38 resultados para Texture géométrique
Resumo:
This study reports the use of texture profile analysis (TPA) to mechanically characterize polymeric, pharmaceutical semisolids containing at least one bioadhesive polymer and to determine interactions between formulation components. The hardness, adhesiveness, force per unit time required for compression (compressibility), and elasticity of polymeric, pharmaceutical semisolids containing polycarbophil (1 or 5% w/w), polyvinylpyrrolidone (3 or 5% w/w), and hydroxyethylcellulose (3, 5, or 10% w/w) in phosphate buffer (pH 6.8) were determined using a texture analyzer in the TPA mode (compression depth 15 mm, compression rate 8 mm s(-1) 15 s delay period). Increasing concentrations of polycarbophil, poly vinylpyrrolidone, and hydroxyethylcellulose significantly increased product hardness, adhesiveness, and compressibility but decreased product elasticity. Statistically, interactions between polymeric formulation components were observed within the experimental design and were probably due to relative differences in the physical states of polyvinylpyrrolidone and polycarbophil in the formulations, i.e., dispersed/dissolved and unswollen/swollen, respectively. Increased product hardness and compressibility were possibly due to the effects of hydroxyethylcellulose, polyvinylpyrrolidone, and polycarbophil on the viscosity of the formulations. Increased adhesiveness was related to the concentration and, more importantly, to the physical state of polycarbophil. Decreased product elasticity was due to the increased semisolid nature of the product. TPA is a rapid, straightforward analytical technique that may be applied to the mechanical characterization of polymeric, pharmaceutical semisolids. It provides a convenient means to rapidly identify physicochemical interactions between formulation components. (C) 1996 John Wiley & Sons, Inc.
Resumo:
PatchCity is a new approach to the procedural generation of city models. The algorithm uses texture synthesis to create a city layout in the visual style of one or more input examples. Data is provided in vector graphic form from either real or synthetic city definitions. The paper describes the PatchCity algorithm, illustrates its use, and identifies its strengths and limitations. The technique provides a greater range of features and styles of city layout than existing generative methods, thereby achieving results that are more realistic. An open source implementation of the algorithm is available.
Resumo:
Biological colonization of stone is a major concern in the preservation and presentation of cultural heritage. Colonization is typically associated with unpleasant soiling, and varying degrees of biodeterioration. A better understanding of why organisms grow where they do, will aid in
developing preventative, and treatment methods for biosoiling of cultural heritage. Sandstone exposure trials were set up at nine different locations across Northern Ireland to investigate the influences of local climate, local environmental,and micro-climatic factors on the early stages (up to 21 months) of biological colonization.
Results showed that, green and yellow soiling occurred on tooled stone surfaces, whereas darkening occurred preferentially on smooth surfaces. It is likely that different populations of organisms occur on these surfaces with green algae occurring on tooled surfaces due to slower drying rates (i.e. prolonged moisture retention), and cyanobacteria and fungi thriving on smooth surfaces due to their ability to withstand moisture fluctuation.
Resumo:
The purpose of this study was to mathematically characterize the effects of defined experimental parameters (probe speed and the ratio of the probe diameter to the diameter of sample container) on the textural/mechanical properties of model gel systems. In addition, this study examined the applicability of dimensional analysis for the rheological interpretation of textural data in terms of shear stress and rate of shear. Aqueous gels (pH 7) were prepared containing 15% w/w poly(methylvinylether-co-maleic anhydride) and poly(vinylpyrrolidone) (PVP) (0, 3, 6, or 9% w/w). Texture profile analysis (TPA) was performed using a Stable Micro Systems texture analyzer (model TA-XT 2; Surrey, UK) in which an analytical probe was twice compressed into each formulation to a defined depth (15 mm) and at defined rates (1, 3, 5, 8, and 10 mm s-1), allowing a delay period (15 s) between the end of the first and beginning of the second compressions. Flow rheograms were performed using a Carri-Med CSL2-100 rheometer (TA Instruments, Surrey, UK) with parallel plate geometry under controlled shearing stresses at 20.0°?±?0.1°C. All formulations exhibited pseudoplastic flow with no thixotropy. Increasing concentrations of PVP significantly increased formulation hardness, compressibility, adhesiveness, and consistency. Increased hardness, compressibility, and consistency were ascribed to enhanced polymeric entanglements, thereby increasing the resistance to deformation. Increasing probe speed increased formulation hardness in a linear manner, because of the effects of probe speed on probe displacement and surface area. The relationship between formulation hardness and probe displacement was linear and was dependent on probe speed. Furthermore, the proportionality constant (gel strength) increased as a function of PVP concentration. The relationship between formulation hardness and diameter ratio was biphasic and was statistically defined by two linear relationships relating to diameter ratios from 0 to 0.4 and from 0.4 to 0.563. The dramatically increased hardness, associated with diameter ratios in excess of 0.4, was accredited to boundary effects, that is, the effect of the container wall on product flow. Using dimensional analysis, the hardness and probe displacement in TPA were mathematically transformed into corresponding rheological parameters, namely shearing stress and rate of shear, thereby allowing the application of the power law (??=?k?n) to textural data. Importantly, the consistencies (k) of the formulations, calculated using transformed textural data, were statistically similar to those obtained using flow rheometry. In conclusion, this study has, firstly, characterized the relationships between textural data and two key instrumental parameters in TPA and, secondly, described a method by which rheological information may be derived using this technique. This will enable a greater application of TPA for the rheological characterization of pharmaceutical gels and, in addition, will enable efficient interpretation of textural data under different experimental parameters.
