stable operation with enhanced bandwidth using negative capacitance as realized by a floating NIC network are derived. Furthermore, it is shown that it is nearly impossible to simultaneously implement a negative capacitor and a negative inductor to such structures. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:2111–2114, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27019
Resumo:
A V-band wide tuning-range VCO and high frequency divide-by-8 frequency divider using Infineon 0.35 µm SiGe HBT process are presented in this paper. An LC impedance peaking technique is introduced in the Miller divider to increase the sensitivity and operation frequency range of the frequency divider. Two static frequency dividers implemented using current mode logic are used to realize dividing by 4 in the circuit. The wide tuning range VCO operates from 51.9 to 64.1 GHz i.e. 20.3% frequency tuning range. The measured phase noise at the frequency divider output stage is around -98.5 dBc at 1 MHz. The circuit consumes 200mW and operates from a 3.5Vdc supply, and occupies 0.6×0.8 mm2 die area.
Resumo:
The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly-fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This paper presents a measurement based method for the early detection of power system oscillations, with attention to mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet transform and support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in different frequency bands, while SVDD is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude or that are resonant can be alarmed to the system operator, to reduce the risk of system instability. Method evaluation is exemplified used real data from a chosen wind farm.
Resumo:
The inertia of fixed-speed wind turbine generators (WTGs) helps to mitigate under-frequency transients, promotes fault ride-through and damps inter-area oscillations. It is therefore important to quantify this inertia. The authors use measured wind farm responses during under-frequency transients to provide this information. They discuss the extent of the data and the criteria used to select certain events for further analysis. The estimation of WTG inertia is based on a induction generator model. The basis of the model will be described. The manner in which the model is applied to estimate the inertia from the measured data is then explained. Finally, the implications of the results for power system operation are assessed.
Resumo:
We show that a significant increase in the gain and front-to-back ratio is obtained when different high impedance surface (HIS) sections are placed below the active regions of an Archimedean spiral antenna. The principle of operation is demonstrated at 3, 6, and 9 GHz for an antenna design that employs a ground plane composed of two dissimilar HISs. The unit cells of the HISs are collocated and resonant at the same frequency as the 3- and 6-GHz active regions of the wideband spiral. It is shown that the former HIS must also be designed to resonate at 9 GHz to avoid the generation of a boresight null that occurs because the structure is physically large enough to support higher-order modes. The improvement that is obtained at each of the three frequencies investigated is shown by comparing the predicted and measured radiation patterns for the free space and HIS-backed antenna.
Resumo:
A new variant of Class-EF power amplifier (PA), the so-called third-harmonic-peaking Class-EF, is presented. It inherits a soft-switching operation from the Class-E PA and a low peak switch voltage from the Class-F PA. More importantly, the new topology allows operations at higher frequencies and permits deployment of large transistors which is normally prohibited since they are always accompanied with high output capacitances. Using a simple transmission-line load network, the PA is synthesized to satisfy Class-EF impedances at fundamental frequency, third harmonic, and all even harmonics as well as to simultaneously provide an impedance matching to 50-Ω load.
High-Efficiency Harmonic-Peaking Class-EF Power Amplifiers with Enhanced Maximum Operating Frequency
Resumo:
The recently introduced Class-EF power amplifier (PA) has a peak switch voltage lower than that of the Class-E PA. However, the value of the transistor output capacitance at high frequencies is typically larger than the required Class-EF optimum shunt capacitance. Consequently, soft-switching operation that minimizes power dissipation during off-to-on transition cannot be achieved at high frequencies. Two new Class-EF PA variants with transmission-line load networks, namely, third-harmonic-peaking (THP) and fifth-harmonic-peaking (FHP) Class-EF PAs are proposed in this paper. These permit operation at higher frequencies at no expense to other PA figures of merit. Analytical expressions are derived in order to obtain circuit component values, which satisfy the required Class-EF impedances at fundamental frequency, all even harmonics, and the first few odd harmonics as well as simultaneously providing impedance matching to a 50- Ω load. Furthermore, a novel open-circuit and shorted stub arrangement, which has substantial practical benefits, is proposed to replace the normal quarter-wave line connected at the transistor's drain. Using GaN HEMTs, two PA prototypes were built. Measured peak drain efficiency of 91% and output power of 39.5 dBm were obtained at 2.22 GHz for the THP Class-EF PA. The FHP Class-EF PA delivered output power of 41.9 dBm with 85% drain efficiency at 1.52 GHz.
Resumo:
In this letter, a multiantenna system with four printed monopoles is presented. The monopoles that occupy relatively small area are positioned at the four corners of a printed circuit board, so that the four-element antenna system can be equipped on the lid of a folder-type mobile phone, leaving enough space for the circuits and reducing the effect of human hands. Based on simulation, a prototype for the Universal Mobile Telecommunications System (UMTS) operation has been constructed and tested. The measured -10-dB impedance bandwidths of the four elements are larger than 320 MHz with higher than 11.5-dB isolation. Moreover, the proposed antenna can provide spatial and pattern diversity in a diversity/multiple-input-multiple-output (MIMO) system.
Resumo:
High impedance metasurfaces (HIMSs) formed by interwoven conductor arrays are proposed. Bandwidth comparable with that of the basic square patches is achieved at an order of magnitude smaller unit cells. The presented structures are apt for small mobile terminals and low frequency applications.
Resumo:
This letter presents the design of a thin microwave absorber which exhibits a -10 dB reflectivity bandwidth of 108% at normal incidence and 16% for simultaneous suppression of TE and TM polarised waves over the angular range 0-45° is presented. The structure consists of a 3 mm-thick metal backed frequency selective surface (FSS) with four resistively loaded hexagonal loop elements in each unit cell. The surface resistivity and width of the loops are carefully chosen to maximise the bandwidth by merging the reflection nulls that are generated by the multi-resonant absorber. Measurement and simulation results are in good agreement over the broad frequency range 7.8-24 GHz.
Resumo:
The Consideration of Future Consequences construct has been found to relate meaningfully to several positive outcomes in temporal research. Researchers have proposed 1-factor, 2-factor, and bifactor solutions to the Consideration of Future Consequences Scale (CFCS). Using 313 British University undergraduates, we tested four competing models: (a) a 12-item unidimensional model, (b) a model fitted for two uncorrelated factors (CFC-Immediate and CFC-Future), (c) a model fitted for two correlated factors (CFC-I and CFC-F), and (d) a bifactor model. Results supported the bifactor model, suggesting that the two hypothesized factors are better understood as grouping factors. Accordingly, the present study supports the CFCS as a unidimensional global future orientation measure. These results have important implications for the study of future orientation using the CFCS. Researchers using the CFCS are encouraged to examine a bifactor solution for the scores.
Resumo:
The southern industrial rivers (Aire, Calder, Don and Trent) feeding the Humber estuary were routinely monitored for a range of chlorinated micro- organic contaminants at least once a week over a 1.5-year period. Environmental Quality Standards (EQSs) for inland waters were set under the European Economic Community for a limited number of problematic contaminants (18). The results of the monitoring program for seven classes of chlorinated pollutants on the EQS list are presented in this study. All compounds were detected frequently with the exception of hexachlorobutadiene (where only one detectable measurement out of 280 individual samples occurred). In general, the rivers fell into two classes with respect to their contamination patterns. The Aire and Calder carried higher concentrations of micro- pollutants than the Don and Trent, with the exception of hexachlorobenzene (HCB). For Σ hexachlorocyclohexane (HCH) isomers (α + γ) and for dieldrin, a number of samples (~ 5%) exceeded their EQS for both the Aire and Calder. Often, ΣHCH concentrations were just below the EQS level. Levels of p,p'- DDT on occasions approached the EQS for these two rivers, but only one sample (out of 140) exceeded the EQS. No compounds exceeded their EQS levels on the Don and Trent. Analysis of the ratio of γ HCH/αHCH indicated that the source of HCH for the Don and Trent catchments was primarily lindane (γHCH) and, to a lesser extent, technical HCH (mixture of HCH isomers, dominated by α HCH), while the source(s) for the Aire and Calder had a much higher contribution from technical HCH.
Resumo:
Ex vivo T cell depletion of allogeneic grafts is associated with a high (up to 80%) rate of mixed chimerism (MC) posttransplantation. The number of transplanted progenitor cells is an important factor in achieving complete donor chimerism in the T cell depletion setting. Use of granulocyte colony-stimulating factor (G-CSF) peripheral blood allografts allows the administration of large numbers of CD34+ cells. We studied the chimeric status of 13 patients who received allogeneic CD34+-selected peripheral blood progenitor cell transplants (allo-PBPCTs/CD34+) from HLA-identical sibling donors. Patients were conditioned with cyclophosphamide (120 mg/kg) and total-body irradiation (13 Gy in four fractions). Apheresis products were T cell-depleted by the immunoadsorption avidin-biotin method. The median number of CD34+ and CD3+ cells infused was 2.8x10(6)/kg (range 1.9-8.6x10(6)/kg) and 0.4x10(6)/kg (range 0.3-1x10(6)/kg), respectively. Molecular analysis of the engraftment was performed using polymerase chain reaction (PCR) amplification of highly polymorphic short tandem repeat (PCR-STR) sequences in peripheral blood samples. MC was detected in two (15%) of 13 patients. These two patients relapsed at 8 and 10 months after transplant, respectively. The remaining 11 patients showed complete donor chimerism and were in clinical remission after a maximum follow-up period of 24 months (range 6-24 months). These results were compared with those obtained in 10 patients who were treated with T cell-depleted bone marrow transplantation by means of elutriation and who received the same conditioning treatment and similar amounts of CD3+ cells (median 0.45x10(6)/kg; not significant) but a lower number of CD34+ cells (median 0.8x10(6)/kg; p = 0.001). MC was documented in six of 10 patients (60%), which was significantly higher than in the allo-PBPCT/CD34+ group (p = 0.04). We conclude that a high frequency of complete donor chimerism is achieved in patients receiving allo-PBPCT/CD34+ and that this is most likely due to the high number of progenitor cells administered.