142 resultados para geometric arrays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient modelling technique is proposed for the analysis of a fractal-element electromagnetic band-gap array. The modelling is based on a method of moments modal analysis in conjunction with an interpolation scheme, which significantly accelerates the computations. The plane-wave and the surface-wave responses of the structure have been studied by means of transmission coefficients and dispersion diagrams. The multiband properties and the compactness of the proposed structure are presented. The technique is general and can be applied to arbitrary-shaped element geometries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Published ab-initio and pseudopotential calculations for the dialkali halide systems suggest that the preferred co-linear geometry is for the metal to approach the metal end of the alkali halide. Here, ab-initio calculations on the Li2F system reveal that the well depth on the halide side in this radical is much deeper and is a local saddle-point associated with the ionic non-linear global minima. Although many features of the pseudopotential surfaces are confirmed, significant differences are apparent including the existence of a linear excited state instead of a triangular one, a considerably deeper global minimum some 50% lower in energy and a close approach between the X2A1 and the states, with the minimum 87 kJ mol-1 below the ground state asymptote. All the results can be rationalised as the avoided crossings between a long range, covalent potential dominant within the LiLiF geometry and an ionic state that forms the global minimum. Calculations on the 3rd 2A' potential indicate that even for Li + LiF collisions at ultracold temperatures the collision dynamics could involve as many as three electronic states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Margins are used in radiotherapy to assist in the calculation of planning target volumes. These margins can be determined by analysing the geometric uncertainties inherent to the radiotherapy planning and delivery process. An important part of this process is the study of electronic portal images collected throughout the course of treatment. Set-up uncertainties were determined for prostate radiotherapy treatments at our previous site and the new purpose-built centre, with margins determined using a number of different methods. In addition, the potential effect of reducing the action level from 5 mm to 3 mm for changing a patient set-up, based on off-line bony anatomy-based portal image analysis, was studied. Margins generated using different methodologies were comparable. It was found that set-up errors were reduced following relocation to the new centre. Although a significant increase in the number of corrections to a patient's set-up was predicted if the action level was reduced from 5 mm to 3 mm, minimal reduction in patient set-up uncertainties would be seen as a consequence. Prescriptive geometric uncertainty analysis not only supports calculation and justification of the margins used clinically to generate planning target volumes, but may also best be used to monitor trends in clinical practice or audit changes introduced by new equipment, technology or practice. Simulations on existing data showed that a 3 mm rather than a 5 mm action level during off-line, bony anatomy-based portal imaging would have had a minimal benefit for the patients studied in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed to accelerate the evaluation of the Green's function of an infinite double periodic array of thin wire antennas. The method is based on the expansion of the Green's function into series corresponding to the propagating and evanescent waves and the use of Poisson and Kummer transformations enhanced with the analytic summation of the slowly convergent asymptotic terms. Unlike existing techniques the procedure reported here provides uniform convergence regardless of the geometrical parameters of the problem or plane wave excitation wavelength. In addition, it is numerically stable and does not require numerical integration or internal tuning parameters, since all necessary series are directly calculated in terms of analytical functions. This means that for nonlinear problem scenarios that the algorithm can be deployed without run time intervention or recursive adjustment within a harmonic balance engine. Numerical examples are provided to illustrate the efficiency and accuracy of the developed approach as compared with the Ewald method for which these classes of problems requires run time splitting parameter adaptation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper starts presents the work initially carried out by Queen's University and RSRE (now Qinetiq) in the development of advanced architectures and microchips based on systolic array architectures. The paper outlines how this has led to the development of highly complex designs for high definition TV and highlights work both on advanced signal processing architectures and tool flows for advanced systems. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods: In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models.

Results: When employing Silescol® membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol® membranes in the corresponding experiments. Approximately 103?cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case.

Conclusion: We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle—punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A structure comprising a coupled pair of two-dimensional arrays of oblate plasmonic nanoellipsoids in a dielectric host medium is proposed as a superlens in the optical domain for both horizontal and vertical polarizations. By means of simulations it is demonstrated that a structure formed by silver nanoellipsoids is capable of restoring subwavelength features of the object for both polarizations at distances larger than half wavelength. The bandwidth of subwavelength resolution is in all cases very large (above 13%). (C) 2009 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical modeling approach for the prediction of the geometric characteristics of five-dimensional (5D) woven composites has been formulated. The model is driven by readily available data including the weaving parameters and constituent material properties. The new model calculates the individual proportions of fiber in each direction, areal density, overall fiber volume fraction, and laminate thickness. This information is useful for the engineer in the design and manufacture of 5D woven composites. In addition the present model outputs the mathematical definition of the 5D woven composite unit cell, which could be implemented as the geometric input for a downstream analytical model that is capable of predicting the elastic stiffness of 5D woven composites. Input parameters have been sourced from existing published work and the subsequent predictions made by the model are compared with the available experimental data on 5D woven composites.