41 resultados para numerical model
Resumo:
This paper discusses an optimisation based decision support system and methodology for electronic packaging and product design and development which is capable of addressing in efficient manner specified environmental, reliability and cost requirements. A study which focuses on the design of a flip-chip package is presented. Different alternatives for the design of the flip-chip package are considered based on existing options for the applied underfill and volume of solder material used to form the interconnects. Variations in these design input parameters have simultaneous effect on package aspects such as cost, environmental impact and reliability. A decision system for the design of the flip-chip that uses numerical optimisation approach is used to identify the package optimal specification which satisfies the imposed requirements. The reliability aspect of interest is the fatigue of solder joints under thermal cycling. Transient nonlinear finite element analysis (FEA) is used to simulate the thermal fatigue damage in solder joints subject to thermal cycling. Simulation results are manipulated within design of experiments and response surface modelling framework to provide numerical model for reliability which can be used to quantify the package reliability. Assessment of the environmental impact of the package materials is performed by using so called Toxic Index (TI). In this paper we demonstrate the evaluation of the environmental impact only for underfill and lead-free solder materials. This evaluation is based on the amount of material per flip-chip package. Cost is the dominant factor in contemporary flip-chip packaging industry. In the optimisation based decision support system for the design of the flip-chip package, cost of materials which varies as a result of variations in the design parameters is considered.
Resumo:
Design for manufacture of system-in-package (SiP) structures is dependent on a number of physical processes that affect the final quality of the package in terms of its performance and reliability. Solder joints are key structures in a SiP and their behavior can be the critical factor in terms of reliability. This paper discusses the results from a research programme on design for manufacturing of system in package (SiP) technologies. The focus of the paper is on thermo-mechanical modelling of solder joints. This includes the behavior of the joints during testing plus some important insights into the reflow process and how physical phenomena taking place at the assembly stage can affect solder joint behavior. Finite element analysis of a numerical model of an SiP structure with various design parameters is discussed. The goal of this analysis is to identify the most promising combination of design parameters which guarantee longer lifetime of the solder joints and hence the SiP component. The parameters that were studied are the size of the package (i.e. number of solder joints per row), the presence of the underfill and/or the reinforcement as well as the thickness of the passive die. Discussion was also provided on phenomena that take place during the reflow process where the solder joints are formed. In particular, the formation of intermetallics at the solder-pad interfaces
Resumo:
Methods for serial generation of droplets from a liquid jet are shortly reviewed. A method of liquid metal droplet generation based on AC high frequency magnetic field is considered in detail. Numerical model for direct simulation of the time dependent droplet generation process is presented. Computed examples demonstrate the liquid silicon droplet formation for the cases of 500-1500 μm diameter.
Resumo:
The waves in commercial cells for electrolytic aluminium production originate at the interface between the liquid aluminium and electrolyte, but their effect can spread into the surrounding busbar network as electric current perturbation, and the total magnetic field acquires a time dependent component. The presented model for the wave development accounts for the nonuniform electric current distribution at the cathode and the whole network of the surrounding busbars. The magnetic field is computed for the continuous current in the fluid zones, all busbars and the ferromagnetic construction elements. When the electric current and the associated magnetic field are computed according to the actual electrical circuit and updated for all times, the instability growth rate is significantly affected. The presented numerical model for the wave and electromagnetic interaction demonstrates how different physical coupling factors are affecting the wave development in the electrolysis cells. These small amplitude self-sustained interface oscillations are damped in the presence of intense turbulent viscosity created by the horizontal circulation velocity field. Additionally, the horizontal circulation vortices create a pressure gradient contributing to the deformation of the interface. Instructive examples for the 500 kA demonstration cell are presented.
Resumo:
The time dependent numerical model of cold crucible melting is based on the coupled electromagnetic, temperature and turbulent velocity field calculation accounting for the magnetically confined liquid metal shape continuous change. The model is applied to investigate the process energy efficiency dependence on the critical choice of AC power supply frequency and an optional addition of a DC magnetic field. Test cases of the metal load up to 50 kg are considered. The behaviour of the numerical model at high AC frequencies is instructively validated by the use of the electromagnetic analytical solution for a sphere and temperature measurements in a commercial size cold crucible furnace
Resumo:
Purpose – This paper aims to present an open-ended microwave curing system for microelectronics components and a numerical analysis framework for virtual testing and prototyping of the system, enabling design of physical prototypes to be optimized, expediting the development process. Design/methodology/approach – An open-ended microwave oven system able to enhance the cure process for thermosetting polymer materials utilised in microelectronics applications is presented. The system is designed to be mounted on a precision placement machine enabling curing of individual components on a circuit board. The design of the system allows the heating pattern and heating rate to be carefully controlled optimising cure rate and cure quality. A multi-physics analysis approach has been adopted to form a numerical model capable of capturing the complex coupling that exists between physical processes. Electromagnetic analysis has been performed using a Yee finite-difference time-domain scheme, while an unstructured finite volume method has been utilized to perform thermophysical analysis. The two solvers are coupled using a sampling-based cross-mapping algorithm. Findings – The numerical results obtained demonstrate that the numerical model is able to obtain solutions for distribution of temperature, rate of cure, degree of cure and thermally induced stresses within an idealised polymer load heated by the proposed microwave system. Research limitations/implications – The work is limited by the absence of experimentally derived material property data and comparative experimental results. However, the model demonstrates that the proposed microwave system would seem to be a feasible method of expediting the cure rate of polymer materials. Originality/value – The findings of this paper will help to provide an understanding of the behaviour of thermosetting polymer materials during microwave cure processing.
