53 resultados para analytical method validation
Resumo:
A simple, new method permitting the simultaneous determination and confirmation of trace residues of 24 different growth promoters and metabolites using liquid chromatography-mass spectrometry was developed and validated. The compounds were extracted from bovine tissue using acetonitrile; sodium sulphate was also added at this stage to aid with purification. The resulting mixture was then evaporated to approximately 1 ml and subsequently centrifuged at high speed and an aliquot injected onto the LC-MS/MS system. The calculated CC values ranged between 0.11 and 0.46 mu g kg-1; calculated CC were in the range 0.19-0.79 mu g kg-1. Accuracy, measurement of uncertainty, repeatability and linearity were also determined for each analyte. The analytical method was applied to a number of bovine tissue samples imported into Ireland from third countries. Levels of progesterone were found in a number of samples at concentrations ranging between 0.28 and 30.30 mu g kg-1. Levels of alpha- and beta-testosterone were also found in a number of samples at concentrations ranging between 0.22 and 8.63 mu g kg-1 and between 0.16 and 2.08 mu g kg-1 respectively.
Resumo:
The ProSafeBeef project studied the prevalence of residues of anthelmintic drugs used to control parasitic worms and fluke in beef cattle in Ireland. Injured (casualty) cattle may enter the human food chain under certain conditions, verified by an attending veterinarian and the livestock keeper. An analytical survey was conducted to determine if muscle from casualty cattle contained a higher prevalence of anthelmintic drug residues than healthy (full slaughter weight) cattle as a result of possible non-observance of complete drug withdrawal periods. A validated analytical method based on matrix solid-phase dispersive extraction (QuEChERS) and ultra-performance liquid chromatography-tandem mass spectrometry was used to quantify 37 anthelmintic drugs and metabolites in muscle (assay decision limits, CCa, 0.15-10.2 µg kg -1). Of 199 control samples of beef purchased in Irish shops, 7% contained detectable anthelmintic drug residues but all were compliant with European Union Maximum Residue Limits (MRL). Of 305 muscle samples from injured cattle submitted to abattoirs in Northern Ireland, 17% contained detectable residues and 2% were non-compliant (containing either residues at concentrations above the MRL or residues of a compound unlicensed for use in cattle). Closantel and ivermectin were the most common residues, but a wider range of drugs was detected in muscle of casualty cattle than in retail beef. These data suggest that specific targeting of casualty cattle for testing for anthelmintic residues may be warranted in a manner similar to the targeted testing for antimicrobial compounds often applied in European National Residues Surveillance Schemes. © 2012 Copyright Taylor and Francis Group, LLC.
Resumo:
This paper presents experimental and numerical studies into the hydrodynamic loading of a bottom-hinged large buoyant flap held rigidly upright in waves. Possible applications and limitations of physical experiments, a linear potential analytical method, a linear potential numerical method, a weakly non-linear tool and RANS CFD simulations are discussed. Different domains of applicability of these research techniques are highlighted considering the validity of underlying assumptions, complexity of application and feasibility in terms of resources like time and computing power needed to obtain results. Conclusions are drawn regarding the future extension of the numerical methods to the case of a moving flap.
Resumo:
Detection of adulteration of non-processed vegetable oil with lesser value seed oils (classic example is hazelnut in virgin olive oil) has been in the centre of scientific attention for many years and several chemical methods were proposed. The recent EC Regulation 1169/2011, however, introduces necessity for different analytical method in a more complicated matrix. From the end of 2014, food businesses required to declare the composition of the refined oil mixture in the food product label. This creates a gap since there is no analytical method currently available to perform such analysis. In the first phase the work focused on 100% oil blends of various oil species of palm oil (and derivatives), sunflower and rapeseed oil before expanding to foodstuffs. Chromatographic methods remain highly relevant although suffer from various limitations which derive from natural compositional variation. Modern multivariate techniques based on machine learning algorithms, however, when applied in FTIR, Raman spectroscopic data have a strong potential in tackling the problem.
Resumo:
This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.
Resumo:
This chapter presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals, along with the potential use of novel taggants in environmental forensic investigations. The proposed system provides the facilities found in a traditional laboratory-based instrument but in a hand held design, without the need for an associated computer. The electrochemical instrument uses anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise a small disposable plastic strip of screen-printed electrodes rather than the more common glassy carbon disc and gold electrodes. The system is designed for use by a surveyor on site, allowing them to locate hotspots, thus avoiding the expense and time delay of prior laboratory analysis. This is particularly important in environmental forensic analysis when a site may have been released back to the owner and samples could be compromised on return visits. The system can be used in a variety of situations in environmental assessments, the data acquired from which provide a metals fingerprint suitable for input to a database. The proposed novel taggant tracers, based on narrow-band atomic fluorescence, are under development for potential deployment as forensic environmental tracers. The use of discrete fluorescent species in an environmentally stable host has been investigated to replace existing toxic, broadband molecular dye tracers. The narrow band emission signals offer the potential for tracing a large number of signals in the same environment. This will give increased data accuracy and allow multiple source environmental monitoring of environmental parameters.
