3 resultados para Impedance Matching

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using data on user attributes and interactions from an online dating site, we estimate mate preferences, and use the Gale-Shapley algorithm to predict stable matches. The predicted matches are similar to the actual matches achieved by the dating site, and the actual matches are approximately efficient. Out-of-sample predictions of offline matches, i.e., marriages, exhibit assortative mating patterns similar to those observed in actual marriages. Thus, mate preferences, without resort to search frictions, can generate sorting in marriages. However, we underpredict some of the correlation patterns; search frictions may play a role in explaining the discrepancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of the New York City (NYC) high school match involved trade-offs among efficiency, stability, and strategy-proofness that raise new theoretical questions. We analyze a model with indifferences-ties-in school preferences. Simulations with field data and the theory favor breaking indifferences the same way at every school-single tiebreaking-in a student-proposing deferred acceptance mechanism. Any inefficiency associated with a realized tiebreaking cannot be removed without harming student incentives. Finally, we empirically document the extent of potential efficiency loss associated with strategy-proofness and stability, and direct attention to some open questions. (JEL C78, D82, I21).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Telecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS-Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and the use of a 'solid tank' (which reduces noise, and the volume of refractively matched fluid from 1 ltr to 10 cc). The efficacy of DFOS was evaluated by direct comparison against commissioned scanners in our lab. Measured dose distributions from all systems were compared against the predicted dose distributions from a commissioned treatment planning system (TPS). Three treatment plans were investigated including a simple four-field box treatment, a multiple small field delivery, and a complex IMRT treatment. Dosimeters were imaged within 2 h post irradiation, using consistent scanning techniques (360 projections acquired at 1 degree intervals, reconstruction at 2mm). DFOS efficacy was evaluated through inspection of dose line-profiles, and 2D and 3D dose and gamma maps. DFOS/TPS gamma pass rates with 3%/3mm dose difference/distance-to-agreement criteria ranged from 89.3% to 92.2%, compared to from 95.6% to 99.0% obtained with the commissioned system. The 3D gamma pass rate between the commissioned system and DFOS was 98.2%. The typical noise rates in DFOS reconstructions were up to 3%, compared to under 2% for the commissioned system. In conclusion, while the introduction of a solid tank proved advantageous with regards to cost and convenience, further work is required to improve the image quality and dose reconstruction accuracy of the new DFOS optical-CT system.