209 resultados para Measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field testing studies are required for tidal turbine device developers to determine the performance of their turbines in tidal flows. Full-scale testing of the SCHOTTEL tidal turbine has been conducted at Queen’s University Belfast’s tidal site at Strangford Lough, NI. The device was mounted on a floating barge. Testing was conducted over 48 days, for 288 h, during flood tides in daylight hours. Several instruments were deployed, resulting in an expansive data set. The performance results from this data set are presented here. The device, rated to 50 kW at 2.75 m/s was tested in flows up to 2.5 m/s, producing up to 19 kW, when time-averaged. The thrust on the turbine reached 17 kN in the maximum flow. The maximum system efficiency of the turbine in these flows reached 35%. The test campaign was very successful and further tests may be conducted at higher flow speeds in a similar tidal environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper brings together and analyzes recent work based on the interpretation of the electrochemical measurements made on a modified micro-abrasion-corrosion tester used in several research programmes. These programmes investigated the role of abradant size, test solution pH in abrasion-corrosion of biomaterials, the abrasion-corrosion performance of sintered and thermally sprayed tungsten carbide surfaces under downhole drilling environments and the abrasion-corrosion of UNS S32205 duplex stainless steel. Various abrasion tests were conducted under two-body grooving, three-body rolling and mixed grooving-rolling abrasion conditions, with and without abrasives, on cast F75 cobalt-chromium-molybdenum (CoCrMo) alloy in simulated body fluids, 2205 in chloride containing solutions as well as sprayed and sintered tungsten carbide surfaces in simulated downhole fluids. Pre- and post-test inspections based on optical and scanning electron microscopy analysis are used to help interpret the electrochemical response and current noise measurements made in situ during micro-abrasion-corrosion tests. The complex wear and corrosion mechanisms and their dependence on the microstructure and surface composition as a function of the pH, abrasive concentration, size and type are detailed and linked to the electrochemical signals. The electrochemical versus mechanical processes are plotted for different test parameters and this new approach is used to interpret tribo-corrosion test data to give greater insights into different tribo-corrosion systems. Thus new approaches to interpreting in-situ electrochemical responses to surfaces under different abrasive wear rates, different abrasives and liquid environments (pH and NaCl levels) are made. This representation is directly related to the mechano-electrochemical processes on the surface and avoids quantification of numerous synergistic, antagonistic and additive terms associated with repeat experiments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using high-energy (∼0.5 GeV) electron beams generated by laser wakefield acceleration (LWFA), bremsstrahlung radiation was created by interacting these beams with various solid targets. Secondary processes generate high-energy electrons, positrons, and neutrons, which can be measured shot-to-shot using magnetic spectrometers, short half-life activation, and Compton scattering. Presented here are proof-of-principle results from a high-resolution, high-energy gamma-ray spectrometer capable of single-shot operation, and high repetition rate activation diagnostics. We describe the techniques used in these measurements and their potential applications in diagnosing LWFA electron beams and measuring high-energy radiation from laser-plasma interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many kinetic models have appeared in literature in past decades using two main approaches: the traditional global kinetics approach, or the more complex micro-kinetics approach. Whether global or micro-kinetics, kinetic models have been based on experimental data obtained at the end of the monolith. The experimental procedure using end pipe analysis may give an accurate overview of the reaction mechanisms that occur; however, the lack of information from within the catalyst can ultimately lead to inaccuracies in the kinetic model and parameters used.

