278 resultados para diagnostic fluorescent PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Noroviruses (NoVs) are the most common cause of epidemic gastroenteritis, responsible for at least 50% of all gastroenteritis outbreaks worldwide and were recently identified as a leading cause of travelers' diarrhea (TD) in US and European travelers to Mexico, Guatemala, and India.

Methods: Serum and diarrheic stool samples were collected from 75 US student travelers to Cuernavaca, Mexico, who developed TD. NoV RNA was detected in acute diarrheic stool samples using reverse transcription-polymerase chain reaction (RT-PCR). Serology assays were performed using GI.1 Norwalk virus (NV) and GII.4 Houston virus (HOV) virus-like particles (VLPs) to measure serum levels of immunoglobulin A (IgA) and IgG by dissociation-enhanced lanthanide fluorescent immunoassay (DELFIA); serum IgM was measured by capture enzyme-linked immunosorbent assay (ELISA), and the 50% antibody-blocking titer (BT50 ) was determined by a carbohydrate-blocking assay.

Results: NoV infection was identified in 12 (16%; 9 GI-NoV and 3 GII-NoV) of 75 travelers by either RT-PCR or fourfold or more rise in antibody titer. Significantly more individuals had detectable preexisting IgA antibodies against HOV (62/75, 83%) than against NV (49/75, 65%) (p = 0.025) VLPs. A significant difference was observed between NV- and HOV-specific preexisting IgA antibody levels (p = 0.0037), IgG (p = 0.003), and BT50 (p = <0.0001). None of the NoV-infected TD travelers had BT50  > 200, a level that has been described previously as a possible correlate of protection.