Resumo:
This paper presents a portable electrochemical instrument capable of detecting and identifying heavy metals in soil, in situ. The instrument has been developed for use in a variety of situations to facilitate contaminated land surveys, avoiding expensive and time-consuming procedures. The system uses differential pulse anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The identification of metals is based on a statistical microprocessor-based method. The instrument is capable of detecting six different toxic metals (lead, cadmium, zinc, nickel, mercury and copper) with good sensitivity
Resumo:
This paper presents an electrochemical instrumentation system capable of real-time in situ detection of heavy metals. A practical approach to introduce acidity compensation against changes in amplitude of the peak currents is also presented. The compensated amplitudes can then be used to predict the concentration level of heavy metals. The system uses differential pulse anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The instrument is capable of detecting lead, cadmium, zinc, nickel and copper with good sensitivity and precision. The system avoids expensive and time-consuming procedures and may be used in a variety of situations to help environmental assessment and control.
Resumo:
The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.
Resumo:
Traditional Chinese Medicines (TCMs) derived from animal horns are one of the most important types of Chinese medicine. In the present study, a fast and sensitive analytical method was established for qualitative and quantitative determination of 14 nucleosides and nucleobases in animal horns using hydrophilic interaction ultra-high performance liquid chromatography coupled with triple-quadruple tandem mass spectrometry (HILIC-UPLC-QQQ-MS/MS) in selective reaction monitoring (SRM) mode. The method was optimized and validated, and showed good linearity, precision, repeatability, and accuracy. The method was successfully used to determine contents of the 14 nucleosides and nucleobases in 25 animal horn samples. Hierarchical clustering analysis (HCA) and principal component analysis (PCA) were performed and the 25 samples were thereby divided into two groups, which agreed with taxonomy. The method may enable quick and effective search of substitutes for precious horns.
Resumo:
Molecular testing is becoming an important part of the diagnosis of any patient with cancer. The challenge to laboratories is to meet this need, using reliable methods and processes to ensure that patients receive a timely and accurate report on which their treatment will be based. The aim of this paper is to provide minimum requirements for the management of molecular pathology laboratories. This general guidance should be augmented by the specific guidance available for different tumour types and tests. Preanalytical considerations are important, and careful consideration of the way in which specimens are obtained and reach the laboratory is necessary. Sample receipt and handling follow standard operating procedures, but some alterations may be necessary if molecular testing is to be performed, for instance to control tissue fixation. DNA and RNA extraction can be standardised and should be checked for quality and quantity of output on a regular basis. The choice of analytical method(s) depends on clinical requirements, desired turnaround time, and expertise available. Internal quality control, regular internal audit of the whole testing process, laboratory accreditation, and continual participation in external quality assessment schemes are prerequisites for delivery of a reliable service. A molecular pathology report should accurately convey the information the clinician needs to treat the patient with sufficient information to allow for correct interpretation of the result. Molecular pathology is developing rapidly, and further detailed evidence-based recommendations are required for many of the topics covered here.
Resumo:
Abstract An HPLC method has been developed and validated for the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples. The method utilises 200 µl of plasma and sample preparation involves protein precipitation followed by Solid Phase Extraction (SPE). Determination of standard curves of peak height ratio (PHR) against concentration was performed by weighted least squares linear regression using a weighting factor of 1/concentration2. The developed method was found to be linear over concentration ranges of 30–1000 ng/ml for spironolactone and 25–1000 ng/ml for 7a-thiomethylspirolactone and canrenone. The lower limit of quantification for spironolactone, 7a-thiomethylspirolactone and canrenone were calculated as 28, 20 and 25 ng/ml, respectively. The method was shown to be applicable to the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples and also plasma from healthy human volunteers.
Resumo:
This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70degreesC. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45 min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95 pmol/8 x 101 RBCs and 2, 5, 2, 3, 20 ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200 mu l of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A research element of the European Union (EU) sixth Framework project BioCop focused on the development of a surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins in shellfish as an alternative to the increasingly ethically unacceptable mouse bioassay. A biosensor assay was developed using both a saxitoxin binding protein and chip surface in tandem with a highly efficient simple extraction procedure. The present report describes the single laboratory validation of this immunological screening method, for this complex group of toxins with differing toxicities, according to the European Decision 2002/657/EC in conjunction with IUPAC and AOAC single laboratory validation guidelines. The different performance characteristics (detection capability CC beta, specificity/selectivity, repeatability, reproducibility, stability, and applicability) were determined in relation to the EU regulatory limit of 800 mu g of saxitoxin equivalents (STX eq) per kg of shellfish meat. The detection capability CC beta was calculated to be 120 mu g/kg. Intra-assay repeatability was found to be between 2.5 and 12.3% and interassay reproducibility was between 6.1 and 15.2% for different shellfish matrices. Natural samples were also evaluated and the resultant data displayed overall agreements of 96 and 92% with that of the existing AOAC approved methods of mouse bioassay (MBA) and high performance liquid chromatography (HPLC), respectively.