25 resultados para low threshold pumping
Resumo:
Objective: The aim was to investigate whether there was an association between periodontitis or tooth loss in a homogeneous group of 60-70-year-old Western European men and either a sustained high or low level of C-reactive protein (CRP).
Material and Methods: Men enrolled in a cohort study of cardiovascular disease in Northern Ireland were screened in 1990-1994 and rescreened in 2001-2004, when a periodontal examination was completed. High-sensitivity CRP was measured from fasting blood samples. There were 806 men with six or more teeth who had either a high level (>3 mg/l) or a lower level of CRP at both time points. Multivariate analysis was carried out using logistic regression with adjustment for possible confounders. Models were constructed with the CRP level as the outcome variable and various measures of periodontal status (low and high threshold periodontitis) or tooth loss as predictor variables. Confounders included in the analysis were known cardiovascular risk factors of age, smoking, diabetes, BMI and socioeconomic status.
Results: There were 67 men who had a high value of CRP (>3 mg/l) and 739 men who had a CRP value =3 mg/l at both time points. The unadjusted odds ratio (OR) for advanced periodontitis to be associated with high CRP was 3.62, p=0.0003. The association was somewhat attenuated but remained significant (OR=2.49, p=0.02) after adjustment for confounders. A high level of tooth loss was also associated with high CRP with an adjusted OR of 2.17, p=0.008. Low threshold periodontitis was not associated with the level of CRP.
Conclusion: There was an association between advanced periodontitis and elevated CRP levels as measured at two time points at a 10-year interval in the 60-70-year-old European males investigated. This association was adjusted for various cardiovascular risk factors. There was also an association between high levels of tooth loss and high CRP in the men studied.
Resumo:
Objective: The aim was to investigate the association between periodontal health and the serum levels of various antioxidants including carotenoids, retinol and vitamin E in a homogenous group of Western European men.
Materials and Methods: A representative sample of 1258 men aged 60-70 years, drawn from the population of Northern Ireland, was examined between 2001 and 2003. Each participant had six or more teeth, completed a questionnaire and underwent a clinical periodontal examination. Serum lipid-soluble antioxidant levels were measured by high-performance liquid chromatography with diode array detection. Multivariable analysis was carried out using logistic regression with adjustment for possible confounders. Models were constructed using two measures of periodontal status (low- and high-threshold periodontitis) as dependent variables and the fifths of each antioxidant as a predictor variable.
Results: The levels of a- and ß-carotene, ß-cryptoxanthin and zeaxanthin were highly significantly lower in the men with low-threshold periodontitis (p<0.001). These carotenoids were also significantly lower in high-threshold periodontitis. There were no significant differences in the levels of lutein, lycopene, a- and ?-tocopherol or retinol in relation to periodontitis. In fully adjusted models, there was an inverse relationship between a number of carotenoids (a- and ß-carotene and ß-cryptoxanthin) and low-threshold periodontitis. ß-Carotene and ß-cryptoxanthin were the only antioxidants that were associated with an increased risk of high-threshold severe periodontitis. The adjusted odds ratio for high-threshold periodontitis in the lowest fifth relative to the highest fifth of ß-cryptoxanthin was 4.02 (p=0.003).
Conclusion: It is concluded that low serum levels of a number of carotenoids, in particular beta-cryptoxanthin and beta-carotene, were associated with an increased prevalence of periodontitis in this homogenous group of 60-70-year-old Western European men.
