We induced choroidal neovascularization in the rhesus monkey by impoverishing the blood supply to the inner retina and producing defects in Bruch's membrane by photocoagulation. Fourteen of 46 eyes undergoing photocoagulation developed neovascular fronds which were identified and categorized by histopathologic examination and fluorescein angiography. All new vessels gained access to the retina through defects in Bruch's membrane at the site of photocoagulation marks. In eight eyes the new vessels remained localized to the immediate vicinity of photocoagulation marks. In four eyes neovascular fronds infiltrated the subretinal space for distances up to 6 disk diameters from the point of entry into the retina. In the two eyes choroidovitreal neovascular complexes developed but rapidly regressed shortly after gaining the vitreous cavity. Fluorescein angiography demonstrated that all neovascular fronds were grossly incompetent to dye but that formed feeding channels had some degree of integrity. Light microscopic studies showed the proliferating networks to be composed of capillaries with well-formed basement membranes and more mature vessels with the basic structure of choroidal arteries and veins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical and histological side effects of a prototype stereotactic radiotherapy system delivering microcollimated external beam radiation through pars plana in porcine eyes.

Methods: Five Yucatan mini-swine (10 eyes) were randomized to five treatment groups. Eight eyes were dosed with X-ray radiation on Day 1, and two eyes served as untreated controls. Treated eyes received doses up to 60 Gy to the retina and up to 130 Gy to the sclera using single or overlapping beams. The treatment beams were highly collimated such that the diameter was approximately 2.5 mm on the sclera and 3 mm on the retinal surface. Fundus photography, fluorescein angiography (FA), and spectral domain optical coherence tomography (SD-OCT) were obtained on days 7, 30, 60, and 110. Images were examined by a masked grader and evaluated for abnormalities. Animals were sacrificed on day 111 and gross and histopathological analysis was conducted.

Results: Histological and gross changes to eye structures including conjunctiva and lens were minimal at all doses. Fundus, FA, and SD-OCT of the targeted region failed to disclose any abnormality in the control or 21 Gy treated animals. In the 42 and 60 Gy animals, hypopigmented spots were noted after treatment on clinical exam, and corresponding hyperfluorescent staining was seen in late frames. No evidence of choroidal hypoperfusion was seen. The histological specimens from the 60 Gy animals showed photoreceptor loss and displacement of cone nuclei.

Conclusion: Transcleral stereotactic radiation dosing in porcine eyes can be accomplished with no significant adverse events as doses less than 42 Gy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study tested the role of K(+)- and Cl(-)-channels in retinal arteriolar smooth muscle in the regulation of retinal blood flow.

Methods: Studies were carried out in adult Male Hooded Lister rats. Selectivity of ion channel blockers was established using electrophysiological recordings from smooth muscle in isolated arterioles under voltage clamp conditions. Leukocyte velocity and retinal arteriolar diameters were measured in anesthetised animals using leukocyte fluorography and fluorescein angiography imaging with a confocal scanning laser ophthalmoscope. These values were used to estimate volumetric flow, which was compared between control conditions and following intravitreal injections of ion channel blockers, either alone or in combination with the vasoconstrictor potent Endothelin 1 (Et1).

Results: Voltage activated K(+)-current (IKv) was inhibited by correolide, large conductance (BK) Ca(2+)-activated K(+)-current (IKCa) by Penitrem A, and Ca(2+)-activated Cl(-)-current (IClCa) by disodium 4,4'-diisothiocyanatostilbene-2,2'-disulfonate (DIDS). Intravitreal injections (10µl) of DIDS (estimated intraocular concentration 10mM) increased flow by 22%, whereas the BK-blockers Penitrem A (1µM) and iberiotoxin (4µM), and the IKv-inhibitor correolide (40µM) all decreased resting flow by approximately 10%. Et1 (104nM) reduced flow by almost 65%. This effect was completely reversed by DIDS but was unaffected by Penitrem A, iberiotoxin or correolide.

Conclusions: These results suggest that Cl(-)-channels in retinal arteriolar smooth muscle limit resting blood flow and play an obligatory role in Et1 responses. K(+)-channel activity promotes basal flow but exerts little modifying effect on the Et1 response. Cl(-)-channels may be appropriate molecular targets in retinal pathologies characterised by increased Et1 activity and reduced blood flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe associations between reticular pseudodrusen, individual characteristics, and retinal function.

Design: Cohort study.

Participants: We recruited 105 patients (age range, 52–93 years) who had advanced neovascular age-related macular degeneration (AMD) in only 1 eye from 3 clinical centers in Europe.

Methods: Minimum follow-up was 12 months. The eye selected for study was the fellow eye without advanced disease. Clinical measures of vision were distance visual acuity, near visual acuity, and results of the Smith-Kettlewell low-luminance acuity test (SKILL). Fundus imaging included color photography, red-free imaging, blue autofluorescence imaging, fluorescein angiography, indocyanine green angiography, and optical coherence tomography using standardized protocols. These were used to detect progression to neovascular AMD in the study eye during follow-up. All imaging outputs were graded for the presence or absence of reticular pseudodrusen (RPD) using a multimodal approach. Choroidal thickness was measured at the foveal center and at 2 other equidistant locations from the fovea (1500 μm) nasally and temporally. Metrics on retinal thickness and volume were obtained from the manufacturer-supplied automated segmentation readouts.

Main Outcome Measures: Presence of RPD, distance visual acuity, near visual acuity, SKILL score, choroidal thickness, retinal thickness, and retinal volume.

