3 resultados para second derivative
em DI-fusion - The institutional repository of Université Libre de Bruxelles
Resumo:
The adsorption of biadipate on Au(111) was studied by cyclic voltammetry and chronocoulometry. The biadipate adlayer undergoes a potential-driven phase transition. It is shown that the phase transition can be either of the first- or second-order depending on the biadipate concentration. At low surfactant concentrations, the first-order transition is characterised by a discontinuity in the charge density-potential curve and by the presence of very sharp peaks in the voltammetric response. At higher concentrations, these peaks are no longer observed but a discontinuity in the capacity curve is still noticeable, in agreement with a second-order transition. © the Owner Societies.
Resumo:
Anti-neutrophil cytoplasmic antibodies (ANCA) are diagnostic markers for systemic vasculitis. They are classically I detected by an indirect immunofluorescence test using normal donor neutrophils as substrate. This assay lacks antigenic specificity and is not quantitative. The 'EC/BCR Project for ANCA Assay Standardization' is an international collaboration study with the aim to develop and standardize solid phase assays for ANCA detection. In this part of the study the isolation and characterization of proteinase-3 and myeloperoxidase, the two main target molecules for ANCA, and the development and standardization of ELISAs with these antigens are described. Six laboratories successfully isolated purified proteinase-3 preparations that could be used. Three of these preparations, together with one myeloperoxidase preparation, were subsequently used for ANCA testing by ELISA. The ELISA technique was standardized in two rounds of testing in the 14 participating laboratories. The coefficient of variation of these new assays decreased from values of approx. 50% in the first round to approx. 20% in the second round. We conclude that purified proteinase-3 and myeloperoxidase can be used in standardized ELISAs for ANCA detection. Whether such procedures offer advantages over the IIF test will be determined in a prospective clinical study.
Resumo:
The second round of the community-wide initiative Critical Assessment of automated Structure Determination of Proteins by NMR (CASD-NMR-2013) comprised ten blind target datasets, consisting of unprocessed spectral data, assigned chemical shift lists and unassigned NOESY peak and RDC lists, that were made available in both curated (i.e. manually refined) or un-curated (i.e. automatically generated) form. Ten structure calculation programs, using fully automated protocols only, generated a total of 164 three-dimensional structures (entries) for the ten targets, sometimes using both curated and un-curated lists to generate multiple entries for a single target. The accuracy of the entries could be established by comparing them to the corresponding manually solved structure of each target, which was not available at the time the data were provided. Across the entire data set, 71 % of all entries submitted achieved an accuracy relative to the reference NMR structure better than 1.5 Å. Methods based on NOESY peak lists achieved even better results with up to 100 % of the entries within the 1.5 Å threshold for some programs. However, some methods did not converge for some targets using un-curated NOESY peak lists. Over 90 % of the entries achieved an accuracy better than the more relaxed threshold of 2.5 Å that was used in the previous CASD-NMR-2010 round. Comparisons between entries generated with un-curated versus curated peaks show only marginal improvements for the latter in those cases where both calculations converged.