The applicability of ionic liquids within the nuclear industry has been investigated. The radiation stability of ionic liquids containing dialkylimidazolium cations has been tested through with alpha, beta and gamma irradiation. The results of these tests suggest that imidazolium salts have stabilities similar to alkylbenzenes and greater than tetrabutylphosphate / odorless kerosene (TBP/OK) mixtures. The oxidative dissolution of uranium dioxide and the anodic dissolution of uranium metal and plutonium metal have been carried out in various ionic liquid media (C) 2002 American Chemical Society.
Resumo:
Introduction: Amplicon deep-sequencing using second-generation sequencing technology is an innovative molecular diagnostic technique and enables a highly-sensitive detection of mutations. As an international consortium we had investigated previously the robustness, precision, and reproducibility of 454 amplicon next-generation sequencing (NGS) across 10 laboratories from 8 countries (Leukemia, 2011;25:1840-8).
Aims: In Phase II of the study, we established distinct working groups for various hematological malignancies, i.e. acute myeloid leukemia (AML), acute lymphoblastic leukemia (ALL), chronic lymphocytic leukemia (CLL), chronic myelogenous leukemia (CML), myelodysplastic syndromes (MDS), myeloproliferative neoplasms (MPN), and multiple myeloma. Currently, 27 laboratories from 13 countries are part of this research consortium. In total, 74 gene targets were selected by the working groups and amplicons were developed for a NGS deep-sequencing assay (454 Life Sciences, Branford, CT). A data analysis pipeline was developed to standardize mutation interpretation both for accessing raw data (Roche Amplicon Variant Analyzer, 454 Life Sciences) and variant interpretation (Sequence Pilot, JSI Medical Systems, Kippenheim, Germany).
Results: We will report on the design, standardization, quality control aspects, landscape of mutations, as well as the prognostic and predictive utility of this assay in a cohort of 8,867 cases. Overall, 1,146 primer sequences were designed and tested. In detail, for example in AML, 924 cases had been screened for CEBPA mutations. RUNX1 mutations were analyzed in 1,888 cases applying the deep-sequencing read counts to study the stability of such mutations at relapse and their utility as a biomarker to detect residual disease. Analyses of DNMT3A (n=1,041) were focused to perform landscape investigations and to address the prognostic relevance. Additionally, this working group is focusing on TET2, ASXL1, and TP53 analyses. A novel prognostic model is being developed allowing stratification of AML into prognostic subgroups based on molecular markers only. In ALL, 1,124 pediatric and adult cases have been screened, including 763 assays for TP53 mutations both at diagnosis and relapse of ALL. Pediatric and adult leukemia expert labs developed additional content to study the mutation incidence of other B and T lineage markers such as IKZF1, JAK2, IL7R, PAX5, EP300, LEF1, CRLF2, PHF6, WT1, JAK1, PTEN, AKT1, IL7R, NOTCH1, CREBBP, or FBXW7. Further, the molecular landscape of CLL is changing rapidly. As such, a separate working group focused on analyses including NOTCH1, SF3B1, MYD88, XPO1, FBXW7 and BIRC3. Currently, 922 cases were screened to investigate the range of mutational burden of NOTCH1 mutations for their prognostic relevance. In MDS, RUNX1 mutation analyses were performed in 977 cases. The prognostic relevance of TP53 mutations in MDS was assessed in additional 327 cases, including isolated deletions of chromosome 5q. Next, content was developed targeting genes of the cellular splicing component, e.g. SF3B1, SRSF2, U2AF1, and ZRSR2. In BCR-ABL1-negative MPN, nine genes of interest (JAK2, MPL, TET2, CBL, KRAS, EZH2, IDH1, IDH2, ASXL1) have been analyzed in a cohort of 155 primary myelofibrosis cases searching for novel somatic mutations and addressing their relevance for disease progression and leukemia transformation. Moreover, an assay was developed and applied to CMML cases allowing the simultaneous analysis of 25 leukemia-associated target genes in a single sequencing run using just 20 ng of starting DNA. Finally, nine laboratories are studying CML, applying ultra-deep sequencing of the BCR-ABL1 tyrosine kinase domain. Analyses were performed on 615 cases investigating the dynamics of expansion of mutated clones under various tyrosine kinase inhibitor therapies.