Resumo:
In shaded scenes surface features can appear either concave or convex, depending upon the viewers judment about the direction of the prevailing illuminant. If other curvature cues are added to the image this ambiguity can be removed. However, it is not clear to what extent, if any, illuminant positin exerts an influence on the perceived magnitude of surface curvature. Subjects were presented with pairs of spherical surface patches in a curavture matching task. The patches were defined by shading and texture cues. The percevied curvature of a standard patch was measured as a function of light source position. We found a clear effect of light source position on apparent curvature. Perceived curvature decreased as light source tilt increased and as light source slant decreased. We also found that the strength of this effect is determined partly by a surface's reflectance function and partly by the relative weight of the texture cue. When a specular component was added to the stimuli, the effect of light source orientation was weakened. The weight of the texture cue was manipulated by disrupting the regular distribution of texture elements. We found an inverse relationship between the strength of the effecct and the weight of the texture cue: lowering the texture cue weight resulted in an enhancement of the illuminant position effect.
Resumo:
Simultaneous contrast effects have been found across a wide range of visual dimensions. We describe a simultaneous contrast effect - three-dimensional curvature contrast - in which the apparent curvature of a surface defined by shading and texture information is influenced by the curvature of a surrounding surface. The effect is strong and easily measurable. We asked whether the effect depends upon the presence of contrast at the level of the internal representation of surface curvature or whether it could be better explained in terms of local changes in the apparent brightness of regions within the test patches induced by luminance transition at the borders. The experimental results suggest that, whicle these luminance-contrast-induced effects do contribute to the observed changes in perceived curvature, there are additional influences. In particular changes in perceived curvature induced by a pattern of curved patches were eliminated or considerably weakened when the inducing pattern was transformed into a photographic negative, a procedure which disrupts the apparent three-dimensional structure of the surface patches without changing their brightness contrast. This suggests a component of the illusion involves comparisons at the level of representation of surface curvature. The observation that three-dimensional curvature contrast presists when the inducing surfaces are spatially separate from the test surface suggests that shape perception involves global, as well as local, operations.
Resumo:
This study described the drug release, rheological (dynamic and flow) and textural/mechanical properties of a series of formulations composed of 15% w/w polymethylvinylether-co-maleic anhydride (PMVE-MA), 0-9% w/w polyvinylpyrrolidone (PVP) and containing 1-5% w/w tetracycline hydrochloride, designed for the treatment of periodontal disease. All formulations exhibited pseudoplastic flow with minimal thixotropy. Increasing the concentration of PVP sequentially increased the zero-rate viscosity (derived from the Cross model) and the hardness and compressibility of the formulations (derived from texture profile analysis). These affects may be accredited to increased polymer entanglement and, in light of the observed synergy between the two polymers with respect to their textural and rheological properties, interaction between PVP and PMVE-MA. Increasing the concentration of PVP increased the storage and loss moduli yet decreased the loss tangent of all formulations, indicative of increased elastic behaviour. Synergy between the two polymers with respect to their viscoelastic properties was observed. Increased adhesiveness, associated with increased concentrations of PVP was ascribed to the increasing bioadhesion and tack of the formulations. The effect of increasing drug concentration on the rheological and textural properties was dependent on PVP concentration. At lower concentrations (0, 3% w/w) no effect was observed whereas, in the presence of 9% w/w PVP, increasing drug concentration increased formulation elasticity, zero rate viscosity, hardness and compressibility. These observations were ascribed to the greater mass of suspended drug in formulations containing the highest concentration of PVP. Drug release from formulations containing 6 and 9% PVP (and 5% w/w drug) was prolonged and swelling/diffusion controlled. Based on the drug release, rheological and textural properties, it is suggested that the formulation containing 15% w/w PMVE-MA, 6% w/w PVP and tetracycline hydrochloride (5% w/w) may be useful for the treatment of periodontal disease.
