41 resultados para Computer assisted spine surgery (CASS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The self-reported use of natural health products (NHPs) (herbal products and vitamin and mineral supplements) has increased over the past decade in Canada. Because the elderly population might have comorbidities and concurrently administered medications, there is a need to explore the perceptions and behaviors associated with NHPs in this age group. Objective: The goal of this study was to assess the use of NHPs in a cohort of older Canadian residents and the characteristics, perceptions, and behaviors associated with NHP use. Methods: Survey participants aged =60 years were randomly selected from telephone listings in the area of greater Hamilton, Ontario, Canada. Data were collected using a standardized computer-assisted telephone interview system. Self-reported data covering 7 domains were collected: (1) demographics; (2) self-reported 12-month NHP use; (3) reasons for NHP use; (4) self-reported 12-month prescription medication use; (5) expenditures on NHPs; (6) patient-reported adverse events and drug-NHP interactions; and (7) perceptions of physicians' attitudes regarding NHPs. Descriptive statistics were used to compare the characteristics of NHP users with those of nonusers and to assess the characteristics of NHP users across these 7 domains. Multivariate regression analysis was conducted to determine the demographic variables that might be associated with NHP user status. Results: Of 2528 persons identified as age =60 years, 1206 (48%) completed the telephone interview. Six hundred sixteen of these respondents (51%) reported the use of =1 NHP during the previous 12 months. On the initial univariate analysis, younger age and higher income were significantly associated with reporting NHP use (mean age, users vs nonusers, 71.1 vs 72.7 years, respectively; 95% CI, 1.02-1.06; P <0.001; income more than Can $26,000 was 28% and 22% in users and nonusers, respectively; P = 0.028). One hundred seventy of 616 users (28%) used an NHP to treat the same condition for which they were concurrently receiving a prescription medication, and 43 (25%) had not informed their physicians about their NHP use. Patients' characteristics such as sex, education, smoking status, and self-reported health status did not differ significantly between users and nonusers. In individuals who regularly spent money to purchase NHPs (n = 394), the mean cost was $20.38/mo. NHP expenditure was not significantly associated with age, sex, or income. Conclusion: Based on these findings, a substantial proportion of those Ontarians aged =60 years reported NHP use, and there is a need for greater communication with physicians to avoid potential drug-NHP interactions. © 2009 Excerpta Medica Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite several decades of decline, cardiovascular diseases are still the most common causes of death in Western societies. Sedentary living and high fat diets contribute to the prevalence of cardiovascular diseases. This paper analyses the trade-offs between lifestyle choices defined in terms of diet, physical activity, cost, and risk of cardiovascular disease that a representative sample of the population of Northern Ireland aged 40-65 are willing to make. Using computer assisted personal interviews, we survey 493 individuals at their homes using a Discrete Choice Experiment (DCE) questionnaire administered between February and July 2011 in Northern Ireland. Unlike most DCE studies for valuing public health programs, this questionnaire uses a tailored exercise, based on the individuals’ baseline choices. A “fat screener” module in the questionnaire links personal cardiovascular disease risk to each specific choice set in terms of dietary constituents. Individuals are informed about their real status quo risk of a fatal cardiovascular event, based on an initial set of health questions. Thus, actual risks, real diet and exercise choices are the elements that constitute the choice task. Our results show that our respondents are willing to pay for reducing mortality risk and, more importantly, are willing to change physical exercise and dietary behaviours. In particular, we find that to improve their lifestyles, overweight and obese people would be more likely to do more physical activity than to change their diets. Therefore, public policies aimed to target obesity and its related illnesses in Northern Ireland should invest public money in promoting physical activity rather than healthier diets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modern stereologic method of vertical sections was applied to the retina as a means of generating unbiased estimates of three-dimensional structure. The method is illustrated with real data on the volume and surface area of the capillary basement membrane from the central retina of the rat. Novel methods of estimating the volume of retina sampled and of creating accurate vertical sections are described. The advantages of using stereologic methods to generate quantitative information on the three-dimensional structure of the retina are discussed and compared to those of previous quantitative methods that provide data on two-dimensional structure only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper estimates the marginal willingness-to-pay for attributes of a hypothetical HIV vaccine using discrete choice modeling. We use primary data from 326 respondents from Bangkok and Chiang Mai, Thailand, in 2008–2009, selected using purposive, venue-based sampling across two strata. Participants completed a structured questionnaire and full rank discrete choice modeling task administered using computer-assisted personal interviewing. The choice experiment was used to rank eight hypothetical HIV vaccine scenarios, with each scenario comprising seven attributes (including cost) each of which had two levels. The data were analyzed in two alternative specifications: (1) best-worst; and (2) full-rank, using logit likelihood functions estimated with custom routines in Gauss matrix programming language. In the full-rank specification, all vaccine attributes are significant predictors of probability of vaccine choice. The biomedical attributes of the hypothetical HIV vaccine (efficacy, absence of VISP, absence of side effects, and duration of effect) are the most important attributes for HIV vaccine choice. On average respondents are more than twice as likely to accept a vaccine with 99% efficacy, than a vaccine with 50% efficacy. This translates to a willingness to pay US$383 more for a high efficacy vaccine compared with the low efficacy vaccine. Knowledge of the relative importance of determinants of HIV vaccine acceptability is important to ensure the success of future vaccination programs. Future acceptability studies of hypothetical HIV vaccines should use more finely grained biomedical attributes, and could also improve the external validity of results by including more levels of the cost attribute.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To investigate the potential dosimetric and clinical benefits predicted by using four-dimensional computed tomography (4DCT) compared with 3DCT in the planning of radical radiotherapy for non-small cell lung cancer.

MATERIALS AND METHODS:
Twenty patients were planned using free breathing 4DCT then retrospectively delineated on three-dimensional helical scan sets (3DCT). Beam arrangement and total dose (55 Gy in 20 fractions) were matched for 3D and 4D plans. Plans were compared for differences in planning target volume (PTV) geometrics and normal tissue complication probability (NTCP) for organs at risk using dose volume histograms. Tumour control probability and NTCP were modelled using the Lyman-Kutcher-Burman (LKB) model. This was compared with a predictive clinical algorithm (Maastro), which is based on patient characteristics, including: age, performance status, smoking history, lung function, tumour staging and concomitant chemotherapy, to predict survival and toxicity outcomes. Potential therapeutic gains were investigated by applying isotoxic dose escalation to both plans using constraints for mean lung dose (18 Gy), oesophageal maximum (70 Gy) and spinal cord maximum (48 Gy).

RESULTS:
4DCT based plans had lower PTV volumes, a lower dose to organs at risk and lower predicted NTCP rates on LKB modelling (P < 0.006). The clinical algorithm showed no difference for predicted 2-year survival and dyspnoea rates between the groups, but did predict for lower oesophageal toxicity with 4DCT plans (P = 0.001). There was no correlation between LKB modelling and the clinical algorithm for lung toxicity or survival. Dose escalation was possible in 15/20 cases, with a mean increase in dose by a factor of 1.19 (10.45 Gy) using 4DCT compared with 3DCT plans.

CONCLUSIONS:
4DCT can theoretically improve therapeutic ratio and dose escalation based on dosimetric parameters and mathematical modelling. However, when individual characteristics are incorporated, this gain may be less evident in terms of survival and dyspnoea rates. 4DCT allows potential for isotoxic dose escalation, which may lead to improved local control and better overall survival.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.