32 resultados para Mg-diclofenac


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new stir bar sorptive extraction (SBSE) technique coupled with HPLC-UV method for quantification of diclofenac in pharmaceutical formulations has been developed and validated as a proof of concept study. Commercially available polydimethylsiloxane stir bars (Twister (TM)) were used for method development and SBSE extraction (pH, phase ratio, stirring speed, temperature, ionic strength and time) and liquid desorption (solvents, desorption method, stirring time etc) procedures were optimised. The method was validated as per ICH guidelines and was successfully applied for the estimation of diclofenac from three liquid formulations viz. Voltarol (R) Optha single dose eye drops, Voltarol (R) Ophtha multidose eye drops and Voltarol (R) ampoules. The developed method was found to be linear (r=0.9999) over 100-2000 ng/ml concentration range with acceptable accuracy and precision (tested over three QC concentrations). The SBSE extraction recovery of the diclofenac was found to be 70% and the LOD and LOQ of the validated method were found to be 16.06 and 48.68 ng/ml, respectively. Furthermore, a forced degradation study of a diclofenac formulation leading to the formation of structurally similar cyclic impurity (indolinone) was carried out. The developed extraction method showed comparable results to that of the reference method, i.e. method was capable of selectively extracting the indolinone and diclofenac from the liquid matrix. Data on inter and intra stir bar accuracy and precision further confirmed robustness of the method, supporting the multiple re-use of the stir bars. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thomson scattering is one of the most powerful diagnostic tools for plasma characterization, and it has been applied to a variety of plasmas. It is a nonintrusive technique, and the interpretation of the signal is relatively simple. However, this method has not been widely applied to low-temperature laser-ablated plasmas. Raman satellites have been observed in the scattering spectrum from a Mg laser-ablated plasma, giving this diagnostic the potential to be also used in density quantification of metastable states in plasmas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Veterinary use of the nonsteroidal anti-inflammatory (NSAID) drug diclofenac in South Asia has resulted in the collapse of populations of three vulture species of the genus Gyps to the most severe category of global extinction risk. Vultures are exposed to diclofenac when scavenging on livestock treated with the drug shortly before death. Diclofenac causes kidney damage, increased serum uric acid concentrations, visceral gout, and death. Concern about this issue led the Indian Government to announce its intention to ban the veterinary use of diclofenac by September 2005. Implementation of a ban is still in progress late in 2005, and to facilitate this we sought potential alternative NSAIDs by obtaining information from captive bird collections worldwide. We found that the NSAID meloxicam had been administered to 35 captive Gyps vultures with no apparent ill effects. We then undertook a phased programme of safety testing of meloxicam on the African white-backed vulture Gyps africanus, which we had previously established to be as susceptible to diclofenac poisoning as the endangered Asian Gyps vultures. We estimated the likely maximum level of exposure (MLE) of wild vultures and dosed birds by gavage (oral administration) with increasing quantities of the drug until the likely MLE was exceeded in a sample of 40 G. africanus. Subsequently, six G. africanus were fed tissues from cattle which had been treated with a higher than standard veterinary course of meloxicam prior to death. In the final phase, ten Asian vultures of two of the endangered species (Gyps bengalensis, Gyps indicus) were dosed with meloxicam by gavage; five of them at more than the likely MLE dosage. All meloxicam-treated birds survived all treatments, and none suffered any obvious clinical effects. Serum uric acid concentrations remained within the normal limits throughout, and were significantly lower than those from birds treated with diclofenac in other studies. We conclude that meloxicam is of low toxicity to Gyps vultures and that its use in place of diclofenac would reduce vulture mortality substantially in the Indian subcontinent. Meloxicam is already available for veterinary use in India.