Resumo:
Cough reflex hypersensitization is a key feature in patients with troublesome cough. The clinical consequence of this hypersensitive state is typified by bouts of coughing often triggered by low threshold stimuli encountered by the patient during normal daily activities including exposure to aerosols, scents and odours, a change in air temperature and when talking or laughing. These features are often perceived by cough patients to be the most disruptive aspect of their condition and undoubtedly contribute to impaired quality of life. Patients with troublesome cough may describe a range of additional symptoms and sensations including an 'urge to cough' or the feeling of an 'itch' at the back of the throat, or a choking sensation and occasionally chest pain or breathlessness. It is uncertain if these features arise due to the processes responsible for cough reflex sensitization or as a direct consequence of the underlying cough aetiology. In an attempt to understand the clinical features of a sensitized cough reflex, the spectrum of symptoms typically described by cough patients will be reviewed and possible underlying mechanisms considered. Since an intact cough reflex is crucial to airway protection, anti-tussive treatment that attenuates the hypersensitive cough state rather than abolishing the cough reflex completely would be preferable. Identifying such agents remains a clinical, scientific and pharmacological challenge. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Considerable controversy still exists as to whether electric and magnetic fields (MF) at extremely low frequencies are genotoxic to humans. The aim of this study was to test the ability of alternating magnetic fields to induce DNA and chromosomal damage in primary human fibroblasts. Single- and double-strand breaks were quantified using the alkaline comet assay and the gammaH2AX-foci assay, respectively. Chromosomal damage was assayed for unstable aberrations, sister chromatid exchange and micronuclei. Cells were exposed to switching fields - 5min on, 10min off - for 15h over the range 50-1000microT. Exposure to ionizing radiation was used as a positive-effect calibration. In this study two separate MF exposure systems were used. One was based on a custom-built solenoid coil system and the other on a commercial system almost identical to that used in previous studies by the EU REFLEX programme. With neither system could DNA damage or chromosomal damage be detected as a result of exposure of fibroblasts to switching MF. The sensitive gammaH2AX assay could also not detect significant DNA damage in the MF-exposed fibroblasts, although the minimum threshold for this assay was equivalent to an X-ray dose of 0.025Gy. Therefore, with comparable MF parameters employed, this study could not confirm previous studies reporting significant effects for both the alkaline and neutral comet assays and chromosomal aberration induction.
Resumo:
Saturated output has been observed for both Ne and Ni-like X-ray lasers when Pumped in the transient mode. As these 'normal' transitions display very high gain, attempts have been made to observe a 2p --> 2s inner shell transition in Ne-like ions, which scale well towards the water window. Modelling of the pump conditions for Ge lasing at 6.2 run is presented. As the predicted gain is low the experiment was set up for 18 mm targets. Shots were taken on Ti, Fe, Ni and Ge. A similar to1.5 ps travelling wave pulse is applied at various times after the peak of a long, preforming Pulse. Various pump conditions were attempted but no inner shell X-ray laser was detected.
Resumo:
Results from a joint experimental and theoretical study of electron attachment to chloroform (CHCl3) molecules in the gas phase are reported. In an electron swarm study involving a pulsed Townsend technique with equal gas and electron temperatures, accurate attachment rate coefficients were determined over the temperature range 295-373 K; they show an Arrhenius-type rise with increasing temperature, corresponding to an activation energy of 0.11 (1) eV. In a high resolution electron beam experiment involving two versions of the laser photoelectron attachment method, the relative cross section for Cl- formation from CHCl3 over the energy range 0.001-1.25 eV at the gas temperature T-G = 300 K was measured. It exhibits clear downward cusp structure at the threshold for excitation of one quantum of the vibrational symmetric deformation mode nu(3), indicating that this mode is active in the primary attachment process. With reference to our thermal attachment rate coefficient k(T = 300 K) = 3.9(2) x 10(-9) cm(3) s(-1), a new highly resolved absolute attachment cross section for T-G = 300 K was determined. This cross section is extended to higher energies by measurements, carried out with a pulsed electron beam apparatus which also provided new data for the distinctly weaker fragment anions HCl2- and CCl2-. The resulting total absolute cross section for anion formation is used to calculate the dependence of the attachment rate coefficient k(T-e;T-G) on electron temperature T-e over the range 50-15000 K at the fixed gas temperature T-G = 300 K. In addition, we report the dependence of the relative cross section for Cl- formation on gas temperature T-G = 310-435 K). For comparison with the experimental data, R-matrix calculations have been carried out for the dominant anion channel Cl-. The results recover the main experimental observations and predict the dependence of the DEA cross section on the initial vibrational level nu(3) and on the vibrational temperature. Our results are compared with those of previous electron beam and electron swarm experiments.
Resumo:
AIMS/HYPOTHESIS: Atherosclerosis, which occurs prematurely in individuals with diabetes, incorporates vascular smooth muscle cell (VSMC) chemotaxis. Glucose, through protein kinase C-beta(II) signalling, increases chemotaxis to low concentrations of platelet-derived growth factor (PDGF)-BB. In VSMC, a biphasic response in PDGF-beta receptor (PDGF-betaR) level occurs as PDGF-BB concentrations increase. The purpose of this study was to determine whether increased concentrations of PDGF-BB and raised glucose level had a modulatory effect on the mitogen-activated protein kinase/extracellular-regulated protein kinase pathway, control of PDGF-betaR level and chemotaxis.