Resumo:
In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems
Resumo:
The effects of a constant uniform magnetic field on thermoelectric currents during dendritic solidification were investigated using a 2-dimensional enthalpy based numerical model. Using an approximation of the dendrite growing in free space it was found that the resulting Lorentz force generates a circulating flow influencing the solidification pattern. As the magnetic field strength increases it was found that secondary growth on the clockwise side of the primary arm of the dendrite was encouraged, while the anticlockwise side is suppressed due to a reduction in local free energy. The preferred direction of growth rotated in the clockwise sense under an anti-clockwise flow for both the binary alloy and pure material. The tip velociy is significantly increased compared to growth in stagnant flow. This is due to a small recirculation that follows the tip of the dendrite; bringing in colder liquid and lower concentrations of solute. The recirculation being not normally incident on the tip is most likely the cause for the rotation. Grain growth consisting of multiple seeds with the same anisotropy growing in the same plane, gives a competition to release latent heat resulting in stunted growth. The initial growth for each dendrite is very similar to the single seed cases indicating that dendrites must become before the thermoelectric interactions are significant.
Resumo:
The numerical model for electrically conducting liquid droplets levitated in AC magnetic field is extended to demonstrate various factors affecting the accuracy of material property value measurements. The effects included are the electromagnetic force induced stirring and the resulting turbulence, thermo-capillary convection, and the droplet rotation. The results are validated against available analytical solutions.
Resumo:
The effects of a constant uniform magnetic field on dendritic solidification were investigated using a 2-dimensional enthalpy based numerical model. The interaction between thermoelectic currents and the magnetic field generates a Lorentz force that creates a flow. This flow causes a change in the morphology of the dendrite; secondary growth is promoted on one side of the dendrite arm and the tip velocity of the primary arm is increased.
Resumo:
In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems.
Resumo:
Comparison of the performance of a conventional convection oven system with a dual-section microwave system for curing thermosetting polymer encapsulant materials has been performed numerically. A numerical model capable of analysing both the convection and microwave cure processes has been developed and is breifly outliines. The model is used to analyse the curing of a commercially available encapsulant material using both systems. Results obtained from numerical solutions are presented, confirming that the VFM system enables the cure process to be carried out far more rapidly than with the convection oven system. This capability stems from the fundamental heating processes involved, namely that microwave processing enables the heating rate to be varied independently of the material temperature. Variations in cure times, curing rates, maximum temperatures and residual stresses between the processes are fully discussed.
Resumo:
The curing of a thermosetting polymer materials utilized on micro-electronics packaging applications can be performed using microwave systems. The use of microwave energy enables the cure process to be completed more rapidly than with alternative approaches due to the ability to heat volumetrically. Furthermore, advanced dual-section microwave systems enable curing of individual components on a chip-on-board assembly. The dielectric properties of thermosetting polymer materials, commonly used in microelectronics packaging applications, vary significantly with temperature and degree of cure. The heating rate within a material subjected to an electric field is primarily dependant on the dielectric loss properties of the material itself. This article examines the variation in dielectric properties of a commercially available encapsulant paste with frequency and temperature and the resulting influence on the cure process. The 'FAMOBS' dual section microwave system and its application to microelectronics manufacture are described. The measurement of the dielectric properties of 'Henkel EO1080' encapsulant paste uses a commercially available 'dielectric probe kit' and is described in this paper. The FAMOBS heating system is used to encapsulate a small op-amp chip. A numerical model formulated to assess the cure process in thermosetting polymer materials under microwave heating is outlined. Numerical results showing that the microwave processing systems is capable of rapidly and evenly curing thermosetting polymer materials are presented.
Resumo:
Bulk and interdendritic flow during solidification alters the microstructure development, potentially leading to the formation of defects. In this paper, a 3D numerical model is presented for the simulation of dendritic growth in the presence of fluid flow in both liquid and semi-solid zones during solidification. The dendritic growth was solved by the combination of a stochastic nucleation approach with a finite difference solution of the solute diffusion equation and. a projection method solution of the Navier-Stokes equations. The technique was applied first to simulate the growth of a single dendrite in 2D and 3D in an isothermal environment with forced fluid flow. Significant differences were found in the evolution of dendritic morphology when comparing the 2D and 3D results. In 3D the upstream arm has a faster growth velocity due to easier flow around the perpendicular arms. This also promotes secondary arm formation on the upstream arm. The effect of fluid flow on columnar dendritic growth and micro-segregation in constrained solidification conditions is then simulated. For constrained growth, 2D simulations lead to even greater inaccuracies as compared to 3D.
Resumo:
Thermoelectric currents in the presence of a magnetic field generate Lorentz forces which can drive fluid flow. In the case of dendritic growth a naturally occurring thermoelectric current exists and in the presence of a high magnetic field micro convections are generated. Experimental evidence has attributed changes in microstructure to this effect. A numerical model has been developed to study the flow field around an unconstricted equiaxed dendrite growing under these conditions. The growth is modeled in 2D and 3D by an enthalpy based method and a complex flow structure has been predicted. Using a pseudo-3D approximation for economy, realistic 2D simulations are obtained where a fully coupled transient scheme reveals significant changes to the dendrite morphology reflecting experimental evidence. There is a rotation of the preferred direction of growth and increased secondary branching.