212 resultados para Sargo blanco
Resumo:
To independently evaluate and compare the performance of the Ocular Hypertension Treatment Study-European Glaucoma Prevention Study (OHTS-EGPS) prediction equation for estimating the 5-year risk of open-angle glaucoma (OAG) in four cohorts of adults with ocular hypertension.
Resumo:
In clinical trials, the selection of appropriate outcomes is crucial for the assessment of whether one intervention is better than another. Selection of inappropriate outcomes can compromise the utility of a trial. However, the process of selecting the most suitable outcomes to include can be complex. Ideally, glaucoma trials aim to evaluate important outcomes for clinicians and patients. A high variability in the selection of outcomes suggests that there is no consensus on how best to evaluate the effect of glaucoma interventions. Further, it makes evidence synthesis difficult. The purpose of this review is to determine the extent of clinical outcome measures used in published glaucoma Cochrane Reviews and Protocols.
Resumo:
Background: In clinical trials the selection of appropriate outcomes is crucial to the assessment of whether one intervention is better than another. Glaucoma is a chronic eye disease and the leading cause of irreversible blindness in the world. A variety of outcomes has been used and reported in glaucoma RCTs.
Objectives: The purpose of this review is to identify different clinical outcome measures used in glaucoma RCTs between January 2006 and March 2012.
Methods: A systematic review was conducted using standard methodology. We searched for RCTs in glaucoma published in English with no restrictions on the population type or size, or applied interventions. All clinical outcomes were included. Patient-reported, pharmacokinetic and economic outcomes were excluded.
Results: The search strategy identified 4288 potentially relevant abstracts. There were 315 publications retrieved, of which 233 RCTs were included. A total of 967 clinical measures were reported. There were large variations in the definitions used to describe different outcomes and their measures. Intraocular pressure (IOP) was the most commonly reported outcome (used in 201 RCTs, 86%) with a total of 422 measures (44%). Amongst the IOPrelated measures, the most commonly used was mean IOP (n=143, 15% of all measures). Safety outcomes were commonly reported, in 145 RCTs (62%) whereas visual field outcomes were utilized in 38 RCTs (16%).
Conclusions: There is a large variability in clinical outcomes used for glaucoma RCTs and in the way each outcome is reported. This lack of standardisation may impair the ability to evaluate the evidence of glaucoma interventions.
Resumo:
In this paper we propose a novel automated glaucoma detection framework for mass-screening that operates on inexpensive retinal cameras. The proposed methodology is based on the assumption that discriminative features for glaucoma diagnosis can be extracted from the optical nerve head structures,
such as the cup-to-disc ratio or the neuro-retinal rim variation. After automatically segmenting the cup and optical disc, these features are feed into a machine learning classifier. Experiments were performed using two different datasets and from the obtained results the proposed technique provides
better performance than approaches based on appearance. A main advantage of our approach is that it only requires a few training samples to provide high accuracy over several different glaucoma stages.
Resumo:
The purpose is to study the diagnostic performance of optical coherence tomography (OCT) and alternative diagnostic tests for neovascular age-related macular degeneration (nAMD). Methods employed are as follows:systematic review and meta-analysis; Index test: OCT including time-domain (TD-OCT) and the most recently developed spectral domain (SD-OCT); comparator tests: visual acuity, clinical evaluation (slit lamp), Amsler chart, colour fundus photographs, infra-red reflectance, red-free images/blue reflectance, fundus autofluorescence imaging (FAF), indocyanine green angiography (ICGA), preferential hyperacuity perimetry (PHP), and microperimetry; reference standard: fundus fluorescein angiography. Databases searched included MEDLINE, MEDLINE In Process, EMBASE, Biosis, SCI, the Cochrane Library, DARE, MEDION, and HTA database. Last literature searches: March 2013. Risk of bias assessed using QUADAS-2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic (HSROC) curves. Twenty-two studies (2 abstracts and 20 articles) enrolling 2124 participants were identified, reporting TD-OCT (12 studies), SD-OCT (1 study), ICGA (8 studies), PHP (3 studies), Amsler grid, colour fundus photography and FAF (1 study each). Most studies were considered to have a high risk of bias in the patient selection (55%, 11/20), and flow and timing (40%, 8/20) domains. In a meta-analysis of TD-OCT studies, sensitivity and specificity (95% CI) were 88% (46–98%) and 78% (64–88%), respectively. There was insufficient information to undertake meta-analysis for other tests. TD-OCT is a sensitive test for detecting nAMD, although specificity was only moderate. Data on SD-OCT are sparse. Diagnosis of nAMD should not rely solely on OCT.