Conclusion: We found that GI-NoVs are commonly associated with TD cases identified in US adults traveling to Mexico, and seroprevalence rates and geometric mean antibody levels to a GI-NoV were lower than to a GII-NoV strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to rapidly detect circulating small RNAs, in particular microRNAs (miRNAs), would further increase their already established potential as biomarkers in a range of conditions. One rate-limiting factor is the time taken to perform quantitative real time PCR amplification. We therefore evaluated the ability of a novel thermal cycler to perform this step in less than 10 minutes. Quantitative PCR was performed on an xxpress® thermal cycler (BJS Biotechnologies, Perivale, UK), which employs a resistive heating system and forced air cooling to achieve thermal ramp rates of 10 °C/s, and a conventional peltier-controlled LightCycler 480 system (Roche, Basel, Switzerland) ramping at 4.8 °C/s. The threshold cycle (Ct) for detection of 18S rDNA from a standard genomic DNA sample was significantly more variable across the block (F-test, p=2.4x10-25) for the xxpress (20.01±0.47SD) than the LightCycler (19.87±0.04SD). RNA was extracted from human plasma, reverse transcribed and a panel of miRNAs amplified and detected using SYBR green (Kapa Biosystems, Wilmington, Ma, USA). The sensitivity of both systems was broadly comparable and both detected a panel of miRNAs reliably and indicated similar relative abundances. The xxpress thermal cycler facilitates rapid qPCR detection of small RNAs and brings point-of care diagnostics based upon circulating miRNAs a step closer to reality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The European badger (Meles meles) is a natural reservoir for Mycobacterium bovis, the causative agent of Bovine Tuberculosis, and has consequently been implicated in transmission of the disease to cattle. This study describes application of a novel M. bovis-specific immunochromatographic (lateral flow) assay in combination with immunomagnetic separation (IMS-LFD), to test badger faeces samples. In total, 441 faeces samples from badgers of unknown disease status collected from latrines at 110 badger setts throughout Northern Ireland (NI) and 100 faeces samples from badgers of known infection status from Great Britain (GB) were tested. Faeces (approx. 1g) was homogenised in 9 ml phosphate buffered saline, filtered (70 µm), and then 6-8 ml subjected to the IMS-LFD test. Residual clarified faecal homogenates were subjected to automated IMS followed by MGIT™ liquid culture (AIMS-MGIT™ culture) and qPCR (AIMS-qPCR). Evidence for the presence of M. bovis was obtained for 78 (18%), 61 (14%) and 140 (32%) of 441 NI badger faeces samples, and 10 (10%), 41 (41%) and 56 (56%) of 100 GB badger faeces samples, by IMS-LFD, AIMS-MGIT culture and AIMS-qPCR tests, respectively. The IMS-LFD test was less sensitive than AIMS-qPCR for detection of M. bovis and was, therefore, detecting badgers shedding high numbers of M. bovis in their faeces only. However, these ‘super shedders’ may be primarily responsible for the spread of Bovine Tuberculosis so are, therefore, an important target. This non-invasive test could form the basis of a field surveillance tool to indicate infected badger groups which are actively spreading M. bovis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound has long been recognized as a means of effecting change at the cellular and tissue levels [1-3], which may be enhanced in the presence of photosensitive agents [4-6]. During insonation, the presence of bubbles can also play a role, creating strong microstreaming effects in solution and in more dramatic circumstances leading to the formation of energetic microjets [7], plasmas [8], and the production of other highly reactive species [9]. Such sonodynamic activity has generated particular excitement in the medical community as it Moreover the dual role for microbubbles as both an adjunct to therapy and a diagnostic echogenicity enhancer has seen industry take a proactive role in their development. In the present paper we studied the role of ultrasound driven sonoluminescent light on the degradation of a fluorescent test species (rhodamine) in the presence of an archetypal photocatalyst material, TiO 2, with a view to exploring its exploitation potential for downstream medical applications. We found that, whilst the efficiency of this process is seen to be low compared with conventional ultra-violet sources, we advocate the further exploration of the sonoluminescent approach given its potential for non-invasive applications. A strategy for enhancing the effect is also suggested. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human respiratory syncytial virus (HRSV) is the most important viral cause of severe respiratory tract disease in infants. Two subgroups (A and B) have been identified, which cocirculate during, or alternate between, yearly epidemics and cause indistinguishable disease. Existing in vitro and in vivo models of HRSV focus almost exclusively on subgroup A viruses. Here, a recombinant (r) subgroup B virus (rHRSV(B05)) was generated based on a consensus genome sequence obtained directly from an unpassaged clinical specimen from a hospitalized infant. An additional transcription unit containing the gene encoding enhanced green fluorescent protein (EGFP) was introduced between the phosphoprotein and matrix genes (position 5) of the genome to generate rHRSV(B05)EGFP(5). The recombinant viruses replicated efficiently in both HEp-2 cells and in well-differentiated normal human bronchial cells grown at air-liquid interface. Intranasal infection of cotton rats (Sigmodon hispidus) resulted in high numbers of EGFP(+) cells in epithelia of the nasal septum and conchae. When administered in a relatively large inoculum volume, the virus also replicated efficiently in bronchiolar epithelial cells and spread extensively in both the upper and lower respiratory tracts. Virus replication was not observed in ciliated epithelial cells of the trachea. This is the first virulent rHRSV strain with the genetic composition of a currently circulating wild-type virus. In vivo tracking of infected cells by means of EGFP fluorescence in the absence of cytopathic changes increases the sensitivity of virus detection in HRSV pathogenesis studies.

