182 resultados para Corrosion kinetics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The abrasion damage on retrieved CoCrMo based hip joints is reported to be influenced by the entrainment of micron and sub-micron sized debris/hard particles. This paper represents the first attempt to look into the effects of relatively soft abrasives with micron and sub-micron dimensions on the abrasion mechanisms and the abrasion-corrosion performance of the cast CoCrMo in simulated hip joint environments. A modified micro-abrasion tester incorporating a liquid tank and a three-electrode electrochemical cell was used. Al O (300 nm and 1 μm) and sub-micron sized BaSO abrasives were chosen as being comparable in the size and hardness to the wear particles found in vivo. Results show that the specific wear rates of cast CoCrMo are dependent on the abrasive particle size, hardness and volume concentration. Larger particle size, higher hardness and greater abrasive volume fractions gave greater wear rates. The wear-induced corrosion current generally increases with increasing wear rates, and the presence of proteins seems to suppress the wear-induced corrosion current especially when abrasive volume fractions were high. This study shows that the nature of abrasives and the test solutions are both important in determining the wear mechanisms and the abrasion-corrosion response of cast CoCrMo. These findings provide new and important insights into the in vivo wear mechanisms of CoCrMo. © 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The majority of the kinetic models employed in catalytic after-treatment of exhaust emissions use a global kinetic approach owing to the simplicity because one expression can account for all the steps in a reaction. The major drawback of this approach is the limited predictive capabilities of the models. The intrinsic kinetic approach offers much more information about the processes occurring within the catalytic converter; however, it is significantly more complex and time consuming to develop. In the present work, a methodology which allows accessing a model that combines the simplicity of the global kinetic approach and the accuracy of the intrinsic kinetic approach is reported. To assess the performance of this new approach, the oxidation of carbon monoxide in the presence of nitric oxide as well as a driving cycle was investigated. The modelling of carbon monoxide oxidation with oxygen which utilised the intrinsic kinetic approach with the global kinetic approach was used for the carbon monoxide + nitric oxide reaction (and all remaining reactions for the driving cycle). The comparison of the model results for the dual intrinsic + global kinetic approach with the experimental data obtained for both the reactor and the driving cycle indicate that the dual approach is promising with results significantly better than those obtained with only the global kinetics approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we report the antimicrobial planktonic and biofilm kill kinetics of ultrashort cationic lipopeptides previously demonstrated by our group to have a minimum biofilm eradication concentration (MBEC) in the microgram per mL (μg/mL) range against clinically relevant biofilm-forming micro-organisms. We compare the rate of kill for the most potent of these lipopeptides, dodecanoic (lauric) acid-conjugated C12-Orn-Orn-Trp-Trp-NH2 against the tetrapeptide amide H-Orn-Orn-Trp-Trp-NH2 motif and the amphibian peptide Maximin-4 via a modification of the MBEC Assay™ for Physiology & Genetics (P&G). Improved antimicrobial activity is achieved upon N-terminal lipidation of the tetrapeptide amide. Increased antimicrobial potency was demonstrated against both planktonic and biofilm forms of Gram-positive micro-organisms. We hypothesize rapid kill to be achieved by targeting of microbial membranes. Complete kill against established 24-h Gram-positive biofilms occurred within 4 h of exposure to C12-OOWW-NH2 at MBEC values [methicillin-resistant Staphylococcus epidermidis (ATCC 35984): 15.63 μg/mL] close to the values for the planktonic minimum inhibitory concentration (MIC) [methicillin-resistant Staphylococcus epidermidis (ATCC 35984): 1.95 μg/mL]. Such rapid kill, especially against sessile biofilm forms, is indicative of a reduction in the likelihood of resistant strains developing with the potential for quicker resolution of pathogenic infection. Ultrashort antimicrobial lipopeptides have high potential as antimicrobial therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein we report the synthesis, characterisation and hydrolytic release kinetics of a suite of novel, polymerisable ester quinolone conjugates with varying alkenyl chain lengths. Hydrolysis was shown to proceed up to 17-fold faster upon elevation of pH from neutral to pH 9.29, making these conjugates attractive for the development of 'designer' infection-resistant urinary biomaterials exploiting the increase in urine pH reported at the onset of catheter-associated infection to trigger drug release. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chloride-induced corrosion of steel in reinforced concrete structures is one of the main problems affecting their durability and it has been studied for decades, but most of them have focused on concrete without cracking or not subjected to any structural load. In fact, concrete structures are subjected to various types of loads, which lead to cracking when the tensile stress in concrete exceeds its tensile strength. Cracking could increase transport properties of concrete and accelerate the ingress of harmful substances (Cl -, O2, H2 O, CO2). This could initiate and accelerate different types of deterioration processes in concrete, including corrosion of steel reinforcement. The expansive products generated by the deterioration processes themselves can initiate cracking. The success of concrete patch repairs can also influence microcracking at the interface as well as the patch repair itself. Therefore, monitoring the development of microcracking in reinforced concrete members is extremely useful to assess the defects and deterioration in concrete structures. In this paper, concrete beams made using 4 different mixes were subjected to three levels of sustained lateral loading (0%, 50% and 100% of the load that can induce a crack with width of 0.1mmon the tension surface of beams - F 0.1) and weekly cycles of wetting (1 day)/drying (6 days) with chloride solution. The development of microcracking on the