143 resultados para cutting room


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics (MD) simulation was carried out to acquire an in-depth understanding of the flow behaviour of single crystal silicon during nanometric cutting on three principal crystallographic planes and at different cutting temperatures. The key findings were that (i) the substrate material underneath the cutting tool was observed for the first time to experience a rotational flow akin to fluids at all the tested temperatures up to 1200 K. (ii) The degree of flow in terms of vorticity was found higher on the (1 1 1) crystal plane signifying better machinability on this orientation in accord with the current pool of knowledge (iii) an increase in the machining temperature reduces the springback effect and thereby the elastic recovery and (iv) the cutting orientation and the cutting temperature showed significant dependence on the location of the stagnation region in the cutting zone of the substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of liquid rare-earth chlorometallate complexes with alkyl-phosphonium cations, [P666 14]+, has been synthesised and characterised. EXAFS confirmed the predominant liquid-state speciation of the [LnCl6]3- of the series with Ln = Nd, Eu, Dy. The crystal structure of the shorter-alkyl-chain cation analogue [P4444]+ has been determined and exhibits a very large unit cell. The luminescence properties, with visible light emissions of the liquid Tb, Eu, Pr and Sm and the NIR emissions for the Nd and Er compounds were determined. The effective magnetic moments were measured and fitted for the Nd, Tb, Ho, Dy, Gd and Er samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. METHODS: Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. RESULTS: A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P < 0.001) and smaller than that in standard room illumination (P = 0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P < 0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P = 0.157). CONCLUSIONS: Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high temperature magnetic and structural properties of an amphiphilic iron(III) spin crossover complex are reported. Thermal cycling reveals a scan rate-dependent 20 K thermal hysteresis in the mT vs. T data close to room temperature. A fast scan rate is essential for the hysteresis but it is robust and reproducible after multiple thermal cycles. Differential scanning calorimetry and cross polarized microscopy are used to show that the magnetic switching aligns with a material state change from solid to ordered liquid phase on warming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the hydrogeological processes which caused unexpected instability and quick conditions during the excavation of a 25m deep cutting through a drumlin in County Down, Northern Ireland. A conceptual hydrogeological model of the cutting, based on pore pressures monitored during and after the excavation demonstrates how quick conditions at the toe of the cutting caused liquefaction of the till. Stability of the cutting was re-established by draining the highly permeable, weathered Greywacke which underlies the drumlin, through the use of a deep toe drain. In spite of this drainage, the cutting was only marginally stable due to the presence of a low permeability zone in the till above the bedrock which limits the reduction of elevated pore pressures within the upper to mid-depths of the drumlin. The factor of safety has been further improved by the addition of vertical relief drains at the crest and berm of the cutting to relieve the pore-pressures within the upper till by intercepting the weathered bedrock. The paper also highlights the importance of carrying out an adequate site investigation compliant with Eurocode 7 and additional monitoring in excavations in stiff, low permeability till.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound absorption spectra of four 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide were determined as a function of the alkyl chain length on the cation from 1-propyl- to 1-hexyl- from 293.15 to 323.15 K at ambient pressure. Herein, the ultrasound absorption measurements were carried out using a standard pulse technique within a frequency range from 10 to 300 MHz. Additionally the speed of sound, density and viscosity have been measured. The presence of strong dissipative processes during the ultrasound wave propagation was found experimentally, i.e. relaxation processes in the megahertz range were observed for all compounds over the whole temperature range. The relaxation spectra (both relaxation amplitude and relaxation frequency) were shown to be dependent on the alkyl side chain length of the 1-alkyl-3-methylimidazolium ring. In most cases, a single Debye model described the absorption spectra very well. However, a comparison of the determined spectra with the spectra of a few other imidazolium-based ionic liquids reported in the literature (in part recalculated in this work) shows that the complexity of the spectra increases rapidly with the elongation of the alkyl chain length on the cation. This complexity indicates that both the volume viscosity and the shear viscosity are involved in relaxation processes even in relatively low frequency ranges. As a consequence, the sound velocity dispersion is present at relatively low megahertz frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the environmental conditions inside a highly-glazed cross-ventilated meeting room. A 3D computational fluid dynamics (CFD) model of an indoor environment is developed with the support of the field measurements performed in a normally operating room. The work presented here follows the steps of the formal calibration methodology for the development of CFD models of naturally ventilated environments. This paper utilises the calibration methodology in order to predict environmental conditions within the highly-glazed cross-ventilated room occupied by people. The CFD model is verified and validated with field measurements performed in an operating building. Moreover, parametric analysis determines the most influential boundary conditions on indoor air temperatures and air speeds