251 resultados para Uniaxial test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Queen's University Belfast and Wave Barrier Ltd have developed a tidal testing platform to test hydrokinetic turbines at medium scale. Multiple turbines can be pushed through still water conditions, in steady-state pushing tests. Experiments were conducted to evaluate the interactions between two identical, mono-strut, horizontal axis tidal turbines (HATTs) of 1.5 m diameter (D) rotor. Their relative performance when located individually, in-plane and in-line are investigated. The data shows a high consistency in the power curves at different flow speeds, which indicates high repeatability in this Reynolds range. For an individual turbine, there is no performance difference when the rotor is mounted either upstream or downstream of the supporting structure. When placed in-plane, the turbines have no adverse effect on one another. When spaced in-line with 2D separation, there is a 63% reduction in the performance of the downstream turbine. At 6D downstream this performance reduction is still 59%, indicating some wake recovery between 2D and 6D, though the influence from the upstream rotor persists to at least 6D downstream of the first device. In contrast the performance of the downstream turbine when placed at 1.5D offset of the upstream device at 6D downstream is approximately recovered to the individual turbine performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the processing and characterization of Polyamide 6 (PA6) nanocomposites containing graphite nanoplatelets (GNPs) is reported. PA6 nanocomposites were prepared by melt-mixing using an industrial, co-rotating, intermeshing, twin-screw extruder. A bespoke screw configuration was used that was designed in-house to enhance nanoparticle dispersion into a polymer matrix. The effects of nano-filler type (xGnPTM M-5 and xGnPTM C-500), nano-filler content, and extruder screw speed on the bulk properties of the PA6 nanocomposites were investigated. The crystalline structures of PA6 nanocomposites are related to thermal treatment, stress history and the presence of moisture and nanofillers. DSC, Raman and XRD studies show an increase in crystallinity with increasing GNP content and a phase transformation between α-form to γ-form crystals as a result of the heterophase nucleation effect. The effect of uniaxial stretching on PA6 nanocomposites was investigated by drawing specimens heated at temperatures below the melting temperature. DSC and Raman studies on the drawn samples show an increase in yield stress as the GNP content increases due to the strain induced crystallization and γ—β transition during stretching. The rheological response of the nanocomposites resemble that of a ‘pseudo-solid’, rather than a molten liquid, and analysis of the rheological data indicates that a percolation threshold was reached at GNP contents of between 10–15wt%. An increase in tensile modulus of as much as 412% was observed for PA6/C-500 xGnPTM composites, at a filler content of 20wt%. The enhancement of Young’s modulus and yield stress can be attributed to the reinforcing effect of GNPs and their uniform dispersion in the PA6 matrix. The electrical conductivity of the composite also increased with increasing GNP content, with an addition of 15wt% GNP resulting in a 6 order-of-magnitude increase in conductivity. The effects of uniaxial-drawing and the inclusion of multiple nano-filler varieties on the electrical and mechanical properties are currently under investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Despite vaccines and improved medical intensive care, clinicians must continue to be vigilant of possible Meningococcal Disease in children. The objective was to establish if the procalcitonin test was a cost-effective adjunct for prodromal Meningococcal Disease in children presenting at emergency department with fever without source.

METHODS AND FINDINGS: Data to evaluate procalcitonin, C-reactive protein and white cell count tests as indicators of Meningococcal Disease were collected from six independent studies identified through a systematic literature search, applying PRISMA guidelines. The data included 881 children with fever without source in developed countries.The optimal cut-off value for the procalcitonin, C-reactive protein and white cell count tests, each as an indicator of Meningococcal Disease, was determined. Summary Receiver Operator Curve analysis determined the overall diagnostic performance of each test with 95% confidence intervals. A decision analytic model was designed to reflect realistic clinical pathways for a child presenting with fever without source by comparing two diagnostic strategies: standard testing using combined C-reactive protein and white cell count tests compared to standard testing plus procalcitonin test. The costs of each of the four diagnosis groups (true positive, false negative, true negative and false positive) were assessed from a National Health Service payer perspective. The procalcitonin test was more accurate (sensitivity=0.89, 95%CI=0.76-0.96; specificity=0.74, 95%CI=0.4-0.92) for early Meningococcal Disease compared to standard testing alone (sensitivity=0.47, 95%CI=0.32-0.62; specificity=0.8, 95% CI=0.64-0.9). Decision analytic model outcomes indicated that the incremental cost effectiveness ratio for the base case was £-8,137.25 (US $ -13,371.94) per correctly treated patient.