surface of concrete was monitored using the Autoclam Permeability System at every two weeks for 60 weeks. The ultrasonic pulse velocity of the concrete was also measured along the beam by using the indirect method during the test period. The results indicated that the Autoclam Permeability System was able to detect the development of microcracks caused by both sustained loading and chloride induced corrosion of steel in concrete. However, this was not the case with the ultrasonic method used in the work (indirect method applied along the beam); it was sensitive to microcracking caused by sustained loading but not due to corrosion. © 2014 Taylor & Francis Group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chloride-induced corrosion of steel is one of the most commonly found problems affecting the durability of reinforced concrete structures in both marine environment and where de-icing salt is used in winter. As the significance of micro-cracks on chloride induced corrosion is not well documented, 24 reinforced concrete beams (4 different mixes - one containing Portland cement and another containing 35% ground granulated blastfurnace slag at 0.45 and 0.65 water-binder ratios) were subjected to three levels of sustained lateral loading (0%, 50% and 100% of the load that can induce 0.1 mm wide cracks on the tension surface of beam - F0.1) in this work. The beams were then subjected to weekly cycles of wetting with 10% NaCl solution for 1 day followed by 6 days of drying at 20 (±1) °C up to an exposure period of 60 weeks. The progress of corrosion of steel was monitored using half-cell potential apparatus and linear polarisation resistance (LPR) test. These results have shown that macro-cracks (at load F0.1) and micro-cracks (at 50% of F0.1) greatly accelerated both the initiation and propagation stages of the corrosion of steel in the concrete beams. Lager crack widths for the F0.1 load cases caused higher corrosion rates initially, but after about 38 weeks of exposure, there was a decrease in the rate of corrosion. However, such trends could not be found in 50% F 0.1 group of beams. The extent of chloride ingress also was influenced by the load level. These findings suggest that the effect of micro-cracking at lower loads are very important for deciding the service life of reinforced concrete structures in chloride exposure environments. © 2014 4th International Conference on the Durability of Concrete Structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alkali activated slag (AAS) is an alternative cementitious material. Sodium silicate solution is usually used to activate ground granulated blast furnace slag to produce AAS. As a consequence, the pore solution chemistry of AAS differs from that of Portland cement (PC). Although AAS offers many advantages over PC, such as higher strength, superior resistance to acid and sulphate environments and lower embodied carbon due to 100% PC replacement, there is a need to assess its performance against chloride induced corrosion duo to its different pore solution chemistry. For PC systems, resistivity measurement, as a type of nondestructive test, is usually used to evaluate its chloride diffusivity and the corrosion rate of the embedded steel. However, due to the different pore solution chemistry present in the different AAS systems, the application of this test in AAS concretes would be questionable as the resistivity of concrete is highly dependent on its conductivity of the pore solution. Therefore, a study was carried out using twelve AAS concretes mixes, the results of which are reported in this paper. The AAS mixes were designed with alkali concentration of 4%, 6% and 8% (Na2O% of the mass of slag) and modulus (Ms) of sodium silicate solution of 0.75, 1.00, 1.50 and 2.00. A PC concrete with the same binder content as the AAS concretes was also studied as a reference. The chloride diffusion coefficient was determined using a non-steady state chloride diffusion test (NT BUILD 443). The resistivity of the concretes before the diffusion test was also measured. Macrocell corrosion current (corrosion rate) for steel rods embedded in the concretes was measured whilst subjecting the concretes to a cyclic chloride ponding regime (1 day ponded with salt solution and 6 days drying). The results showed that the AAS concretes had lower chloride diffusivity with associated higher resistivity than the PC concrete. The measured corrosion rate was also lower for the AAS concretes. However, unlike the PC, in which a higher resistivity yields a lower diffusivity and corrosion rate, there was no relationship apparent between the resistivity and either the diffusivity or the corrosion rate of steel for the AAS concretes. This is assigned to the variation of the pore solution composition of the AAS concretes. This also means that resistivity measurements cannot be depended on for assessing the chloride induced corrosion resistance of AAS concretes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesoporous materials were used as adsorbents for dye removal in different media: non-ionic, buffered and saline. The mesoporous materials used were commercial (silica gel) as well as as-synthesised materials (SBA-15 and a novel mesoporous carbon). Dye adsorption onto all the materials was very fast and the equilibrium was reached before 1h. The pH has a significant influence on the adsorption capacity for the siliceous materials since the electrostatic interactions are the driving forces. However, the influence of the pH on the adsorption capacity of the carbonaceous material was lower, since the van der Waals interactions are the driving forces. The ionic strength has a great impact on the siliceous materials adsorption capacity, being their adsorption capacity in a buffered medium six times higher than the corresponding to a non-ionic medium. Nevertheless, ionic strength does not influence on the dye adsorption on the mesoporous carbon. Overall, the as-synthesised carbon material presents a clear potential to treat dye effluents, showing high adsorption capacity (qe≈200mg/g) in all the pH range studied (from 3 to 11); even at low concentrations (Ce≈10mg/L) and at short contact times (te<30min).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Systemic exposure to parabens in the neonatal population, in particular propyl-parabens (PPB), remains a concern. Blood concentrations and kinetics of methyl-parabens (MPB) and PPB were therefore determined in neonates receiving medicines containing these excipients.

