35 resultados para Multiplicação dos Pães
Resumo:
Frequency stability has not necessarily been a major problem for the majority of power systems in the past. However, for economic and environmental reasons, power systems are now operated closer to stability limits to maximise the use of the existing networks. Therefore, introduction of new, more efficient and renewable generation technologies, and their effect on the power system must be fully understood if a reliable and secure electricity supply is to be maintained. Using the Northern Ireland, and interconnected Republic of Ireland electricity networks as a case study, this paper addresses some of the issues regarding integration and modelling of combined cycle gas turbines (CCGT), and wind turbine generator (WTG) technology on a small islanded power system.
Resumo:
Anti-islanding protection is becoming increasingly important due to the rapid installation of distributed generation from renewable resources like wind, tidal and wave, solar PV, bio-fuels, as well as from other resources like diesel. Unintentional islanding presents a potential risk for damaging utility plants and equipment connected from the demand side, as well as to public and personnel in utility plants. This paper investigates automatic islanding detection. This is achieved by deploying a statistical process control approach for fault detection with the real-time data acquired through a wide area measurement system, which is based on Phasor Measurement Unit (PMU) technology. In particular, the principal component analysis (PCA) is used to project the data into principal component subspace and residual space, and two statistics are used to detect the occurrence of fault. Then a fault reconstruction method is used to identify the fault and its development over time. The proposed scheme has been used in a real system and the results have confirmed that the proposed method can correctly identify the fault and islanding site.
Resumo:
A PMU based WAMS is to be placed on a weakly coupled section of distribution grid, with high levels of distributed generation. In anticipation of PMU data a Siemens PSS/E model of the electrical environment has been used to return similar data to that expected from the WAMS. This data is then used to create a metric that reflects optimization, control and protection in the region. System states are iterated through with the most desirable one returning the lowest optimization metric, this state is assessed against the one returned by PSS/E under normal circumstances. This paper investigates the circumstances that trigger SPS in the region, through varying generation between 0 and 110% and compromising the network through line loss under summer minimum and winter maximum conditions. It is found that the optimized state can generally tolerate an additional 2 MW of generation (3% of total) before encroaching the same thresholds and in one instance moves the triggering to 100% of generation output.
Resumo:
This paper is concerned with the voltage and reactive power issues surrounding the connection of Distributed Generation (DG) on the low-voltage (LV) distribution network. The presented system-wide voltage control algorithm consists of three stages. Firstly available reactive power reserves are utilized. Then, if required, DG active power output is curtailed. Finally, curtailment of non-critical site demand is considered. The control methodology is tested on a variant of the 13-bus IEEE Node Radial Distribution Test Feeder. The presented control algorithm demonstrated that the distribution system operator (DSO) can maintain voltage levels within a desired statutory range by dispatching reactive power from DG or network devices. The practical application of the control strategy is discussed.
Resumo:
Demand Side Management (DSM) programmes are designed to shift electrical loads from peak times. Demand Response (DR) algorithms automate this process for controllable loads. DR can be implemented explicitly in terms of Peak to Average Ratio Reduction (PARR), in which case the maximum peak load is minimised over a prediction horizon by manipulating the amount of energy given to controllable loads at different times. A hierarchical predictive PARR algorithm is presented here based on Dantzig-Wolfe decomposition. © 2013 IEEE.
Resumo:
Predictive Demand Response (DR) algorithms allow schedulable loads in power systems to be shifted to off-peak times. However, the size of the optimisation problems associated with predictive DR can grow very large and so efficient implementations of algorithms are desirable. In this paper Laguerre functions are used to significantly reduce the size of the optimisation needed to implement predictive DR, thus significantly increasing the efficiency of the implementation. © 2013 IEEE.
Resumo:
The development of smart grid technologies and appropriate charging strategies are key to accommodating large numbers of Electric Vehicles (EV) charging on the grid. In this paper a general framework is presented for formulating the EV charging optimization problem and three different charging strategies are investigated and compared from the perspective of charging fairness while taking into account power system constraints. Two strategies are based on distributed algorithms, namely, Additive Increase and Multiplicative Decrease (AIMD), and Distributed Price-Feedback (DPF), while the third is an ideal centralized solution used to benchmark performance. The algorithms are evaluated using a simulation of a typical residential low voltage distribution network with 50% EV penetration. © 2013 IEEE.
