242 resultados para 250503 Characterisation of Macromolecules
Resumo:
There is an increasing interest in the biomedical field to create implantable medical devices to provide a temporary mechanical function for use inside the human body. In many of these applications bioresorbable polymer composites using PLLA with β-TCP , are increasingly being used due to their biocompatability, biodegradability and mechanical strength.1,3 These medical devices can be manufactured using conventional plastics processing methods such as injection moulding and extrusion, however there is great need to understand and control the process due to a lack of knowledge on the influence of processing on material properties. With the addition of biocompatible additives there is also a requirement to be able to predict the quality and level of dispersion within the polymer matrix. On-line UV-Vis spectroscopy has been shown to monitor the quality of fillers in polymers. This can eliminate time consuming and costly post-process evaluation of additive dispersion. The aim of this work was to identify process and performance relationships of PLLA/β-TCP composites with respect to melt-extrusion conditions. This is part of a wider study into on-line process monitoring of bioresorbable polymers as used in the medical industry.
These results show that final properties of the PLLA/ β-TCP composite are highly influenced by the particle size and loading. UV-Vis spectroscopy can be used on-line to monitor the final product and this can be utilised as a valuable tool for quality control in an application where consistent performance is of paramount importance.
Resumo:
The paper reports on the mm-wave characterization of a low temperature co-fired ceramic (LTCC) substrate. A substrate integrated resonator (SIW) method is presented for robust extraction of both permittivity and loss tangent of the substrate. The data obtained allow full characterization of the substrate in the 71 GHz – 95 GHz frequency range suitable for accurate modelling of E-and W-band printed circuits.
Resumo:
This paper presents a new methodology for characterising the energy performance of buildings suitable for city-scale, top-down energy modelling. Building properties that have the greatest impact on simulated energy performance were identified via a review of sensitivity analysis studies. The methodology greatly simplifies the description of a building to decrease labour and simulation processing overheads. The methodology will be used in the EU FP7 INDICATE project which aims to create a master-planning tool that uses dynamic simulation to facilitate the design of sustainable, energy efficient smart cities.
Resumo:
The grouts used in sealing or backfilling boreholes should ideally be selected to be compatible with the insitu field instruments installed in the borehole and also be engineered to match closely the geotechnical properties of the parent soils. A stable grout can be made using cement with various proportions of bentonite. The grout stability is very important during both the liquid and set conditions. The liquid grout fluidity should be as viscous as possible to avoid segregation, yet fluid enough to be easily pumpable and fill voids and over-break in the borehole. This paper investigates the effect of bentonite on the fresh and rheological properties of cement-based grouts in order to develop a stable grout to be used in these geotechnical situations. These properties were evaluated by the mini-slump flow, marsh cone flow time, Lombardi plate cohesion meter, static bleeding, yield stress and plastic viscosity values. Additionally, the compressive strength at 3 days, 7 days and 28 days were also investigated. The key parameters investigated were the dosages of bentonite and water-to-binder ratio (W/B). Test results showed that the dosage of bentonite had a significant effect on the fluidity, rheological properties and compressive strength of grout. The increase in the dosage of bentonite led to increasing the values of flow time, plate cohesion meter, yield stress and plastic viscosity, and reducing the mini-slump results, the static bleeding and the compressive strength at 3 days, 7 days and 28 days. Conversely, the increase in W/B led to decreasing the values of flow time, plate cohesion meter, yield stress, and plastic viscosity and the compressive strength, while increasing the mini-slump results and bleeding. Some recommendations for suitable mix proportions for use in soil boreholes are made.
Resumo:
In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.