216 resultados para Rapid solidification
Resumo:
Quantitative point-of-care (POC) devices are the next generation for serological disease diagnosis. Whilst pathogen serology is typically performed by centralized laboratories using Enzyme-Linked ImmunoSorbent Assay (ELISA), faster on-site diagnosis would infer improved disease management and treatment decisions. Using the model pathogen Bovine Herpes Virus-1 (BHV-1) this study employs an extended-gate field-effect transistor (FET) for direct potentiometric serological diagnosis. BHV-1 is a major viral pathogen of Bovine Respiratory Disease (BRD), the leading cause of economic loss ($2 billion annually in the US only) to the cattle and dairy industry. To demonstrate the sensor capabilities as a diagnostic tool, BHV-1 viral protein gE was expressed and immobilized on the sensor surface to serve as a capture antigen for a BHV-1-specific antibody (anti-gE), produced in cattle in response to viral infection. The gE-coated immunosensor was shown to be highly sensitive and selective to anti-gE present in commercially available anti-BHV-1 antiserum and in real serum samples from cattle with results being in excellent agreement with Surface Plasmon Resonance (SPR) and ELISA. The FET sensor is significantly faster than ELISA (<10 min), a crucial factor for successful disease intervention. This sensor technology is versatile, amenable to multiplexing, easily integrated to POC devices, and has the potential to impact a wide range of human and animal diseases.
Resumo:
The next generation sequencing revolution has enabled rapid discovery of genetic markers, however, development of fully functioning new markers still requires a long and costly process of marker validation. This study reports a rapid and economical approach for the validation and deployment of polymorphic microsatellite markers obtained from a 454 pyrosequencing library of Atlantic cod, Gadus morhua, Linnaeus 1758. Primers were designed from raw reads to amplify specific amplicon size ranges, allowing effective PCR multiplexing. Multiplexing was combined with a three-primer PCR approach using four universal tails to label amplicons with separate fluorochromes. A total of 192 primer pairs were tested, resulting in 73 polymorphic markers. Of these, 55 loci were combined in six multiplex panels each containing between six and eleven markers. Variability of the loci was assessed on G. morhua from the Celtic Sea (n 46) and the Scotian Shelf (n 46), two locations that have shown genetic differentiation in previous studies. Multilocus FST between the two samples was estimated at 0.067 (P 0.001). After three loci potentially under selection were excluded, the global FST was estimated at 0.043 (P 0.001). Our technique combines three- primer and multiplex PCR techniques, allowing simultaneous screening and validation of relatively large numbers of microsatellite loci.
Resumo:
A method is described for the rapid extraction of pectic substances from alcohol insoluble solids (AIS) from material of plant origin, especially fruit. Samples of AIS can be prepared for galacturonic acid assay within 60 min using extraction with 0·5m HCl in a Fibertec-1 system (Tecator) for 30 min. The extraction conditions are carefully standardised and operator error is reduced by the elimination of transfer steps, particularly during filtration. The results obtained for plant-derived alcohol insoluble solids containing from 10% to 33% pectic substances were in close agreement with those obtained by enzymic hydrolysis using a commercially available enzyme preparation (Ultrazyme). The method will have application in the rapid, routine estimation of pectic substances in plant materials. © 1987.
Resumo:
PURPOSE: To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). SETTING: The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. RESULTS: The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). CONCLUSIONS: Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.
Resumo:
Monitoring glacier fluctuations provides insights into changing glacial environments and recent climate change. The availability of satellite imagery offers the opportunity to view these changes for remote and inaccessible regions. Gaining an understanding of the ongoing changes in such regions is vital if a complete picture of glacial fluctuations globally is to be established. Here, satellite imagery (Landsat 7, 8 and ASTER) is used to conduct a multi-annual remote sensing survey of glacier fluctuations on the Kamchatka Peninsula (eastern Russia) over the 2000–2014 period. Glacier margins were digitised manually and reveal that, in 2000, the peninsula was occupied by 673 glaciers, with a total glacier surface area of 775.7 ± 27.9 km2 . By 2014, the number of glaciers had increased to 738 (reflecting the fragmentation of larger glaciers), but their surface area had decreased to 592.9 ± 20.4 km2 . This represents a ∼ 24 % decline in total glacier surface area between 2000 and 2014 and a notable acceleration in the rate of area loss since the late 20th century. Analysis of possible controls indicates that these glacier fluctuations were likely governed by variations in climate (particularly rising summer temperatures), though the response of individual glaciers was modulated by other (non-climatic) factors, principally glacier size, local shading and debris cover.