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three Gyps vulture species are on the brink of extinction in South Asia owing to the veterinary non-steroidal anti-inflammatory drug (NSAID) diclofenac. Carcasses of domesticated ungulates are the main food source for Asia's vultures and birds die from kidney failure after consuming diclofenac-contaminated tissues. Here, we report on the safety testing of the NSAID ketoprofen, which was not reported to cause mortality in clinical treatment of scavenging birds and is rapidly eliminated from livestock tissues. Safety testing was undertaken using captive non-releasable Cape griffon vultures (Gyps coprotheres) and wild-caught African white-backed vultures (G. africanus), both previously identified as susceptible to diclofenac and suitable surrogates. Ketoprofen doses ranged from 0.5 to 5 mg kg(-1) vulture body weight, based upon recommended veterinary guidelines and maximum levels of exposure for wild vultures (estimated as 1.54 mg kg(-1)). Doses were administered by oral gavage or through feeding tissues from cattle dosed with ketoprofen at 6 mg kg(-1) cattle body weight, before slaughter. Mortalities occurred at dose levels of 1.5 and 5 mg kg(-1) vulture body weight (within the range recommended for clinical treatment) with the same clinical signs as observed for diclofenac. Surveys of livestock carcasses in India indicate that toxic levels of residual ketoprofen are already present in vulture food supplies. Consequently, we strongly recommend that ketoprofen is not used for veterinary treatment of livestock in Asia and in other regions of the world where vultures access livestock carcasses. The only alternative to diclofenac that should be promoted as safe for vultures is the NSAID meloxicam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gyps vulture populations across the Indian subcontinent are declining rapidly and evidence indicates that veterinary use of the non-steroidal anti-inflammatory drug (NSAID) diclofenac is the major cause. Exposure of vultures to diclofenac is likely to arise from the consumption of livestock carcasses that have been treated shortly before death, however, detailed information regarding the prevalence and residual levels of diclofenac in carcasses available to vultures in India remains unreported. Here, we present data on diclofenac residues in 1848 liver samples taken from carcasses of dead livestock sampled at 67 sites in 12 states within India, between May 2004 and July 2005. Diclofenac residues were detected in carcasses in all states except Orisa, where only one site was sampled. The overall prevalence of detectable diclofenac (>10 microg kg(-1)) across all states was 10.1% and varied significantly among states, with up to 22.3% prevalence determined in Bihar. The geometric mean concentration of diclofenac found in samples in which the drug was detected was 352 microg kg(-1). The prevalence of carcasses containing diclofenac is similar to that previously proposed to be required to have caused the observed Gyps vulture declines in India. On the 11th of May 2006, the Drug Controller General (India) ordered the withdrawal of all licenses granted for the manufacture of diclofenac for veterinary use within India. However, if Gyps vultures are to be protected, potentially substantial existing stocks now need to be quickly and effectively removed from the Indian veterinary market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gyps vultures across India are declining rapidly and the NSAID diclofenac has been shown to be the major cause. Vultures scavenge livestock carcasses that have been treated with diclofenac within the days preceding death. We present data on diclofenac disposition in Indian cow and goat, and field data on the prevalence of diclofenac in carcases in the environment. In the disposition experiment, animals were treated with a single intramuscular injection of diclofenac at 1000 microg kg-1 bw. In cow, diclofenac was detectable in liver, kidney and intestine up to 71 h post-treatment; in plasma, half-life was 12.2 h. In goat, tissue residues were undetectable after 26 h. Prevalence of diclofenac in liver from 36 dead livestock collected in the field was 13.9%. Data suggest that diclofenac residues in Indian cow and goat are short-lived, but diclofenac prevalence in carcasses available to vultures may still be very high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epitaxial (001)-oriented 0.7Pb(Mg0.33Nb0.67)O3-0.3PbTiO3 (PMN-PT) thin films were deposited by pulsed laser deposition on vicinal SrTiO3 (001) substrates using La0.7Sr0.3MnO3 as bottom electrode. Detailed microstructural investigations of these films were carried out using X-ray diffraction (XRD), atomic force microscopy (AFM) and transmission electron microscopy (TEM). Polarization-field hysteresis curves were measured at room temperature. Spontaneous polarization P s , remnant polarization P r and coercive voltage V c were found to be 25 μC/cm2, 15 μC/cm2 and 0.81 V, respectively. Field dependent dielectric constant measurements exhibited butterfly shaped curves, indicating the true ferroelectric nature of these films at room temperature. The dielectric constant and the dielectric loss at 100 kHz were found to be 238 and 0.14, respectively. The local piezoelectric properties of PMN-PT films were investigated by piezoelectric force microscopy and were found to exhibit a local piezoelectric coefficient of 7.8 pm/V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Mg VIII emission lines are observed in a range of astronomical objects such as the Sun, other cool stars and in the coronal line region of Seyfert galaxies. Under coronal conditions Mg VIII emits strongly in the extreme ultraviolet (EUV) and soft X-ray spectral regions which makes it an ideal ion for plasma diagnostics.