Resumo:
The development of appropriate Electric Vehicle (EV) charging strategies has been identified as an effective way to accommodate an increasing number of EVs on Low Voltage (LV) distribution networks. Most research studies to date assume that future charging facilities will be capable of regulating charge rates continuously, while very few papers consider the more realistic situation of EV chargers that support only on-off charging functionality. In this work, a distributed charging algorithm applicable to on-off based charging systems is presented. Then, a modified version of the algorithm is proposed to incorporate real power system constraints. Both algorithms are compared with uncontrolled and centralized charging strategies from the perspective of both utilities and customers. © 2013 IEEE.
Resumo:
On formal credit markets, access to formal credit and reasonable credit terms of smallholder farmers
in rural sub-Saharan Africa is limited due to adverse selection. Financial institutions operating in
rural areas often cannot distinguish between borrowers (farmers) that are creditworthy and those that
are not, thus, allocate limited resource to agriculture to reduce credit risk. In the presence of limited business quality signaling by smallholder farmers, financial institutions shall demand for collateral and/or offer unfavorable contract terms. Moreover, agricultural productivity of rural sub-Saharan
Africa, dominated by subsistence or small-scale farmers, is also negatively impacted by the adverse
effect of climate change. A strategy that may make the farming practices of smallholder farmer’s
climate resilient and profitable may also improve smallholder farmer's access to formal credit. This
study investigates to what extent participating in ecosystem and extension services (EES) programs
signals business quality of smallholders, thus granting them credit accessibility. We collected data
on 210 smallholder farmers in 2013, comprising farmers that receive payments for ecosystem
services (PES) and farm management training from the International Small Group Tree Planting
Program (TIST) Kenya to test the aforementioned theory empirically. We use game theory,
particularly a screening and sorting model, to illustrate the prospects for farmers with EES to access
formal credit and to improve their credit terms given that they receive PES and banking services
training. Furthermore, the PES’ long term duration (10 – 30 years) generates stable cash-flow which
may be perceived as collateral substitute. Results suggest that smallholder farmers in the TIST
program were less likely to be credit constraint compared to non-TIST farmers. Distance to market,
education, livestock and farm income are factors that determine access to credit from microfinance
institutions in rural Kenya. Amongst farmers that have obtained loans, those keeping business records
enjoy more favorable formal credit conditions. These farmers were observed to pay ca. 5 percent less
interest rate in microfinance charges. For TIST farmers, this type of farm management practices may
be attributed to the banking services and other training they receive within the program. While the
availability of classical collateral (farmlands) and PES may reduce interest rate, the latter was found
to be statistically insignificant. This research underlines the importance of an effective extension
services in rural areas of developing countries and the need to improve gains from conservation
agriculture and ensuing PES. The benefits associated with EES and PES may encompass agricultural
financing.
Resumo:
Cyber threats in Supervisory Control and Data Acquisition (SCADA) systems have the potential to render physical damage and jeopardize power system operation, safety and stability. SCADA systems were originally designed with little consideration of escalating cyber threats and hence the problem of how to develop robust intrusion detection technologies to tailor the requirements of SCADA is an emerging topic and a big challenge. This paper proposes a stateful Intrusion Detection System (IDS) using a Deep Packet Inspection (DPI) method to improve the cyber-security of SCADA systems using the IEC 60870-5-104 protocol which is tailored for basic telecontrol communications. The proposed stateful protocol analysis approach is presented that is designed specifically for the IEC 60870-5-104 protocol. Finally, the novel intrusion detection approach are implemented and validated.
Resumo:
With the increasing utilization of combined heat and power plants (CHP), electrical, gas, and thermal systems are becoming tightly integrated in the urban energy system (UES). However, the three systems are usually planned and operated separately, ignoring their interactions and coordination. To address this issue, the coupling point of different systems in the UES is described by the energy hub model. With this model, an integrated load curtailment method is proposed for the UES. Then a Monte Carlo simulation based approach is developed to assess the reliability of coordinated energy supply systems. Based on this approach, a reliability-optimal energy hub planning method is proposed to accommodate higher renewable energy penetration. Numerical studies indicate that the proposed approach is able to quantify the UES reliability with different structures. Also, optimal energy hub planning scheme can be determined to ensure the reliability of the UES with high renewable penetration.
Resumo:
This paper discusses a proposed new communications framework for phasor measurement units (PMU) optimized for use on wide area networks. Traditional PMU telecoms have been optimized for use in environments where bandwidth is restricted. The new method takes the reliability of the telecommunications medium into account and provides guaranteed delivery of data whilst optimizing for realtime delivery of the most current data. Other important aspects, such as security, are also considered.