Methods: A multi-centre, non-interventional, observational study of excipient-kinetics in neonates. ‘Dried Blood Spot’ samples were collected opportunistically at the same time as routine samples and the observations modelled using a non-linear mixed effects approach.

Results: A total of 841 blood MPB and PPB concentration data were available for evaluation from 181 pre- and term-neonates. Quantifiable blood concentrations of MPB and PPB were observed in 99% and 49% of patients, and 55% and 25% of all concentrations were above limit of detection (10 ng/ml), respectively. Only MPB data was amenable to modelling. Oral bioavailability was influenced by type of formulation and disposition was best described by a two compartment model with clearance (CL) influenced by post natal age (PNA); CLPNA<21 days 0.57 versus CLPNA>21days 0.88 L/h.

Conclusions: Daily repeated administration of parabens containing medicines can result in prolonged systemic exposure to the parent compound in neonates. Animal toxicology studies of PPB that specifically address the neonatal period are required before a permitted daily exposure for this age group can be established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanisms and kinetics studies of the formation of levoglucosan and formaldehyde from anhydroglucose radical have been carried out theoretically in this paper. The geometries and frequencies of all the stationary points are calculated at the B3LYP/6-31+G(D,P) level based on quantum mechanics, Six elementary reactions are found, and three global reactions are involved. The variational transition-state rate constants for the elementary reactions are calculated within 450-1500 K. The global rate constants for every pathway are evaluated from the sum of the individual elementary reaction rate constants. The first-order Arrhenius expressions for these six elementary reactions and the three pathways are suggested. By comparing with the experimental data, computational methods without tunneling correction give good description for Path1 (the formation of levoglucosan); while methods with tunneling correction (zero-curvature tunneling and small-curvature tunneling correction) give good results for Path2 (the first possibility for the formation of formaldehyde), all the test methods give similar results for Path3 (the second possibility for the formation of formaldehyde), all the modeling results for Path3 are in good agreement with the experimental data, verifying that it is the most possible way for the formation of formaldehyde during cellulose pyrolysis. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Chemical Equation Presented) The mechanisms and kinetics studies of the levoglucosan (LG) primary decomposition during cellulose pyrolysis have been carried out theoretically in this paper. Three decomposition mechanisms (C-O bond scission, C-C bond scission, and LG dehydration) including nine pathways and 16 elementary reactions were studied at the B3LYP/6-31 + G(D,P) level based on quantum mechanics. The variational transi-tion- state rate constants for every elementary reaction and every pathway were calculated within 298-1550 K. The first-order Arrhenius expressions for these 16 elementary reactions and nine pathways were suggested. It was concluded that computational method using transition state theory (TST) without tunneling correction gives good description for LG decomposition by comparing with the experimental result. With the temperature range of 667-1327 K, one dehydration pathway, with one water molecule composed of a hydrogen atom from C3 and a hydroxyl group from C2, is a preferred LG decomposition pathway by fitting well with the experimental results. The calculated Arrhenius plot of C-O bond scission mechanism is better agreed with the experimental Arrhenius plot than that of C-C bond scission. This C-O bond scission mechanism starts with breaking of C1-O5 and C6-O1 bonds with formation of CO molecule (C1-O1) simultaneously. C-C bond scission mechanism is the highest energetic barrier pathway for LG decomposition. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyclic voltammograms of quinones were recorded in acetonitrile in the presence of various substrates: carbonyl compounds, halobenzenes, Methyl Viologen and Neutral Red. When illuminated with light of λ >410 nm, catalytic waves were observed. From the ratio of the catalysed to uncatalysed peak current, electron transfer rate constants were calculated using the working curves of Saveant and coworkers. The values of these rate constants were compared with the values obtained by Shukla and Rusling for different systems using a similar method and with quenching rate constants calculated using Rehm-Weller-Marcus theory.