METHODS: Cultured aortic VSMC, exposed to normal glucose (NG) (5 mmol/l) or high glucose (HG) (25 mmol/l) in the presence of PDGF-BB, were assessed for migration (chemotaxis chamber) or else extracted and immunoblotted.
RESULTS: At concentrations of PDGF-BB <540 pmol/l, HG caused an increase in the level of PDGF-betaR in VSMC (immunoblotting) versus NG, an effect that was abrogated by inhibition of aldose reductase or protein kinase C-beta(II). At higher concentrations of PDGF-BB (>540 pmol/l) in HG, receptor level was reduced but in the presence of aldose reductase or protein kinase C-beta(II) inhibitors the receptor levels increased. It is known that phosphatases may be activated at high concentrations of growth factors. At high concentrations of PDGF-BB, the protein phosphatase (PP)2A inhibitor, endothall, caused an increase in PDGF-betaR levels and a loss of biphasicity in receptor levels in HG. At higher concentrations of PDGF-BB in HG, the chemoattractant effect of PDGF-BB was lost (chemotaxis chamber). Under these conditions inhibition of PP2A was associated with a restoration of chemotaxis to high concentrations of PDGF-BB.
CONCLUSION/INTERPRETATION: The biphasic response in PDGF-betaR level and in chemotaxis to PDGF-BB in HG is due to PP2A activation.
Resumo:
Universities aim for good “Space Management” so as to use the teaching space efficiently. Part of this task is to assign rooms and time-slots to teaching activities with limited numbers and capacities of lecture theaters, seminar rooms, etc. It is also common that some teaching activities require splitting into multiple events. For example, lectures can be too large to fit in one room or good teaching practice requires that seminars/tutorials are taught in small groups. Then, space management involves decisions on splitting as well as the assignments to rooms and time-slots. These decisions must be made whilst satisfying the pedagogic requirements of the institution and constraints on space resources. The efficiency of such management can be measured by the “utilisation”: the percentage of available seat-hours actually used. In many institutions, the observed utilisation is unacceptably low, and this provides our underlying motivation: to study the factors that affect teaching space utilisation, with the goal of improving it. We give a brief introduction to our work in this area, and then introduce a specific model for splitting. We present experimental results that show threshold phenomena and associated easy-hard-easy patterns of computational difficulty. We discuss why such behaviour is of importance for space management.
Resumo:
Previous studies using low frequency (1 Hz) rTMS over the motor and premotor cortex have examined repetitive movements, but focused either on motor aspects of performance such as movement speed, or on variability of the produced intervals. A novel question is whether TMS affects the synchronization of repetitive movements with an external cue (sensorimotor synchronization). In the present study participants synchronized finger taps with the tones of an auditory metronome. The aim of the study was to examine whether motor and premotor cortical inhibition induced by rTMS affects timing aspects of synchronization performance such as the coupling between the tap and the tone and error correction after a metronome perturbation. Metronome sequences included perturbations corresponding to a change in the duration of a single interval (phase shifts) that were either small and below the threshold for conscious perception (10 ms) or large and perceivable (50 ms). Both premotor and motor cortex stimulation induced inhibition, as reflected in a lengthening of the silent period. Neither motor nor premotor cortex rTMS altered error correction after a phase shift. However, motor cortex stimulation made participants tap closer to the tone, yielding a decrease in tap-tone asynchrony. This provides the first neurophysiological demonstration of a dissociation between error correction and tap-tone asynchrony in sensorimotor synchronization. We discuss the results in terms of current theories of timing and error correction.
Resumo:
Conventional methods of detecting groundwater flow zones in open boreholes installed in fractured bedrock aquifers rely on either contrasts in water quality or on significant rates of vertical flow. In low productivity boreholes these methods have proced of limited value. Tracer tests completed in six low productivity bedrock boreholes installed into fresh Precambrian crystalline bedrock revealed measurable dilution, despite very low tranmissivities. Fluorescent tracer profiles generated during discharge pumping permitted identification of the principle zones contributing to flow. High resolution acoustic televiewer strike and dip measurements of fractures corresponding to these zones revealed a consistent pattern of regional lineament trends and suggested a strongly anisotropic flow pattern in bedrock.
Resumo:
Purpose: The authors sought to quantify neighboring and distant interpoint correlations of threshold values within the visual field in patients with glaucoma. Methods: Visual fields of patients with confirmed or suspected glaucoma were analyzed (n = 255). One eye per patient was included. Patients were examined using the 32 program of the Octopus 1-2-3. Linear regression analysis among each of the locations and the rest of the points of the visual field was performed, and the correlation coefficient was calculated. The degree of correlation was categorized as high (r > 0.66), moderate (0.66 = r > 0.33), or low (r = 0.33). The standard error of threshold estimation was calculated. Results: Most locations of the visual field had high and moderate correlations with neighboring points and with distant locations corresponding to the same nerve fiber bundle. Locations of the visual field had low correlations with those of the opposite hemifield, with the exception of locations temporal to the blind spot. The standard error of threshold estimation increased from 0.6 to 0.9 dB with an r reduction of 0.1. Conclusion: Locations of the visual field have highest interpoint correlation with neighboring points and with distant points in areas corresponding to the distribution of the retinal nerve fiber layer. The quantification of interpoint correlations may be useful in the design and interpretation of visual field tests in patients with glaucoma.
Resumo:
We propose a low-complexity closed-loop spatial multiplexing method with limited feedback over multi-input-multi-output (MIMO) fading channels. The transmit adaptation is simply performed by selecting transmit antennas (or substreams) by comparing their signal-to-noise ratios to a given threshold with a fixed nonadaptive constellation and fixed transmit power per substream. We analyze the performance of the proposed system by deriving closed-form expressions for spectral efficiency, average transmit power, and bit error rate (BER). Depending on practical system design constraints, the threshold is chosen to maximize the spectral efficiency (or minimize the average BER) subject to average transmit power and average BER (or spectral efficiency) constraints, respectively. We present numerical and Monte Carlo simulation results that validate our analysis. Compared to open-loop spatial multiplexing and other approaches that select the best antenna subset in spatial multiplexing, the numerical results illustrate that the proposed technique obtains significant power gains for the same BER and spectral efficiency. We also provide numerical results that show improvement over rate-adaptive orthogonal space-time block coding, which requires highly complex constellation adaptation. We analyze the impact of feedback delay using analytical and Monte Carlo approaches. The proposed approach is arguably the simplest possible adaptive spatial multiplexing system from an implementation point of view. However, our approach and analysis can be extended to other systems using multiple constellations and power levels.
Resumo:
Loss-of-mains protection is an important component of the protection systems of embedded generation. The role of loss-of-mains is to disconnect the embedded generator from the utility grid in the event that connection to utility dispatched generation is lost. This is necessary for a number of reasons, including the safety of personnel during fault restoration and the protection of plant against out-of-synchronism reclosure to the mains supply. The incumbent methods of loss-of-mains protection were designed when the installed capacity of embedded generation was low, and known problems with nuisance tripping of the devices were considered acceptable because of the insignificant consequence to system operation. With the dramatic increase in the installed capacity of embedded generation over the last decade, the limitations of current islanding detection methods are no longer acceptable. This study describes a new method of loss-of-mains protection based on phasor measurement unit (PMU) technology, specifically using a low cost PMU device of the authors' design which has been developed for distribution network applications. The proposed method addresses the limitations of the incumbent methods, providing a solution that is free of nuisance tripping and has a zero non-detection zone. This system has been tested experimentally and is shown to be practical, feasible and effective. Threshold settings for the new method are recommended based on data acquired from both the Great Britain and Ireland power systems.
Resumo:
In this paper, we present a novel discrete cosine transform (DCT) architecture that allows aggressive voltage scaling for low-power dissipation, even under process parameter variations with minimal overhead as opposed to existing techniques. Under a scaled supply voltage and/or variations in process parameters, any possible delay errors appear only from the long paths that are designed to be less contributive to output quality. The proposed architecture allows a graceful degradation in the peak SNR (PSNR) under aggressive voltage scaling as well as extreme process variations. Results show that even under large process variations (±3σ around mean threshold voltage) and aggressive supply voltage scaling (at 0.88 V, while the nominal voltage is 1.2 V for a 90-nm technology), there is a gradual degradation of image quality with considerable power savings (71% at PSNR of 23.4 dB) for the proposed architecture, when compared to existing implementations in a 90-nm process technology. © 2006 IEEE.