66 resultados para (acidified sample)
Resumo:
Background: In occupational life, a mismatch between high expenditure of effort and receiving few rewards may promote the co-occurrence of lifestyle risk factors, however, there is insufficient evidence to support or refute this hypothesis. The aim of this study is to examine the extent to which the dimensions of the Effort-Reward Imbalance (ERI) model - effort, rewards and ERI - are associated with the co-occurrence of lifestyle risk factors.
Resumo:
Regulatory authorities, the food industry and the consumer demand reliable determination of chemical contaminants present in foods. A relatively new analytical technique that addresses this need is an immunobiosensor based on surface plasmon resonance (SPR) measurements. Although a range of tests have been developed to measure residues in milk, meat, animal bile and honey, a considerable problem has been encountered with both serum and plasma samples. The high degree of non-specific binding of some sample components can lead to loss of assay robustness, increased rates of false positives and general loss of assay sensitivity. In this paper we describe a straightforward precipitation technique to remove interfering substances from serum samples to be analysed for veterinary anthelmintics by SPR. This technique enabled development of an assay to detect a wide range of benzimidazole residues in serum samples by immunobiosensor. The limit of quantification was below 5 ng/ml and coefficients of variation were about 2%.
Resumo:
Immunoaffinity chromatography (IAC) and affinity chromatography (AC:) are widely used for extraction of drugs from biological samples. Fifteen column types were purchased from five different manufacturers and;their ability to bind specific drugs including beta-agonists and anabolic steroids over a range of analyte concentrations in fortified bovine urine samples was assessed. The performance data obtained from these columns were compared with columns produced in this laboratory (in house columns). The in house columns gave the highest recoveries, ranging from 92 to 100% at the 1 ng spiking concentration, for five of the seven analytes assessed. Forty percent (11 of 27) of all the commercial column assessments recorded recoveries of less than 50% even when the lowest spiking concentration was applied (1 ng). For one manufacturer, only one of seven different columns purchased delivered extraction efficiencies greater than 50%. The extraction efficiencies of the clenbuterol columns were the highest with all commercially prepared columns showing at least 50% binding of radiolabelled tracer. Recoveries of alpha-nortestosterone were the lowest. The variability of these products with respect to quality control requires constant monitoring.
Resumo:
The characterisation of soils for civil engineering purposes depends on removing sufficiently high-quality samples from the ground. Accurate evaluation of sample quality is therefore important if reliable design parameters are to be determined. This paper describes the use of unconfined shear wave velocity (V s) and suction (u r) measurements to assess sample quality rapidly in soft clay. Samples of varying quality from three well-characterised soft clay sites are initially assessed using conventional techniques, and their results compared with V s and u r measurements performed on the same samples. It is observed that the quality of samples indicated by these measurements is very similar to those inferred from traditional disturbance measures, with V s being the more reliable indicator. A tentative empirically derived criterion, based on samples tested in this project, is proposed to quantify sample disturbance combining both V s and u r measurements. Further work using this criterion on different materials is important so as to test its usefulness.
Resumo:
A genomewide linkage scan was carried out in eight clinical samples of informative schizophrenia families. After all quality control checks, the analysis of 707 European-ancestry families included 1615 affected and 1602 unaffected genotyped individuals, and the analysis of all 807 families included 1900 affected and 1839 unaffected individuals. Multipoint linkage analysis with correction for marker-marker linkage disequilibrium was carried out with 5861 single nucleotide polymorphisms (SNPs; Illumina version 4.0 linkage map). Suggestive evidence for linkage ( European families) was observed on chromosomes 8p21, 8q24.1, 9q34 and 12q24.1 in nonparametric and/or parametric analyses. In a logistic regression allele-sharing analysis of linkage allowing for intersite heterogeneity, genomewide significant evidence for linkage was observed on chromosome 10p12. Significant heterogeneity was also observed on chromosome 22q11.1. Evidence for linkage across family sets and analyses was most consistent on chromosome 8p21, with a one-LOD support interval that does not include the candidate gene NRG1, suggesting that one or more other susceptibility loci might exist in the region. In this era of genomewide association and deep resequencing studies, consensus linkage regions deserve continued attention, given that linkage signals can be produced by many types of genomic variation, including any combination of multiple common or rare SNPs or copy number variants in a region. Molecular Psychiatry (2009) 14, 786-795; doi:10.1038/mp.2009.11; published online 17 February 2009
Resumo:
A sensitive and specific monoclonal ELISA for the determination of tissue bound furazolidone metabolite 3-amino-2-oxazolidinone (AOZ) is described. The procedure enables the detection of AOZ in matrix supernatant after homogenisation, protease treatment, acid hydrolysis and derivatisation of AOZ released from the tissue by o-nitrobenzaldehyde. The formed p-nitrophenyl 3-amino-2-oxazolidinone (NPAOZ) is determined by ELISA calibrated with matrix-matched standards in the concentration range of 0.05-5.0 mu g l(-1). The assay was validated according to criteria set down by Commission Decision 2002/657/EC for the performance and validation of analytical methods for chemical residues. Detection capability, set on the basis of acceptance of no false negative results, was 0.4 mu g kg(-1) for shrimp, poultry, beef and pork muscle. This sensitivity approaches the established confirmatory LC-MS/MS able to quantify tissue-bound AOZ at levels as low as 0.3 mu g kg(-1). An excellent correlation of results obtained by ELISA and LC/MS-MS within the concentration range 0-32.1 mu g kg(-1) was found in the naturally contaminated shrimp samples (r = 0.999, n = 8). A similar con-elation was found for the incurred poultry samples within the concentration range of 0-10.5 mu g kg(-1) (r = 0.99, n = 8). (c) 2005 Elsevier B.V All rights reserved.
Resumo:
One of the most important bird breeding and over wintering sites in the west of Europe, the Coto Doñana, was severely impacted by the release of 5 million cubic meters of acid waste from the processing of pyrite ore. The waste entered ecologically sensitive areas of the park (including breeding areas for internationally endangered bird species) causing sustained pH decreases from pH 8.5 to 4.5 and resulting in massive metal contamination of the impacted ecosystem. The contaminating sludge waste contained arsenic at 0.6%, lead at 1.2% and zinc at 0.8% on a dry weight basis. The acid conditions facilitated the solubilization of these metals, leading to water concentrations lethal for aquatic wildlife. The accident caused considerable fish and invertebrate kills and has severe consequences for the protected bird species dependent on the impacted habitats and adjacent areas.
Resumo:
The Temporal Focus Scale (TFS) is a 12-item self-report measure of cognitive engagement with the temporal domains of past, present and future. Developed in college student samples, a three-factor structure with adequate reliability and validity was documented in a series of independent studies. We tested the factor structure of the scale in a sample of Northern Irish adolescents and found that our data supported a three factor structure, although there were problems with item 10. Because time perspective measures have been found to relate differentially to various health behaviours, we tested the relations between scores on the TFS and self-reported alcohol use. Results showed that scores on the TFS were not consistent statistical predictors of drinking category in a logistic regression. Results are discussed in terms of scale development, future scale use and the assessment of health-compromising behaviours such as adolescent alcohol consumption. © 2012 The Foundation for Professionals in Services for Adolescents.
Resumo:
The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78ngmL and the CCß to be 1ngmL. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1ngmL, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1ngmL. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1µgL. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.