Aims. Two theoretical atomic models, consisting of 125 fine structure levels, are developed for the Mg VIII ion. The 125 levels arise from the 2s(2)2p, 2s(2)p2, 2p(3), 2s(2)3s, 2s(2)3p, 2s(2)3d, 2s2p3s, 2s2p3p, 2s2p3d, 2p(2)3s, 2p(2)3p and 2p(2)3d configurations. Electron impact excitation collision strengths and radiative transition probabilities are calculated for both Mg VIII models, compared with existing data, and the best model selected to generate a set of theoretical emission line intensities. The EUV lines, covering 312-790 angstrom, are compared with existing solar spectra (SERTS-89 and SUMER), while the soft X-ray transitions (69-97 angstrom) are examined for potential density diagnostic line ratios and also compared with the limited available solar and stellar observational data.

Methods. The R-matrix codes Breit-Pauli RMATRXI and RMATRXII are utilised, along with the PSTGF code, to calculate the collision strengths for two Mg VIII models. Collision strengths are averaged over a Maxwellian distribution to produce the corresponding effective collision strengths for use in astrophysical applications. Transition probabilities are also calculated using the CIV3 atomic structure code. The best data are then incorporated into the modelling code CLOUDY and line intensities generated for a range of electron temperatures and densities appropriate to solar and stellar coronal plasmas.

Results. The present effective collision strengths are compared with two previous calculations. Good levels of agreement are found with the most recent, but there are large differences with the other for forbidden transitions. The resulting line intensities compare favourably with the observed values from the SERTS-89 and SUMER spectra. Theoretical soft X-ray emission lines are presented and several density diagnostic line ratios examined, which are in reasonable agreement with the limited observational data available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

YAl2p/Mg-14Li-1Al composite was made by a stir-casting technique. The aging behavior of the composite was investigated using hardness test, differential scanning calorimetry, and X-ray diffraction. The results show that the microhardness variations of both the matrix alloy and its composite are related to the precipitation and decomposition of θ-MgLi2Al phase. The strengthening of the composite is from the addition of YAl2 particulates and the precipitation in matrix alloy. The former contribution is stable, but the latter is unstable and depends on the aging behavior. The addition of YAl2 particulates delays occurring of the aging behavior of composite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive and specific competitive ELISA on 96-microwell plates was developed for the analysis of the nonsteroidal anti-inflammatory drug diclofenac. Within the water cycle in Europe, this is one of the most frequently detected pharmaceutically active compounds. The LOD at a signal-tonoise ratio (S/N) of 3, and the IC 50, were found to be 6 ng/L and 60 ng/L respectively in tap water. In a comparative study using ELISA and GC-MS, diclofenac levels in wastewater from 21 sewage treatment plants were determined and a good correlation between these methods was found (ELISA vs. GCMS: r = 0.70, slope = 0,90, intercept = 0.37, n = 24). An average degradation rate of -25% can be calculated. Labscale-experiments on the elimination of diclofenac in continuous pilot sewage plants revealed a removal rate of only 5% over a period of 13 weeks. In a further study, the ELISA was applied to a number of extracts of various animal tissues from a range of species, and again a very good relationship between ELISA and LC-ESI/MS data sets was obtained (r = 0.90, p<0.0001; n = 117). The ELISA has proven to be a simple, rapid, reliable and affordable alternative to otherwise costly and advanced techniques for the detection of diclofenac in matrix diverse water samples and tissue extracts after only relatively simple sample preparation. © 2007 American Chemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theory and experiment are compared for the electron-impact single ionization of Mg and Al+. Nonpertur- bative R matrix with pseudostates RMPS and time-dependent close-coupling TDCC calculations have been carried out that exhibit large reductions from perturbative distorted-wave results of 38% for Mg and 20% for Al+. Experimental single-ionization data available for Mg and Al+ are in reasonable accord with distorted-wave data and lie substantially above the new theoretical results. Rate coefficients, necessary for the collisional- radiative modeling of Mg and Al plasmas were generated from the RMPS ionization cross sections. In the collisional-ionization region near the ionization threshold, the resulting rates were found to be up to two times lower for Mg and three times lower for Al+ than the rates generated from experimental data.