Results: Reticular pseudodrusen was found in 43 participants (41%) on 1 or more imaging method. The SKILL score was significantly worse in those with reticular drusen (mean score ± standard deviation [SD, 38±12) versus those without (mean score ± SD, 33±9) (P = 0.034). Parafoveal retinal thickness, parafoveal retinal volume, and all of the choroidal thickness parameters measured were significantly lower in those with reticular drusen than in those without. The presence of RPD was associated with development of neovascular AMD when corrected for age and sex (odds ratio, 5.5; 95% confidence interval, 1.1–28.8; P = 0.042). All participants in whom geographic atrophy developed during follow-up had visible RPD at baseline.

Conclusions: Significant differences in retinal and choroidal anatomic features, visual function, and risk factor profile exist in unilateral neovascular AMD patients with RPD compared with those without; therefore, such patients should be monitored carefully because of the risk of developing bilateral disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose is to study the diagnostic performance of optical coherence tomography (OCT) and alternative diagnostic tests for neovascular age-related macular degeneration (nAMD). Methods employed are as follows:systematic review and meta-analysis; Index test: OCT including time-domain (TD-OCT) and the most recently developed spectral domain (SD-OCT); comparator tests: visual acuity, clinical evaluation (slit lamp), Amsler chart, colour fundus photographs, infra-red reflectance, red-free images/blue reflectance, fundus autofluorescence imaging (FAF), indocyanine green angiography (ICGA), preferential hyperacuity perimetry (PHP), and microperimetry; reference standard: fundus fluorescein angiography. Databases searched included MEDLINE, MEDLINE In Process, EMBASE, Biosis, SCI, the Cochrane Library, DARE, MEDION, and HTA database. Last literature searches: March 2013. Risk of bias assessed using QUADAS-2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic (HSROC) curves. Twenty-two studies (2 abstracts and 20 articles) enrolling 2124 participants were identified, reporting TD-OCT (12 studies), SD-OCT (1 study), ICGA (8 studies), PHP (3 studies), Amsler grid, colour fundus photography and FAF (1 study each). Most studies were considered to have a high risk of bias in the patient selection (55%, 11/20), and flow and timing (40%, 8/20) domains. In a meta-analysis of TD-OCT studies, sensitivity and specificity (95% CI) were 88% (46–98%) and 78% (64–88%), respectively. There was insufficient information to undertake meta-analysis for other tests. TD-OCT is a sensitive test for detecting nAMD, although specificity was only moderate. Data on SD-OCT are sparse. Diagnosis of nAMD should not rely solely on OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Topic

To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.

Clinical Relevance

Traditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.

Methods

Systematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.

Results

We included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.

Conclusions

There is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.

OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.

DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).

REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.

INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).

COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.

RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.

LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.

CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:To determine the optimal role of OCT in diagnosing and monitoring nAMD (detecting disease activity and the need for further anti-VEGF treatment).
Methods:Systematic review. Major electronic databases and websites were searched. Studies were included if they reported the diagnostic performance of time domain or spectral domain OCT (or selected other tests) against a reference standard of ophthalmologist-interpreted fluorescein angiography in people with newly suspected or previously diagnosed nAMD. Risk of bias was assessed by two independent investigators using QUADAS-2. Summary receiver operating characteristic (SROC) curves were produced for each test given sufficient data.
Results:3700 titles/abstracts were screened, and 120 (3.2%) were selected for full-text assessment. A total of 22 studies were included (17 on diagnosis, 7 monitoring, and 3 both). From 15 studies reporting OCT data, sensitivity and specificity ranged from 59% to 100% and 27% to 100%, respectively.
Conclusions:The reported diagnostic performance of OCT showed large variability. The methodological quality of most studies was sub-optimal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: High density lipoproteins (HDL) protect against cardiovascular disease (CVD). However, increased serum amyloid-A (SAA) related inflammation may negate this property. This study investigated if SAA was related to CVD-burden.

METHODS: Subjects referred to the rapid chest pain clinic (n = 240) had atherosclerotic burden assessed by cardiac computerised tomography angiography. Subjects were classified as: no-CVD (n = 106), non-obstructive-CVD, stenosis<50% (n = 58) or moderate/significant-CVD, stenosis ≥50% (n = 76). HDL was subfractionated into HDL2 and HDL3 by rapid-ultracentrifugation. SAA-concentration was measured by ELISA and lecithin cholesterol acyltransferase (LCAT) activity measured by a fluorimetric assay.

RESULTS: We illustrated that serum-SAA and HDL3-SAA-concentration were higher and HDL3-LCAT-activity lower in the moderate/significant-CVD-group, compared to the no-CVD and non-obstructive-CVD-groups (percent differences: serum-SAA, +33% & +30%: HDL3-SAA, +65% and +39%: HDL3-LCAT, -6% & -3%; p < 0.05 for all comparisons). We also identified a positive correlation between serum-SAA and HDL3-SAA (r = 0.698; p < 0.001) and a negative correlation between HDL3-SAA and HDL3-LCAT-activity (r = -0.295; p = 0.003), while CVD-burden positively correlated with serum-SAA (r = 0.150; p < 0.05) and HDL3-SAA (r = 0.252; p < 0.001) and negatively correlated with HDL3-LCAT-activity (r = -0.182; p = 0.006). Additionally, multivariate regression analysis adjusted for age, gender, CRP and serum-SAA illustrated that HDL3-SAA was significantly associated with modifying CVD-risk of moderate/significant CVD-risk (p < 0.05).

CONCLUSION: This study has demonstrated increased SAA-related inflammation in subjects with moderate/significant CVD-burden, which appeared to impact on the antiatherogenic potential of HDL. We suggest that SAA may be a useful biomarker to illustrate increased CVD-burden, although this requires further investigation.