Conclusion: Molecular characterization of hematological malignancies today requires high diagnostic sensitivity and specificity. As part of the IRON-II study, a network of laboratories analyzed a variety of disease entities applying amplicon-based NGS assays. Importantly, the consortium not only standardized assay design for disease-specific panels, but also achieved consensus on a common data analysis pipeline for mutation interpretation. Distinct working groups have been forged to address scientific tasks and in total 8,867 cases had been analyzed thus far.
Resumo:
Molecular testing is becoming an important part of the diagnosis of any patient with cancer. The challenge to laboratories is to meet this need, using reliable methods and processes to ensure that patients receive a timely and accurate report on which their treatment will be based. The aim of this paper is to provide minimum requirements for the management of molecular pathology laboratories. This general guidance should be augmented by the specific guidance available for different tumour types and tests. Preanalytical considerations are important, and careful consideration of the way in which specimens are obtained and reach the laboratory is necessary. Sample receipt and handling follow standard operating procedures, but some alterations may be necessary if molecular testing is to be performed, for instance to control tissue fixation. DNA and RNA extraction can be standardised and should be checked for quality and quantity of output on a regular basis. The choice of analytical method(s) depends on clinical requirements, desired turnaround time, and expertise available. Internal quality control, regular internal audit of the whole testing process, laboratory accreditation, and continual participation in external quality assessment schemes are prerequisites for delivery of a reliable service. A molecular pathology report should accurately convey the information the clinician needs to treat the patient with sufficient information to allow for correct interpretation of the result. Molecular pathology is developing rapidly, and further detailed evidence-based recommendations are required for many of the topics covered here.
Resumo:
The University of Waikato, Hamilton, New Zealand and The Queen's University of Belfast, Northern Ireland radiocarbon dating laboratories have undertaken a series of high-precision measurements on decadal samples of dendrochronologically dated oak (Quercus petraea) from Great Britain and cedar (Libocedrus bidwillii) and silver pine (Lagarostrobos colensoi) from New Zealand. The results show an average hemispheric offset over the 900 yr of measurement of 40±13 yr. This value is not constant but varies with a periodicity of about 130 yr. The Northern Hemisphere measurements confirm the validity of the Pearson et al. (1986) calibration dataset.
Resumo:
The ingress of chlorides into concrete is predominantly by the mechanism of diffusion and the resistance of concrete to the transport of chlorides is generally represented by its coefficient of diffusion. The determination of this coefficient normally requires long test duration (many months). Therefore, rapid test methods based on the electrical migration of ions have widely been used. The current procedure of chloride ion migration tests involves placing a concrete disc between an ion source solution and a neutral solution and accelerating the transport of ions from the source solution to the neutral solution by the application of a potential difference across the concrete disc. This means that, in order to determine the chloride transport resistance of concrete cover, cores should be extracted from the structure and tested in laboratories. In an attempt to facilitate testing of the concrete cover on site, an in situ ion migration test (hereafter referred to as PERMIT ion migration test for the unique identification of the new test) was developed. The PERMIT ion migration test was validated in the lab by carrying out a comparative investigation and correlating the results with the migration coefficient from the one-dimensional chloride migration test, the effective diffusion coefficient from the normal diffusion test and the apparent diffusion coefficient determined from chloride profiles. A range of concrete mixes made with ordinary Portland cement was used for this purpose. In addition, the effects of preferential flow of ions close to the concrete surface and the proximity of reinforcement within the test area on the in situ migration coefficients were investigated. It was observed that the in situ migration index, found in one working day, correlated well with the chloride diffusion coefficients from other tests. The quality of the surface layer of the cover concrete and the location of the reinforcement within the test area were found to affect the flow of ions through the concrete during the test. Based on the data, a procedure to carry out the PERMIT ion migration test was standardised.
Resumo:
Polymerase chain reaction (PCR) assessment of clonal immunoglobulin (Ig) and T-cell receptor (TCR) gene rearrangements is an important diagnostic tool in mature B-cell neoplasms. However, lack of standardized PCR protocols resulting in a high level of false negativity has hampered comparability of data in previous clonality studies. In order to address these problems, 22 European laboratories investigated the Ig/TCR rearrangement patterns as well as t(14;18) and t(11;14) translocations of 369 B-cell malignancies belonging to five WHO-defined entities using the standardized BIOMED-2 multiplex PCR tubes accompanied by international pathology panel review. B-cell clonality was detected by combined use of the IGH and IGK multiplex PCR assays in all 260 definitive cases of B-cell chronic lymphocytic leukemia (n¼56), mantle cell lymphoma (n¼54), marginal zone lymphoma (n¼41) and follicular lymphoma (n¼109). Two of 109 cases of diffuse large B-cell lymphoma showed no detectable clonal marker. The use of these techniques to assign cell lineage should be treated with caution as additional clonal TCR gene rearrangements were frequently detected in all disease categories. Our study indicates that the BIOMED-2 multiplex PCR assays provide a powerful strategy for clonality assessment in B-cell malignancies resulting in high Ig clonality detection rates particularly when IGH and IGK strategies are combined.
Resumo:
Index properties such as the liquid limit and plastic limit are widely used to evaluate certain geotechnical parameters of fine-grained soils. Measurement of the liquid limit is a mechanical process, and the possibility of errors occurring during measurement is not significant. However, this is not the case for plastic limit testing, despite the fact that the current method of measurement is embraced by many standards around the world. The method in question relies on a fairly crude procedure known widely as the ‘thread rolling' test, though it has been the subject of much criticism in recent years. It is essential that a new, more reliable method of measuring the plastic limit is developed using a mechanical process that is both consistent and easily reproducible. The work reported in this paper concerns the development of a new device to measure the plastic limit, based on the existing falling cone apparatus. The force required for the test is equivalent to the application of a 54 N fast-static load acting on the existing cone used in liquid limit measurements. The test is complete when the relevant water content of the soil specimen allows the cone to achieve a penetration of 20 mm. The new technique was used to measure the plastic limit of 16 different clays from around the world. The plastic limit measured using the new method identified reasonably well the water content at which the soil phase changes from the plastic to the semi-solid state. Further evaluation was undertaken by conducting plastic limit tests using the new method on selected samples and comparing the results with values reported by local site investigation laboratories. Again, reasonable agreement was found.
Resumo:
The single-cell gel electrophoresis technique or comet assay is widely regarded as a quick and reliable method of analysing DNA damage in individual cells. It has a proven track record from the fields of biomonitoring to nutritional studies. The assay operates by subjecting cells that are fixed in agarose to high salt and detergent lysis, thus removing all the cellular content except the DNA. By relaxing the DNA in an alkaline buffer, strands containing breaks are released from supercoiling. Upon electrophoresis, these strands are pulled out into the agarose, forming a tail which, when stained with a fluorescent dye, can be analysed by fluorescence microscopy. The intensity of this tail reflects the amount of DNA damage sustained. Despite being such an established and widely used assay, there are still many aspects of the comet assay which are not fully understood. The present review looks at how the comet assay is being used, and highlights some of its limitations. The protocol itself varies among laboratories, so results from similar studies may vary. Given such discrepancies, it would be attractive to break the assay into components to generate a mathematical model to investigate specific parameters.
Resumo:
Yeasts and filamentous fungi are beginning to emerge as significant microbial pathogens in patients with cystic fibrosis (CF), particularly in relation to allergic-type responses, as seen in patients with allergic bronchopulmonary aspergillosis (ABPA), Aspergillus bronchitis and in invasive fungal disease in lung transplant patients. Four fungal media were compared in this study, including Sabouraud Dextrose Agar (SDA) and Medium B, with and without the addition of selective antibiotics, where antibiotic-supplemented media were designated with (+). These media were compared for their ability to suppress contaminating, mainly Gram-ve pathogens, in CF sputa (Pseudomonas aeruginosa, Burkholderia cepacia complex [BCC] organisms) and to enhance the growth of fungi present in CF sputum. Medium B consisted of glucose (16.7 g/l), agar (20 g/l), yeast extract (30 g/l) and peptone (6.8 g/l) at pH 6.3 and both SDA(+) and Medium B+ were supplemented with cotrimethoxazole, 128 mg/l; chloramphenicol, 50 mg/l; ceftazidime, 32 mg/l; colistin, 24 mg/l). Employment of SDA(+) or Medium B+ allowed an increase in specificity in the detection of yeasts and moulds, by 42.8% and 39.3%, respectively, over SDA when used solely. SDA(+) had a greater ability than Medium B+ to suppress bacterial growth from predominantly Gram-ve co-colonisers. This is a significant benefit when attempting to detect and isolate fungi from the sputum of CF patients, as it largely suppressed any bacterial growth, with the exception of the BCC organisms, thus allowing for an increased opportunity to detect target fungal organisms in sputum and represented a significant improvement over the commercial medium (SDA), which is currently used. Overall, both novel selective media were superior in their ability to suppress bacteria in comparison with the commercially available SDA medium, which is routinely employed in most clinical microbiology diagnostic laboratories presently. Alternatively, Medium B+ had a great ability to grow fungi than SDA(+) and when employed together, the specificity of combined use was 82%, with a sensitivity for yeasts, filamentous fungi, and combined overall fungi of 96.0%, 92.3% and 96.0%, respectively. Overall, when employing one fungal selective medium for the routine detection of yeasts and filamentous fungi in the sputum of CF patients, we would recommend employment of Medium B+. However, we would recommend the combined employment of SDA(+) and Medium B+, in order to synergistically isolate and detect the greatest number of fungi present in CF sputa. (C) 2008 European Cystic Fibrosis Society. Published by Elsevier B.V All rights reserved.
Resumo:
An in vitro method of determining the activity of antibiotics in combination which is simple and convenient to perform and which could be used routinely in clinical microbiology laboratories is desirable. We investigated the activity, against Pseudomonas aeruginosa and Burkholderia cepacia complex clinical isolates, of ceftazidime and tobramycin in combination using a broth macrodilution sensitivity method based on breakpoint minimum inhibitory concentrations and compared the results obtained using this method with those obtained using the microtitre checkerboard method. There was good agreement in interpretation of results between the two methods for both P. aeruginosa (90%) and B. cepacia complex isolates (70%) with tobramycin and for P. aeruginosa isolates (70%) with ceftazidime. As the breakpoint combination sensitivity testing method employs only four tubes and does not require initial determination of individual antibiotic minimum inhibitory concentrations, it is simpler and more convenient for determining the activity of antibiotics in combination than the microtitre checkerboard method. The use of this method in routine microbiology laboratories to determine the activity of antibiotic combinations against clinical isolates should optimise treatment of infection by ensuring that appropriate antibiotic combinations are prescribed. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Past measurements of the radiocarbon interhemispheric offset have been restricted to relatively young samples because of a lack of older dendrochronologically secure Southern Hemisphere tree-ring chronologies. The Southern Hemisphere calibration data set SHCal04 earlier than AD 950 utilizes a variable interhemispheric offset derived from measured 2nd millennium AD Southern Hemisphere/Northern Hemisphere sample pairs with the assumption of stable Holocene ocean/ atmosphere interactions. This study extends the range of measured interhemispheric offset values with 20 decadal New Zealand kauri and Irish oak sample pairs from 3 selected time intervals in the 1st millennium AD and is part of a larger program to obtain high-precision Southern Hemisphere 14C data continuously back to 200 BC. We found an average interhemispheric offset of 35 ± 6 yr, which although consistent with previously published 2nd millennium AD measurements, is lower than the offset of 55–58 yr utilized in SHCal04. We concur with McCormac et al. (2008) that the IntCal04 measurement for AD 775 may indeed be slightly too old but also suggest the McCormac results appear excessively young for the interval AD 755–785. In addition, we raise the issue of laboratory bias and calibration errors, and encourage all laboratories to check their consistency with appropriate calibration curves and invest more effort into improving the accuracy of those curves.