52 resultados para Aberdeen Angus


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most tutors in architecture education regard studio-based learning to be rich in feedback due to is dialogic nature. Yet, student perceptions communicated via audits such as the UK National Student Survey appear to contradict this assumption and challenge the efficacy of design studio as a truly discursive learning setting. This paper presents findings from a collaborative study that was undertaken by the Robert Gordon University, Aberdeen, and Queen’s University Belfast that develop a deeper understanding of the role that peer interaction and dialogue plays within feedback processes, and the value that students attribute to these within the overall learning experience.

The paper adopts a broad definition of feedback, with emphasis on formative processes, and including the various kinds of dialogue that typify studio-based learning, and which constitute forms of guidance, direction, and reflection. The study adopted an ethnographic approach, gathering data on student and staff perceptions over the course of an academic year, and utilising methods embracing both quantitative and qualitative data.

The study found that the informal, socially-based peer interaction that characterises the studio is complementary to, and quite distinct from, the learning derived through tutor interaction. The findings also articulate the respective properties of informal and formally derived feedback and the contribution each makes to the quality of studio-based learning. It also identifies limitations in the use or value of peer learning, understanding of which is valuable to enhancing studio learning in architecture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report presents the results of a collaborative project between Queens University, Belfast and the Robert Gordon University, Aberdeen, and builds on a dialogue initiated during Session 2009-10 through which course guidance and feedback received by students was identified as an area requiring deeper understanding in order to enhance current practice

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of socio-economic factors on visual acuity (VA) at presentation in exudative age- related macular degeneration (AMD). Methods: The medical records of all consecutive patients with newly diagnosed exudative AMD examined at the Ophthalmology Departments of Grampian University Hospitals-NHS Trust, Aberdeen, and Gartnavel General Hospital, Glasgow, between July 2004 and June 2005, were reviewed. Demographics, duration of symptoms, VA in study and fellow eye, exudative AMD characteristics, status of fellow eye and patient home address, used to determine the Scottish Index of Multiple Deprivation (SIMD) score, were recorded. The effect of these parameters on VA at presentation was investigated using general linear modelling. Results: Two-hundred and forty patients (median age 79 years) were included in this study; 44 (18.3%) belonged to the lowest 20% SIMD score (most deprived). Age and location and type of the choroidal neovascular- isation were statistically significantly associated with VA at presentation (p = 0.003, p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conflicting results have been reported on the detection of paramyxovirus transcripts in Paget's disease, and a possible explanation is differences in the sensitivity of RT-PCR methods for detecting virus. In a blinded study, we found no evidence to suggest that laboratories that failed to detect viral transcripts had less sensitive RT-PCR assays, and we did not detect measles or distemper transcripts in Paget's samples using the most sensitive assays evaluated.

Introduction: There is conflicting evidence on the possible role of persistent paramyxovirus infection in Paget's disease of bone (PDB). Some workers have detected measles virus (MV) or canine distemper virus (CDV) transcripts in cells and tissues from patients with PDB, but others have failed to confirm this finding. A possible explanation might be differences in the sensitivity of RT-PCR methods for detecting virus. Here we performed a blinded comparison of the sensitivity of different RT-PCR-based techniques for MV and CDV detection in different laboratories and used the most sensitive assays to screen for evidence of viral transcripts in bone and blood samples derived from patients with PDB.

Materials and Methods: Participating laboratories analyzed samples spiked with known amounts of MV and CDV transcripts and control samples that did not contain viral nucleic acids. All analyses were performed on a blinded basis.

Results: The limit of detection for CDV was 1000 viral transcripts in three laboratories (Aberdeen, Belfast, and Liverpool) and 10,000 transcripts in another laboratory (Manchester). The limit of detection for MV was 16 transcripts in one laboratory (NIBSC), 1000 transcripts in two laboratories (Aberdeen and Belfast), and 10,000 transcripts in two laboratories (Liverpool and Manchester). An assay previously used by a U.S.-based group to detect MV transcripts in PDB had a sensitivity of 1000 transcripts. One laboratory (Manchester) detected CDV transcripts in a negative control and in two samples that had been spiked with MV. None of the other laboratories had false-positive results for MV or CDV, and no evidence of viral transcripts was found on analysis of 12 PDB samples using the most sensitive RT-PCR assays for MV and CDV.

Conclusions: We found that RT-PCR assays used by different laboratories differed in their sensitivity to detect CDV and MV transcripts but found no evidence to suggest that laboratories that previously failed to detect viral transcripts had less sensitive RT-PCR assays than those that detected viral transcripts. False-positive results were observed with one laboratory, and we failed to detect paramyxovirus transcripts in PDB samples using the most sensitive assays evaluated. Our results show that failure of some laboratories to detect viral transcripts is unlikely to be caused by problems with assay sensitivity and highlight the fact that contamination can be an issue when searching for pathogens by sensitive RT-PCR-based techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting) should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items) that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology.

METHODS: The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ). The five steps are: 1) Generation of a pool of items; 2) Item de-duplication (three phases); 3) Item reduction (two phases); 4) Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF); and 5) qualitative exploration of the target populations' views of the new instrument and the items it contains.

RESULTS: The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study) resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items.

CONCLUSIONS: This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped after the item generation phase, our method ensures that the AGQ is developed in a transparent, replicable manner and is fit for validation. We recommend this method to enhance the likelihood that new PRO instruments will be appropriate to the research context in which they are used, acceptable to research participants and likely to generate valid data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of socio-economic factors on severity of glaucoma at presentation

METHODS: All newly diagnosed glaucoma patients at the University Hospitals-NHS, Aberdeen and South Glasgow University Hospitals-NHS, in 2006, were included. Glaucoma was severe at presentation if there was a repeatable visual-field loss with a mean deviation index greater than 12 dB in the Humphreys visual fields test or an absolute paracentral scotoma within the central 5 degrees of the visual fields. Home address was used to determine the Scottish Index of Multiple Deprivation (SIMD) rank. The SIMD rank, demographics and severity of glaucoma at presentation were investigated using general linear modelling.

RESULTS: There were 48 patients with severe glaucoma and 74 patients with non-severe glaucoma. In four, the severity could not be determined. Severity of glaucoma at presentation was significantly associated with SIMD rank, being most severe in patients from areas with the lowest ranks (p = 0.026). Age was a significant factor (p = 0.024), with severe glaucoma being more common in elderly patients.

CONCLUSIONS: Age and socio-economic deprivation were associated with severity of glaucoma at presentation, with patients from areas of higher socio-economic deprivation presenting with more advanced glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. ?Methods: The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. ?Results: A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (?2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). ?Conclusion: Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Research investigating the association between negative symptoms and plasma cortisol levels in individuals with schizophrenia has produced inconsistent findings. This study investigated whether deficit syndrome schizophrenia (characterized by high levels of primary negative symptoms) is associated with comparatively high morning plasma cortisol levels, more negative appraisals about illness and higher levels of depression. Participants were 85 individuals diagnosed with schizophrenia and 85 individuals with no history of contact with psychiatric services matched for age and gender. All participants provided fasting 9.00 a.m. plasma cortisol samples. There were no significant differences between the schizophrenia and control participants in plasma cortisol levels. The Proximal Deficit Syndrome method was used to identify individuals with deficit syndrome schizophrenia. Contrary to what had been hypothesized, participants with deficit syndrome schizophrenia had significantly lower plasma cortisol levels than both non-deficit syndrome participants and control participants. Participants with the deficit syndrome reported significantly less negative appraisals about illness (assessed by PBIQ) and lower levels of depression (assessed by BDI-II). Differences in cortisol levels continued to trend toward significance when levels of depression were controlled for. The patterns of illness-related appraisals and plasma cortisol levels raise the possibility that the deficit syndrome could be a form of adaptation syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the first planet discovery from the two-wheeled Kepler (K2) mission: HIP 116454 b. The host star HIP 116454 is a bright (V = 10.1, K = 8.0) K1 dwarf with high proper motion and a parallax-based distance of 55.2 +/- 5.4 pc. Based on high-resolution optical spectroscopy, we find that the host star is metal-poor with [Fe/H]= -0.16 +/- 0.08 and has a radius R-star = 0.716 +/- 0.024 R-circle dot and mass M-star = 0.775 +/- 0.027M(circle dot). The star was observed by the Kepler spacecraft during its Two-Wheeled Concept Engineering Test in 2014 February. During the 9 days of observations, K2 observed a single transit event. Using a new K2 photometric analysis technique, we are able to correct small telescope drifts and recover the observed transit at high confidence, corresponding to a planetary radius of R-p = 2.53 +/- 0.18 R-circle plus. Radial velocity observations with the HARPS-N spectrograph reveal a 11.82 +/- 1.33 M-circle plus planet in a 9.1 day orbit, consistent with the transit depth, duration, and ephemeris. Follow-up photometric measurements from the MOST satellite confirm the transit observed in the K2 photometry and provide a refined ephemeris, making HIP 116454 b amenable for future follow-up observations of this latest addition to the growing population of transiting super-Earths around nearby, bright stars.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novel nucleoside analogues containing photoswitchable moieties were prepared using 'click' cycloaddition reactions between 5 '-azido-5 '-deoxythymidine and mono- or bis-N-propargylamide-substituted azobenzenes. In solution, high to quantitative yields were achieved using 5mol% Cu(I) in the presence of a stabilizing ligand. 'Click' reactions using the monopropargylamides were also effected in the absence of added cuprous salts by the application of liquid assisted grinding (LAG) in metallic copper reaction vials. Specifically, high speed vibration ball milling (HSVBM) using a 3/32('') (2.38mm) diameter copper ball (62mg) at 60Hz overnight in the presence of ethyl acetate lead to complete consumption of the 5 '-azido nucleoside with clean conversion to the corresponding 1,3-triazole.