208 resultados para prime k-tuples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This single center study is the largest series of renal transplant recipients and donors screened for the commonest prothrombotic genotypes. A total of 562 transplant recipients and 457 kidney donors were genotyped for the factor V Leiden and prothrombin G20210A mutations. The prevalence of heterozygous factor V Leiden was 3.4% and 2.6% and prothrombin G20210A was 2.0% and 1.1% in recipients and donors, respectively, similar frequencies to that of the general U.K. population. The 30-day and 1-year graft survival rates in recipients with thrombophilic mutations were 93% and 93%, compared with 88% and 82% in patients without these mutations (log-rank P =0.34). Thrombophilia in recipients (odds ratio 0.55; confidence interval 0.06-2.29; P =0.56) or in donors (odds ratio 1.53; confidence interval 0.27-5.74; P =0.46) did not correlate with graft loss at 30 days after transplantation. In contrast to recent reports, this study did not demonstrate an association between thrombophilia and renal allograft loss, and routine screening is not recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The perforated-patch technique was used to measure membrane currents in smooth muscle cells from sheep urethra. Depolarizing pulses evoked large transient outward currents and several components of sustained current. The transient current and a component of sustained current were blocked by iberiotoxin, penitrem A, and nifedipine but were unaffected by apamin or 4-aminopyridine, suggesting that they were mediated by large-conductance Ca(2+)-activated K(+) (BK) channels. When the BK current was blocked by exposure to penitrem A (100 nM) and Ca(2+)-free bath solution, there remained a voltage-sensitive K(+) current that was moderately sensitive to blockade with tetraethylammonium (TEA; half-maximal effective dose = 3.0 +/- 0.8 mM) but not 4-aminopyridine. Penitrem A (100 nM) increased the spike amplitude and plateau potential in slow waves evoked in single cells, whereas addition of TEA (10 mM) further increased the plateau potential and duration. In conclusion, both Ca(2+)-activated and voltage-dependent K(+) currents were found in urethral myocytes. Both of these currents are capable of contributing to the slow wave in these cells, suggesting that they are likely to influence urethral tone under certain conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract In the theory of central simple algebras, often we are dealing with abelian groups which arise from the kernel or co-kernel of functors which respect transfer maps (for example K-functors). Since a central simple algebra splits and the functors above are “trivial” in the split case, one can prove certain calculus on these functors. The common examples are kernel or co-kernel of the maps Ki(F)?Ki(D), where Ki are Quillen K-groups, D is a division algebra and F its center, or the homotopy fiber arising from the long exact sequence of above map, or the reduced Whitehead group SK1. In this note we introduce an abstract functor over the category of Azumaya algebras which covers all the functors mentioned above and prove the usual calculus for it. This, for example, immediately shows that K-theory of an Azumaya algebra over a local ring is “almost” the same as K-theory of the base ring. The main result is to prove that reduced K-theory of an Azumaya algebra over a Henselian ring coincides with reduced K-theory of its residue central simple algebra. The note ends with some calculation trying to determine the homotopy fibers mentioned above.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel technology dependent scaling parameters i.e. spacer to gradient ratio and effective channel length (Leff) are proposed for source/drain engineered DG MOSFET, and their significance in minimizing short channel effects (SCES) in high-k gate dielectrics is discussed in detail. Results show that a high-k dielectric should be associated with a higher spacer to gradient ratio to minimise SCEs The analytical model agrees with simulated data over the entire range of spacer widths, doping gradients, high-k gate dielectrics and effective channel lengths.