Using SpaciMS, a spatially resolved experimental technique developed at the Queen's University Belfast, information from within the catalyst can be obtained. This minimally invasive technique provides detailed information of the gas concentration and temperature profile from inside the catalytic monolith. This paper presents a kinetic model and simulations validated against experimental data obtained from three positions inside the catalyst monolith at 2, 14, and 26 mm in, using data from the SpaciMS. Also, simulations of end pipe analysis, using a commercial reactor, for the CO oxidation are presented and analyzed. The simulations presented are for varying concentrations of both CO and O2 (0.5 % and 1 % CO, 0.5 % and 2 % O2) for both the global and micro-kinetic approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the results of radio channel measurements between two hypothetical cellular handsets in an outdoor urban environment are reported. The device-to-device channel measurements were made at 868 MHz and investigated a number of different everyday usage scenarios such as the devices being held at the user's heads, placed in a pocket while one of the users rotated or both moved randomly. It was found that shadowing of the main signal path caused by the human body will be an important factor in future device-to-device communications at this frequency. The recently proposed shadowed κ-μ fading model was used to characterize these channels and shown to provide a good description of the measured data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we compare a number of the classical models used to characterize fading in body area networks (BANs) with the recently proposed shadowed ț–ȝ fading model. In particular, we focus on BAN channels which are considered to be susceptible to shadowing by the human body. The measurements considered in this study were conducted at 2.45 GHz for hypothetical BAN channels operating in both anechoic and highly reverberant environments while the person was moving. Compared to the Rice, Nakagami and lognormal fading models, it was found that the recently proposed shadowed ț௅μ fading model provided an enhanced fit to the measured data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current-voltage-temperature characteristics of PtSi/p-Si Schottky barrier diodes were measured in the temperature range 60-115 K. Deviation of the ideality factor from unity below 80 K may be modelled using the so-called T-0 parameter with T-0 = 18 K. It is also shown that the curvature in the Richardson plots may be remedied by using the flatband rather than the zero-bias saturation current density. Physically, the departure from ideality is interpreted in terms of an inhomogeneous Schottky contact. Here we determine a mean barrier height at T = 0 K, phi(b)(-0) = 223 mV, with an (assumed) Gaussian distribution of standard deviation sigma(phi) = 12.5 mV. These data are correlated with the zero-bias barrier height, phi(j)(0) = 192 mV (at T = 90 K), the photoresponse barrier height, phi(ph) = 205 mV, and the flatband barrier height, phi(fb) = 214 mV. Finally, the temperature coefficient of the flatband barrier was found to be -0.121 mV K-1, which is approximately equal to 1/2(dE(g)(i)/dT), thus suggesting that the Fermi level at the interface is pinned to the middle of the band gap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human occupants within indoor environments are not always stationary and their movement will lead to temporal channel variations that strongly affect the quality of indoor wireless communication systems. This paper describes a statistical channel characterization, based on experimental measurements, of human body effects on line-of-sight indoor narrowband propagation at 5.2 GHz. The analysis shows that, as the number of pedestrians within the measurement location increases, the Ricean K-factor that best fits the empirical data tends to decrease proportionally, ranging from K=7 with 1 pedestrian to K=0 with 4 pedestrians. Level crossing rate results were Rice distributed, while average fade duration results were significantly higher than theoretically computed Rice and Rayleigh, due to the fades caused by pedestrians. A novel CDF that accurately characterizes the 5.2 GHz channel in the considered indoor environment is proposed. For the first time, the received envelope CDF is explicitly described in terms of a quantitative measurement of pedestrian traffic within the indoor environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a scheme for the detection of quantum phase transitions in the one-dimensional (1D) Bose-Hubbard (BH) and 1D Extended Bose-Hubbard (EBH) models, using the nondemolition measurement technique of quantum polarization spectroscopy. We use collective measurements of the effective total angular momentum of a particular spatial mode to characterize the Mott insulator to superfluid phase transition in the BH model and the transition to a density wave state in the EBH model. We extend the application of collective measurements to the ground states at various deformations of a superlattice potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work comprises the photoactivity assessment of transparent sol–gel TiO2 coatings of various thickness using two test systems. The initial rates of both photocatalytic reactions, namely the oxidative bleaching of Acid Orange 7 (AO7) and the reductive bleaching of 2,6-dichlorindophenol (DCIP) increase linearly with increasing titania film thickness as well as with increasing absorbed light flux. The latter work revealed quantum yields (QY) of 0.19% and 92% for the AO7 and DCIP test system, respectively. The low QY for the AO7 oxidation is due to the combination of a slow irreversible reduction of oxygen and also for the oxidation of AO7, thus favouring the high efficiency for electron–hole recombination that is typical for aqueous organic pollutants. In contrast, the very high QY for the photocatalysed reduction of DCIP is due to the presence of a vast excess of glycerol which traps the photogenerated holes efficiently and so allow time for the slower reduction of dye to take place. Furthermore, the oxidation of glycerol results in the generation of highly reducing R-hydroxyalkyl radicals that are able to also reduce DCIP. As a consequence of this ‘current doubling’ effect, the observed QY (92%) is much higher than the apparent theoretical value of 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Well-defined correlates of protective immunity are an essential component of rational vaccine development. Despite years of basic science and three HIV vaccine efficacy trials, correlates of immunological protection from HIV infection remain undefined. In December 2010, a meeting of scientists engaged in basic and translational work toward developing HIV-1 vaccines was convened. The goal of this meeting was to discuss current opportunities and optimal approaches for defining correlates of protection, both for ongoing and future HIV-1 vaccine candidates; specific efforts were made to engage young scientists. We discuss here the highlights from the meeting regarding the progress made and the way forward for a protective HIV-1 vaccine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a portable electrochemical instrument capable of detecting and identifying heavy metals in soil, in situ. The instrument has been developed for use in a variety of situations to facilitate contaminated land surveys, avoiding expensive and time-consuming procedures. The system uses differential pulse anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The identification of metals is based on a statistical microprocessor-based method. The instrument is capable of detecting six different toxic metals (lead, cadmium, zinc, nickel, mercury and copper) with good sensitivity