320 resultados para screening uptake


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An LC/MS/MS method was developed and validated for the simultaneous identification, confirmation, and quantification of 12 glucocorticoids in bovine milk. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. The developed method can detect and confirm the presence of dexamethasone, betamethasone, prednisolone, flumethasone, 6 alpha-methylprednisolone, fluorometholone, triamcinolone acetonide, prednisone, cortisone, hydrocortisone, clobetasol propionate, and clobetasol butyrate in bovine milk. Milk samples are extracted with acetonitrile; sodium chloride is subsequently added to aid partition of the milk and acetonitrile mixture. The acetonitrile extract is then subjected to liquid-liquid purification by the addition of hexane. The purified extract is evaporated to dryness and reconstituted in a water acetonitrile mixture, and determination is carried out by LC/MS/MS. The method permits analysis of up to 30 samples in 1 day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An intelligent ink, previously shown to be capable of rapidly assessing photocatalytic activity, was simply applied via a felt-pen onto a commercially available piece of Activ (TM) self-cleaning glass. The ink, comprising of redox dye resazurin and the sacrificial electron donor glycerol within an aqueous hydroxy ethyl cellulose (HEC) polymer media, was photocatalytically degraded in a two-step process. The key initial stage was the photo-reductive conversion of resazurin to resorufin, whereby a colour change from blue to pink occurred. The latter stage was the subsequent photo-reduction of the resorufin, where a slower change from pink to colourless was seen. Red and green components of red-green-blue colour extracted from flat-bed scanner digital images of resazurin ink coated photocatalytic films at intervals during the photocatalysis reaction were inversely proportional to the changes seen via UV-visible absorption spectroscopy and indicative of reaction kinetics. A 3 x 3 grid of intelligent ink was drawn onto a piece of Activ (TM) and a glass blank. The photocatalysis reaction was monitored solely by flat-bed digital scanning. Red-green-blue values of respective positions on the grid were extracted using a custom-built program entitled RGB Extractor (c). The program was capable of extracting a number of 5 x 5 pixel averages of red-green-blue components simultaneously. Allocation of merely three coordinates allowed for the automatic generation of a grid, with scroll-bars controlling the number of positions to be extracted on the grid formed. No significant change in red and green components for any position on the glass blank was observed; however, the Activ (TM) film displayed a homogenous photo-reduction of the dye, reaching maxima in red and minima in green components in 23 +/- 3 and 14 +/- 2 min, respectively. A compositionally graded N-doped titania film synthesised in house via a combinatorial APCVD reaction was also photocatalytically tested by this method where 247 positions on a 13 x 19 grid were simultaneously analysed. The dramatic variation in photocatalysis observed was rapidly quantified for all positions (2-3 hours) allowing for correlations to be made between thicknesses and N : Ti% compositions attained from Swanepoel and WDX analysis, respectively. N incorporation within this system was found to be detrimental to film activity for the photocatalysis reaction of intelligent ink under 365 nm light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated immunoassay for the detection of nicarbazin residues in poultry eggs and liver was developed. The assay was based on a novel all-in-one dry chemistry concept and time-resolved fluorometry. The analyte specific antibody was immobilized into a single microtiter well and covered with an insulation layer, on top of which the label was dried in a small volume. The extracted sample was added automatically to the dry microtiter well, and the result was available within 18 min. Due to the rapidity and simplicity, the quantitative immunoassay could also be used as a high throughput screening method. The analytical limit of detection for the assay was calculated as 0.1 ng mL(-1) (n = 12) and the functional limit of detection as 3.2 ng g(-1) for egg (n = 6) and 11.3 ng g(-1) for liver (n = 6) samples. The sample recovery varied from 97.3 to 115.6%. Typically, the intra-assay variations were less than 10%, and interassay variations ranged between 8.1 and 13.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted to determine the feasibility of performing

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid imununoassay using an optical biosensor (BIAcore(TM)) for determining the presence of sulphadiazine (SDZ) residues in pig bile was developed. SDZ,cas immobilised onto the surface of a dextran-coated silicon chip and a solution containing SDZ antibody, sample and buffer was injected over the chip surface. The level of antibody binding to the chip was determined after 20 s and the surface of the chip was then regenerated over a 1-min period prior to another sample injection taking place. Standard curves were constructed to allow quantification of SDZ presence in sample. Concentrations ranging from 0 to 10.64 mu g ml(-1) SDZ were detected in bile samples taken from experimentally fed pigs and randomly selected pigs taken from a local slaughterhouse. These results were compared to the concentrations of SDZ detected by high-performance liquid chromatography: in associated tissues. When concentrations in bile exceeded 0.6 mu g ml(-1) SDZ, the corresponding edible tissue was above the maximum residue level (MRL), i.e. 0.1 mu g g(-1) in 13 out of 14 cases. Wizen the bile concentration was less than 0.6 mu ml(-1) the associated tissue concentrations never exceeded rite MRL. This experiment has indicated that biosensor analysis of bile is a highly effective method for detecting violative SDZ residues in meat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ractopamine (RCT) is a phenethanolamine member of the family of beta-adrenergic agonists (beta-agonists), This class of compounds have become notable for their properties of enhancing the growth rates of farm animal species but are not licensed for use in Europe. An ELISA procedure employing a polyclonal antibody raised in a goat was developed to detect RCT residues in bovine urine samples, The assay had a high sensitivity (calibration curve mid-point of 22 pg per well), allowing the analysis of urine samples without the need for sample clean-up. In addition, an LC-MS-MS confirmatory procedure was developed which was able to act as a confirmatory procedure for the ELISA results. Four calves were orally treated with RCT (0.1 mg kg(-1) body mass for 17 d) and urine samples collected were assayed by both analytical procedures. It was observed that RCT residues were excreted mainly in the form of glucuronides and deconjugation could be achieved using two different sources of the enzyme beta-glucuronidase (Helix pomatia and Escherichia coli), High concentrations of RCT residues were found throughout the medication period (44-473 ng ml(-1); LC-MS-MS data) and remained present for several days following removal of the drug from the diet, RCT residues were no longer detectable 2 weeks after withdrawal, Good agreement (r(2) = 0.73) was achieved between the ELISA and LC-MS-MS results, especially when sample deconjugation was applied to the urine samples for both sets of analyses, The results show that an effective screening and confirmatory system was devised to detect RCT residues in urine samples taken during treatment and close to withdrawal, However, alternative matrices may have to be selected to allow the illegal use of the substance to be detected following prolonged withdrawal times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein we disclose the synthesis and SAR of a series of 4-(phenylsulfamoyl)phenylacetamide compounds as mGlu(4) positive allosteric modulators (PAMs) that were identified via a functional HTS. An iterative parallel approach to these compounds culminated in the discovery of VU0364439 (11) which represents the most potent (19.8 nM) mGlu(4) PAM reported to date. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A questionnaire was developed to investigate pharmacists' attitudes to distance learning (DL) as a vehicle for continuing education (CE). It was included in each of a two part DL course on Health Screening. Part One was mailed to all community pharmacists in England (16,400) and returns were received from 1487. The questionnaire in Part Two was returned by 436 pharmacists. Attitude statements were scored using a five-point Likert scale. The mean response to all attitude statements was positive. Participants were significantly more satisfied than non-participants with DL in general and the DL course studied (P less than or equal to 0.05). Over 80 percent of respondents completing the course found DL to be enjoyable and more suitable than other CE methods. More females and less males than expected (based on registration statistics) requested (P less than or equal to 0.001) and completed the course (P less than or equal to 0.001). Pharmacists of all ages participated, although those recently qualified showed greater interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Uptake of the nucleoside uridine by adult Fasciola hepatica during a 2 min period is a linear function of concentration over the range 0.01-2.5 mM.