3 resultados para joint motion

em QSpace: Queen's University - Canada


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Measuring and tracking athletic performance is crucial to an athlete’s development and the countermovement vertical jump is often used to measure athletic performance, particularly lower limb power. The linear power developed in the lower limb is estimated through jump height. However, the relationship between angular power, produced by the joints of the lower limb, and jump height is not well understood. This study examined the contributions of the kinetic value of angular power, and its kinematic component, angular velocity, of the lower limb joints to jump height in the countermovement vertical jump. Kinematic and kinetic data were gathered from twenty varsity-level basketball and volleyball athletes as they performed six maximal effort jumps in four arm swing conditions: no-arm involvement, single-non-dominant arm swing, single-dominant arm swing, and two-arm swing. The displacement of the whole body centre of mass, peak joint powers, peak angular velocity, and locations of the peaks as a percentage of the jump’s takeoff period, were computed. Linear regressions assessed the relationship of the variables to jump height. Results demonstrated that knee peak power (p = 0.001, ß = 0.363, r = 0.363), its location within takeoff period (p = 0.023, ß = -0.256, r = 0.256), and peak knee peak angular velocity (p = 0.005, ß = 0.310, r = 0.310) were moderately linked to increased jump height. Additionally, the location, within the takeoff period, of the peak angular velocities of the hip (p = 0.003, ß = -0.318, r = 0.419) and ankle (p = 0.011, ß = 0.270, r = 0.419) were positively linked to jump height. These results highlight the importance of training the velocity and timing of joint motion beyond traditional power training protocols as well as the importance of further investigation into appropriate testing protocol that is sensitive to the contributions by individual joints in maximal effort jumping.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles.