303 resultados para Delivery (Obstetrics)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates the polyanion initiated gelation process in fabricating chitosan-TPP (tripolyphosphate) nanoparticles in the size range of 100-250 nm intended to be used as carriers for the delivery of gene or protein macromolecules. It demonstrates that ionic gelation of cationic chitosan molecules offers a flexible and easily controllable process for systematically and predictably manipulating particle size and surface charge which are important properties in determining gene transfection efficacy if the nanoparticles are used as non-viral vectors for gene delivery, or as delivery carriers for protein molecules. Variations in chitosan molecular weight, chitosan concentration, chitosan to TPP weight ratio and solution pH value were examined systematically for their effects on nanoparticle size, intensity of surface charge, and tendency of particle aggregation so as to enable speedy fabrication of chitosan nanoparticles with predetermined properties. The chitosan-TPP nanoparticles exhibited a high positive surface charge across a wide pH range, and the isoelectric point (IEP) of the nanoparticles was found to be at pH 9.0. Detailed imaging analysis of the particle morphology revealed that the nanoparticles possess typical shapes of polyhedrons (e.g., pentagon and hexagon), indicating a similar crystallisation mechanism during the particle formation and growth process. This study demonstrates that systematic design and modulation of the surface charge and particle size of chitosan-TPP nanoparticles can be readily achieved with the right control of critical processing parameters, especially the chitosan to TPP weight ratio. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conducting polypyrrole is a biological compatible polymer matrix wherein number of drugs and enzymes can be incorporated by way of doping. The polypyrrole, which is obtained as freestanding film by electrochemical polymerization, has gained tremendous recognition as sophisticated electronic measuring device in the field of sensors and drug delivery. In drug delivery the reversing of the potential 100% of the drug can be released and is highly efficient as a biosensor in presence of an enzyme. In this review we discuss the applications of conducting polypyrrole as biosensor for some biomolecules and drug delivery systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodynamic therapy of deep or nodular skin tumours is currently limited by the poor tissue penetration of the porphyrin precursor 5-aminolevulinic acid (ALA). In this study, silicon microneedle arrays were used, for the first time, to enhance skin penetration of ALA in vitro and in vivo. Puncturing excised murine skin with 6x7 arrays of microneedles 270 mum in height, with a diameter of 240 mum at the base and an interspacing of 750 mum led to a significant increase in transdermal delivery of ALA released from a bioadhesive patch containing 19 mg ALA cm(-2). Microneedle puncture enhanced ALA delivery to the upper regions of excised porcine skin but, at mean depths of 1.875 mm, ALA concentrations were similar to control values, possibly reflecting binding of ALA by tissue components. However, and importantly, in vivo experiments using nude mice showed that microneedle puncture could reduce application time and ALA dose required to induce high levels of the photosensitiser protoporphyrin IX in skin. This clearly has implications for clinical practice, as shorter application times would mean improved patient and clinician convenience and also that more patients could be treated in the same session. As ALA is expensive and degrades rapidly via a second order reaction, reducing the required dose is also a notable advantage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of review: The aim of this article is to summarize the latest information on microbicide formulations for prevention of sexual transmission of HIV infection in women. Recent findings: Although early microbicide formulations were conventionally coitally dependent gel products, new technologies are being developed for vaginal delivery of anti-HIV agents. Intravaginal rings for delivery of microbicides, for example, are being developed and evaluated clinically. Safety and acceptability data are available for many microbicide gels and for one microbicide intravaginal ring. Other microbicide formulations in development for once daily or other vaginal administration strategies include films, tablets, and ovules. Various microbicide formulations for rectal administration are also in development. Summary: New microbicide formulations in development are addressing many of the issues with the original gels such as coital dependency, frequency of use, acceptability, compliance, cost, and adaptability to large-scale production. All of these dosage forms are promising options for safe, effective, and acceptable microbicide products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaginal microbicides for the prevention of HIV transmission may be an important option for protecting women from infection. Incorporation of dapivirine, a lead candidate nonnucleoside reverse transcriptase inhibitor, into intravaginal rings (IVRs) for sustained mucosal delivery may increase microbicide product adherence and efficacy compared with conventional vaginal formulations. Twentyfour
healthy HIV-negative women 18–35 years of age were randomly assigned (1:1:1) to dapivirine matrix IVR, dapivirine reservoir IVR, or placebo IVR. Dapivirine concentrations were measured in plasma
and vaginal fluid samples collected at sequential time points over the 33-day study period (28 days of IVR use, 5 days of follow-up). Safety was assessed by pelvic/colposcopic examinations, clinical laboratory tests, and adverse events. Both IVR types were safe and well tolerated with similar adverse events observed in the placebo and dapivirine groups. Dapivirine from both IVR types was successfully distributed throughout the lower genital tract at concentrations over 4 logs greater than the EC50 against wild-type HIV-1 (LAI) in MT4 cells. Maximum concentration (Cmax) and area under the concentration–time curve (AUC) values were significantly higher with the matrix than reservoir IVR. Mean plasma concentrations of dapivirine were ,2 ng/mL. These findings suggest that IVR delivery of microbicides is a viable option meriting further study.

Relevância:

20.00% 20.00%

Publicador: