210 resultados para Dahlia Morgan


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statistics are regularly used to make some form of comparison between trace evidence or deploy the exclusionary principle (Morgan and Bull, 2007) in forensic investigations. Trace evidence are routinely the results of particle size, chemical or modal analyses and as such constitute compositional data. The issue is that compositional data including percentages, parts per million etc. only carry relative information. This may be problematic where a comparison of percentages and other constraint/closed data is deemed a statistically valid and appropriate way to present trace evidence in a court of law. Notwithstanding an awareness of the existence of the constant sum problem since the seminal works of Pearson (1896) and Chayes (1960) and the introduction of the application of log-ratio techniques (Aitchison, 1986; Pawlowsky-Glahn and Egozcue, 2001; Pawlowsky-Glahn and Buccianti, 2011; Tolosana-Delgado and van den Boogaart, 2013) the problem that a constant sum destroys the potential independence of variances and covariances required for correlation regression analysis and empirical multivariate methods (principal component analysis, cluster analysis, discriminant analysis, canonical correlation) is all too often not acknowledged in the statistical treatment of trace evidence. Yet the need for a robust treatment of forensic trace evidence analyses is obvious. This research examines the issues and potential pitfalls for forensic investigators if the constant sum constraint is ignored in the analysis and presentation of forensic trace evidence. Forensic case studies involving particle size and mineral analyses as trace evidence are used to demonstrate the use of a compositional data approach using a centred log-ratio (clr) transformation and multivariate statistical analyses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a study on the gender balance, in speakers and attendees, at the recent major astronomical conference, the American Astronomical Society meeting 223, in Washington, DC. We conducted an informal survey, yielding over 300 responses by volunteers at the meeting. Each response included gender data about a single talk given at the meeting, recording the gender of the speaker and all question-askers. In total, 225 individual AAS talks were sampled. We analyze basic statistical properties of this sample. We find that the gender ratio of the speakers closely matched the gender ratio of the conference attendees. The audience asked an average of 2.8 questions per talk. Talks given by women had a slightly higher number of questions asked (3.2$\pm$0.2) than talks given by men (2.6$\pm$0.1). The most significant result from this study is that while the gender ratio of speakers very closely mirrors that of conference attendees, women are under-represented in the question-asker category. We interpret this to be an age-effect, as senior scientists may be more likely to ask questions, and are more commonly men. A strong dependence on the gender of session chairs is found, whereby women ask disproportionately fewer questions in sessions chaired by men. While our results point to laudable progress in gender-balanced speaker selection, we believe future surveys of this kind would help ensure that collaboration at such meetings is as inclusive as possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inferences in directed acyclic graphs associated with probability intervals and sets of probabilities are NP-hard, even for polytrees. We propose: 1) an improvement on Tessem’s A/R algorithm for inferences on polytrees associated with probability intervals; 2) a new algorithm for approximate inferences based on local search; 3) branch-and-bound algorithms that combine the previous techniques. The first two algorithms produce complementary approximate solutions, while branch-and-bound procedures can generate either exact or approximate solutions. We report improvements on existing techniques for inference with probability sets and intervals, in some cases reducing computational effort by several orders of magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development and optimization of catalysts and catalytic processes requires knowledge of reaction kinetics and mechanisms. In traditional catalyst kinetic characterization, the gas composition is known at the inlet, and the exit flow is measured to determine changes in concentration. As such, the progression of the chemistry within the catalyst is not known. Technological advances in electromagnetic and physical probes have made visualizing the evolution of the chemistry within catalyst samples a reality, as part of a methodology commonly known as spatial resolution. Herein, we discuss and evaluate the development of spatially resolved techniques, including the evolutions and achievements of this growing area of catalytic research. The impact of such techniques is discussed in terms of the invasiveness of physical probes on catalytic systems, as well as how experimentally obtained spatial profiles can be used in conjunction with kinetic modelling. Furthermore, some aims and aspirations for further evolution of spatially resolved techniques are considered.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Disordered sleep and myopia are increasingly prevalent among Chinese children. Similar pathways may be involved in regulation of both sleep cycles and eye growth. We therefore sought to examine the association between disordered sleep and myopia in this group. METHODS: Urban primary school children participating in a clinical trial on myopia and outdoor activity underwent automated cycloplegic refraction with subjective refinement. Parents answered questions about children's sleep duration, sleep disorders (Children's Sleep Habits Questionnaire [CSHQ]), near work and time spent outdoors. RESULTS: Among 1970 children, 1902 (96.5%, mean [standard deviation SD] age 9.80 [0.44] years, 53.1% boys) completed refraction and questionnaires. Myopia < = -0.50 Diopters was present in both eyes of 588 (30.9%) children (1329/3804 = 34.9% of eyes) and 1129 children (59.4%) had abnormal CSHQ scores (> 41). In logistic regression models by eye, odds of myopia < = -0.50D increased with worse CSHQ score (Odds Ratio [OR] 1.01 per point, 95% Confidence Interval [CI] [1.001, 1.02], P = 0.014) and more night-time sleep (OR 1.02, 95% CI [1.01, 1.04, P = 0.002], while male sex (OR 0.82, 95% CI [0.70, 0.95], P = 0.008) and time outdoors (OR = 0.97, 95% CI [0.95, 0.99], P = 0.011) were associated with less myopia. The association between sleep duration and myopia was not significant (p = 0.199) for total (night + midday) sleep. CONCLUSIONS: Myopia and disordered sleep were both common in this cohort, but we did not find consistent evidence for an association between the two. TRIAL REGISTRATION: clinicaltrials.gov NCT00848900.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Importance: This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons.

Objective: To study cohort effects and changes associated with aging in REs among Chinese adults.

Design, Setting, and Participants: A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery.

Methods: Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed.

Main Outcomes and Measures: Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye.

Results: A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from −0.44 (2.21) to −0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at −0.06 mm/y (95% CI, −0.09 to −0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons.

Conclusions and Relevance: This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Setting: Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Design: Comparative evaluation of diagnostic technology. Methods: Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. Results: The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Conclusion: Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The high temperature magnetic and structural properties of an amphiphilic iron(III) spin crossover complex are reported. Thermal cycling reveals a scan rate-dependent 20 K thermal hysteresis in the mT vs. T data close to room temperature. A fast scan rate is essential for the hysteresis but it is robust and reproducible after multiple thermal cycles. Differential scanning calorimetry and cross polarized microscopy are used to show that the magnetic switching aligns with a material state change from solid to ordered liquid phase on warming.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Emerging web applications like cloud computing, Big Data and social networks have created the need for powerful centres hosting hundreds of thousands of servers. Currently, the data centres are based on general purpose processors that provide high flexibility buts lack the energy efficiency of customized accelerators. VINEYARD aims to develop an integrated platform for energy-efficient data centres based on new servers with novel, coarse-grain and fine-grain, programmable hardware accelerators. It will, also, build a high-level programming framework for allowing end-users to seamlessly utilize these accelerators in heterogeneous computing systems by employing typical data-centre programming frameworks (e.g. MapReduce, Storm, Spark, etc.). This programming framework will, further, allow the hardware accelerators to be swapped in and out of the heterogeneous infrastructure so as to offer high flexibility and energy efficiency. VINEYARD will foster the expansion of the soft-IP core industry, currently limited in the embedded systems, to the data-centre market. VINEYARD plans to demonstrate the advantages of its approach in three real use-cases (a) a bio-informatics application for high-accuracy brain modeling, (b) two critical financial applications, and (c) a big-data analysis application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Morphological changes in the retinal vascular network are associated with future risk of many systemic and vascular diseases. However, uncertainty over the presence and nature of some of these associations exists. Analysis of data from large population based studies will help to resolve these uncertainties. The QUARTZ (QUantitative Analysis of Retinal vessel Topology and siZe) retinal image analysis system allows automated processing of large numbers of retinal images. However, an image quality assessment module is needed to achieve full automation. In this paper, we propose such an algorithm, which uses the segmented vessel map to determine the suitability of retinal images for use in the creation of vessel morphometric data suitable for epidemiological studies. This includes an effective 3-dimensional feature set and support vector machine classification. A random subset of 800 retinal images from UK Biobank (a large prospective study of 500,000 middle aged adults; where 68,151 underwent retinal imaging) was used to examine the performance of the image quality algorithm. The algorithm achieved a sensitivity of 95.33% and a specificity of 91.13% for the detection of inadequate images. The strong performance of this image quality algorithm will make rapid automated analysis of vascular morphometry feasible on the entire UK Biobank dataset (and other large retinal datasets), with minimal operator involvement, and at low cost.