140 resultados para initial algebraic concepts
Resumo:
Seafloor massive sulfides (SMS) contain commercially viable quantities of high grade ores, making them attractive prospect sites for marine mining. SMS deposits may also contain hydrothermal vent ecosystems populated by high conservation value vent-endemic species. Responsible environmental management of these resources is best achieved by the adoption of a precautionary approach. Part of this precautionary approach involves the Environmental Impact Assessment (EIA) of exploration and exploitative activities at SMS deposits. The VentBase 2012 workshop provided a forum for stakeholders and scientists to discuss issues surrounding SMS exploration and exploitation. This forum recognised the requirement for a primer which would relate concepts underpinning EIA at SMS deposits. The purpose of this primer is to inform policy makers about EIA at SMS deposits in order to aid management decisions. The primer offers a basic introduction to SMS deposits and their associated ecology, and the basic requirements for EIA at SMS deposits; including initial data and information scoping, environmental survey, and ecological risk assessment. © 2013 Elsevier Ltd.
Resumo:
PURPOSE: To compare initial glaucoma therapy with medications and trabeculectomy in southern India. METHODS: Patients aged ≥ 30 years newly diagnosed with glaucoma were randomized to trabeculectomy with 5-fluorouracil or medical therapy. Subjects with best-corrected vision <6/18 due to cataract underwent phacoemulsification (phaco/intraocular lens, IOL). Intraocular pressure (IOP), vision and visual function were assessed at 12 months. RESULTS: Patients assigned to medications and surgery received the expected therapy in 86% (172/199) and 64% (126/199) of cases, respectively. Forty patients (20%) assigned to surgery refused any treatment and 33 (17%) received medications. Among 199 patients randomized to medications, 52 (26.1%) underwent phaco/IOL, as did 89/199 (43.7%) of patients randomized to trabeculectomy. Baseline parameters of the two groups did not differ, nor did 1-year follow-up rates (medication 65%, trabeculectomy 58%, P = 0.15). Final IOP was lower with randomization to trabeculectomy (16.3 ± 5.1 mmHg) than medication (18.8 ± 6.7 mmHg, P < 0.0001). In regression models, randomization to trabeculectomy (P < 0.0001) was associated with lower IOP, and simultaneous trabeculectomy and cataract surgery was associated with higher IOP (P = 0.008) than trabeculectomy alone. Subjects receiving Phaco/IOL had significantly better final acuity (P < 0.0001) and visual function (P = 0.035), despite concurrent glaucoma treatment. Final visual acuity was worse in those receiving trabeculectomy in addition to cataract surgery, but this was of borderline significance (P = 0.06). CONCLUSIONS: Trabeculectomy lowered IOP significantly more than medical treatment, but with slightly greater loss of visual acuity. Combined phaco/IOL and trabeculectomy improved visual acuity with substantial IOP lowering.
Resumo:
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.