CONCLUSIONS: Procalcitonin plus standard recommended tests, improved the discriminatory ability for fatal Meningococcal Disease and was more cost-effective; it was also a superior biomarker in infants. Further research is recommended for point-of-care procalcitonin testing and Markov modelling to incorporate cost per QALY with a life-time model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic test sensitivity and specificity are probabilistic estimates with far reaching implications for disease control, management and genetic studies. In the absence of 'gold standard' tests, traditional Bayesian latent class models may be used to assess diagnostic test accuracies through the comparison of two or more tests performed on the same groups of individuals. The aim of this study was to extend such models to estimate diagnostic test parameters and true cohort-specific prevalence, using disease surveillance data. The traditional Hui-Walter latent class methodology was extended to allow for features seen in such data, including (i) unrecorded data (i.e. data for a second test available only on a subset of the sampled population) and (ii) cohort-specific sensitivities and specificities. The model was applied with and without the modelling of conditional dependence between tests. The utility of the extended model was demonstrated through application to bovine tuberculosis surveillance data from Northern and the Republic of Ireland. Simulation coupled with re-sampling techniques, demonstrated that the extended model has good predictive power to estimate the diagnostic parameters and true herd-level prevalence from surveillance data. Our methodology can aid in the interpretation of disease surveillance data, and the results can potentially refine disease control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potential standard method for measuring the relative dissolution rate to estimate the resorbability of calcium-phosphate-based ceramics is proposed. Tricalcium phosphate (TCP), magnesium-substituted TCP (MgTCP) and zinc-substituted TCP (ZnTCP) were dissolved in a buffer solution free of calcium and phosphate ions at pH 4.0, 5.5 or 7.3 at nine research centers. Relative values of the initial dissolution rate (relative dissolution rates) were in good agreement among the centers. The relative dissolution rate coincided with the relative volume of resorption pits of ZnTCP in vitro. The relative dissolution rate coincided with the relative resorbed volume in vivo in the case of comparison between microporous MgTCPs with different Mg contents and similar porosity. However, the relative dissolution rate was in poor agreement with the relative resorbed volume in vivo in the case of comparison between microporous TCP and MgTCP due to the superimposition of the Mg-mediated decrease in TCP solubility on the Mg-mediated increase in the amount of resorption. An unambiguous conclusion could not be made as to whether the relative dissolution rate is predictive of the relative resorbed volume in vivo in the case of comparison between TCPs with different porosity. The relative dissolution rate may be useful for predicting the relative amount of resorption for calcium-phosphate-based ceramics having different solubility under the condition that the differences in the materials compared have little impact on the resorption process such as the number and activity of resorbing cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the static & dynamic magnetic characteristics of a high-layer-number NiFe/FeMn multilayer test structure with potential applications in broadband absorber and filter devices. To allow fine control over the absorption linewidths and to understand the mechanisms governing the resonances in a tailored structure similar to that expected to be used in real world applications, the multilayer was intentionally designed to have layer thickness and interface roughness variations. Magnetometry measurements show the sample has complex hysteresis loops with features consistent with single ferromagnetic film reversals. Structural characterisation by transmission electron microscopy allows us to correlate the magnetic properties with structural features. Analysis of resonance frequencies from broadband ferromagnetic resonance measurements as a function of field magnitude and orientation provide values of the local exchange bias, rotatable anisotropy, and uniaxial anisotropy fields for specific layers in the stack and explain the observed mode softening. The linewidths of the multilayer are adjustable around the bias field, approaching twice that seen at larger fields, allowing control over the bandwidth of devices formed from the structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes large scale tests conducted on a novel unglazed solar air collector system. The proposed system, referred to as a back-pass solar collector (BPSC), has on-site installation and aesthetic advantages over conventional unglazed transpired solar collectors (UTSC) as it is fully integrated within a standard insulated wall panel. This paper presents the results obtained from monitoring a BPSC wall panel over one year. Measurements of temperature, wind velocity and solar irradiance were taken at multiple air mass flow rates. It is shown that the length of the collector cavities has a direct impact on the efficiency of the system. It is also shown that beyond a height-to-flow ratio of 0.023m/m<sup>3</sup>/hr/m<sup>2</sup>, no additional heat output is obtained by increasing the collector height for the experimental setup in this study, but these numbers would obviously be different if the experimental setup or test environment (e.g. location and climate) change. An equation for predicting the temperature rise of the BPSC is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tensile strength obtained from existing testing methods such as ASTM D3039, based on flat coupons, usually has a large scatter for fibre reinforced polymer (FRP) composites. This means that the measured strength may not represent the actual strength of the material, leading to under or over design. This paper develops a new interpretation method which requires fewer tests, saving money and time. Moreover the results are more consistent and more closely represent the actual strength which can lead to a safer and more economical design.