Resumo:
This study describes the formulation, characterisation and preliminary clinical evaluation of mucoadhesive, semi-solid formulations containing hydroxyethylcellulose (HEC, 1-5%, w/w), polyvinylpyrrolidine (PVP, 2 or 3%, w/w), poly carbophil (PC, 1 or 3%, w/w) and tetracycline (5%, w/w, as the hydrochloride). Each formulation was characterised in terms of drug release, hardness, compressibility, adhesiveness (using a texture analyser in texture profile analysis mode), syringeability (using a texture analyser in compression mode) and adhesion to a mucin disc (measured as a detachment force using the texture analyser in tensile mode). The release exponent for the formulations ranged from 0.78+/-0.02 to 1.27+/-0.07, indicating that drug release was non-diffusion controlled. Increasing the concentrations of each polymeric component significantly increased the time required for 10 and 30% release of the original mass of tetracycline, due to both increased viscosity and, additionally, the unique swelling properties of the formulations. Increasing concentrations of each polymeric component also increased the hardness, compressibility, adhesiveness, syringeability and mucoadhesion of the formulations. The effects on product hardness, compressibility and syringeability may be due to increased product viscosity and, hence, increased resistance to compression. Similarly, the effects of these polymers on adhesiveness/mucoadhesion highlight their mucoadhesive nature and, importantly, the effects of polymer state (particularly PC) on these properties. Thus, in formulations where the neutralisation of PC was maximally suppressed, adhesiveness and mucoadhesion were also maximal. Interestingly, statistical interactions were primarily observed between the effects of HEC and PC on drug release, mechanical and mucoadhesive properties. These were explained by the effects of HEC on the physical state of PC, namely swollen or unswollen. In the preliminary clinical evaluation, a formulation was selected that offered an appropriate balance of the above physical properties and contained 3% HEC, 3% PVP and 1% PC, in addition to tetracycline 5% (as the hydrochloride). The clinical efficacy of this (test) formulation was compared to an identical tetracycline-devoid (control) formulation in nine periodontal pockets (greater than or equal to 5 mm depth). One week following administration of the test formulation, there was a significant improvement in periodontal health as identified by reduced numbers of sub-gingival microbial pathogens. Therefore, it can be concluded that, when used in combination with mechanical plaque removal, the tetracycline-containing semi-solid systems described in this study would augment such therapy by enhancing the removal of pathogens, thus improving periodontal health. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
Co films deposited on obliquely sputtered Pt underlayers of 100 Angstrom or greater have produced coercivities in excess of 800 Oe, and anisotropy fields over 950 Oe. The coercivity and anisotropy field increase with Pt deposition angle and thickness. A Pt capping layer has a detrimental effect on properties but a Cu capping layer does not. Films with an obliquely deposited underlayer exhibit reduced density and increased interface roughness compared to normally deposited films. Normally deposited Pt underlayers display a (111) texture, while those deposited obliquely show an increasingly random texture with Pt thickness and deposition angle. The trilayers fabricated in this study are presented as candidates for use in giant magnetoresistance sensors. (C) 2002 American Institute of Physics.
Resumo:
The potential of Raman spectroscopy for the determination of meat quality attributes has been investigated using data from a set of 52 cooked beef samples, which were rated by trained taste panels. The Raman spectra, shear force and cooking loss were measured and PLS used to correlate the attributes with the Raman data. Good correlations and standard errors of prediction were found when the Raman data were used to predict the panels' rating of acceptability of texture (R-2 = 0.71, Residual Mean Standard Error of Prediction (RMSEP)% of the mean (mu) = 15%), degree of tenderness (R-2 = 0.65, RMSEP% of mu = 18%), degree of juiciness (R-2 = 0.62, RMSEP% of mu = 16%), and overall acceptability (R-2 = 0.67, RMSEP% of mu = 11%). In contrast, the mechanically determined shear force was poorly correlated with tenderness (R-2 = 0.15). Tentative interpretation of the plots of the regression coefficients suggests that the alpha-helix to beta-sheet ratio of the proteins and the hydrophobicity of the myofibrillar environment are important factors contributing to the shear force, tenderness, texture and overall acceptability of the beef. In summary, this work demonstrates that Raman spectroscopy can be used to predict consumer-perceived beef quality. In part, this overall success is due to the fact that the Raman method predicts texture and tenderness, which are the predominant factors in determining overall acceptability in the Western world. Nonetheless, it is clear that Raman spectroscopy has considerable potential as a method for non-destructive and rapid determination of beef quality parameters.