IMPORTANCE

Virology as a discipline has depended on monitoring cytopathic effects following virus culture in vitro. However, wild-type viruses isolated from patients often do not cause significant changes to infected cells, necessitating blind passage. This can lead to genetic and phenotypic changes and the generation of high-titer, laboratory-adapted viruses with diminished virulence in animal models of disease. To address this, we determined the genome sequence of an unpassaged human respiratory syncytial virus from a sample obtained directly from an infected infant, assembled a molecular clone, and recovered a wild-type recombinant virus. Addition of a gene encoding enhanced green fluorescent protein allowed this wild-type virus to be tracked in primary human cells and living animals in the absence of significant cytopathic effects. Imaging of fluorescent cells proved to be a highly valuable tool for monitoring the spread of virus and may help improve assays for evaluating novel intervention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the discovery of the JAK2 V617F mutation in the majority of the myeloproliferative neoplasms (MPN) of polycythemia vera, essential thrombocythemia and primary myelofibrosis ten years ago, further MPN-specific mutational events, notably in JAK2 exon 12, MPL exon 10 and CALR exon 9 have been identified. These discoveries have been rapidly incorporated into evolving molecular diagnostic algorithms. While many of these mutations appear to have prognostic implications, establishing MPN diagnosis is of immediate clinical importance with selection, implementation and the continual evaluation of the appropriate laboratory methodology to achieve this diagnosis similarly vital. The advantages and limitations of these approaches in identifying and quantitating the common MPN-associated mutations is considered herein with particular regard to their clinical utility. The evolution of molecular diagnostic applications and platforms has occurred in parallel with the discovery of MPN-associated mutations and it therefore appears likely that emerging technologies such as next-generation sequencing and digital PCR will in the future, play an increasing role in the molecular diagnosis of MPN. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel selective fluorescent chemosensor based on naphthalimide derivatives (AN-SB) was synthesized and characterized. Once combined with Cu2+, compound AN-SB could give rise to a visible yellow to orange color change and fluorescence quenching, while other metal ions showed subtle disturbance. The complex (AN-SB-Cu2+) formed by Cu2+ and AN-SB displayed high specificity for H2PO4-. Among the various anions, only H2PO4- induced the revival of color and fluorescence of AN-SB, resulting in "off-on" type sensing of H2PO4- anion. The signal transduction occured via reversible formation-separation of complex AN-SB-Cu2+, however, slight changes were observed in the presence of other anions. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A polymeric hydrogel containing a photoinduced electron transfer (PET) based probe for Zn(ii) has been formulated into the wells of a 96-well plate. Upon addition of Zn(ii) ions to selected wells, the fluorescence of the gel was observed to increase in a concentration dependent manner in the 0.25-1.75 mM range. The millimolar binding constant observed for this probe is higher than that reported for other Zn(ii) probes in the literature and offers the possibility to determine the concentration of this ion in environments where the Zn(ii) concentration is high. The combination of the multi-well plate set-up with fluorescence detection offers the possibility of high-throughput screening using low sample volumes in a timely manner. To the best of our knowledge, this is the first reported example of a polymeric hydrogel sensor for zinc with capability for use in fluorescence multi-well plate assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:We conducted the first study to investigate post-diagnostic oral bisphosphonates use and colorectal cancer-specific mortality.

Methods:Colorectal cancer patients were identified from the National Cancer Data Repository (1998–2007) and linked to the UK Clinical Practice Research Datalink, providing prescription records, and Office of National Statistics mortality data. Time-dependent Cox regression models investigated colorectal cancer-specific mortality in post-diagnostic bisphosphonate users.

Results:Overall, in 4791 colorectal cancer patients, there was no evidence of an association between bisphosphonate use and colorectal cancer-specific mortality (adjusted hazard ratio=1.11; 95% confidence interval 0.80, 1.54) or with drug frequency or type.

Conclusions:In this novel population-based cohort study, post-diagnostic bisphosphonate use was not associated with longer rates of colorectal cancer survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic test sensitivity and specificity are probabilistic estimates with far reaching implications for disease control, management and genetic studies. In the absence of 'gold standard' tests, traditional Bayesian latent class models may be used to assess diagnostic test accuracies through the comparison of two or more tests performed on the same groups of individuals. The aim of this study was to extend such models to estimate diagnostic test parameters and true cohort-specific prevalence, using disease surveillance data. The traditional Hui-Walter latent class methodology was extended to allow for features seen in such data, including (i) unrecorded data (i.e. data for a second test available only on a subset of the sampled population) and (ii) cohort-specific sensitivities and specificities. The model was applied with and without the modelling of conditional dependence between tests. The utility of the extended model was demonstrated through application to bovine tuberculosis surveillance data from Northern and the Republic of Ireland. Simulation coupled with re-sampling techniques, demonstrated that the extended model has good predictive power to estimate the diagnostic parameters and true herd-level prevalence from surveillance data. Our methodology can aid in the interpretation of disease surveillance data, and the results can potentially refine disease control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular information gathering and processing – a young field of applied chemistry - is undergoing good growth. The progress is occurring both in terms of conceptual development and in terms of the strengthening of older concepts with new examples. This review critically surveys these two broad avenues. We consider some cases where molecules emulate one of the building blocks of electronic logic gates. We then examine molecular emulation of various Boolean logic gates carrying one, two or three inputs. Some single-input gates are popular information gathering devices. Special systems, such as ‘lab-on-a-molecule’ and molecular keypad locks, also receive attention. A situation deviating from the Boolean blueprint is also discussed. Some pointers are offered for maintaining the upward curve of the field.