7 resultados para DECOUPLED BANDS
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
This paper deals with the monolithic decoupled XYZ compliant parallel mechanisms (CPMs) for multi-function applications, which can be fabricated monolithically without assembly and has the capability of kinetostatic decoupling. At first, the conceptual design of monolithic decoupled XYZ CPMs is presented using identical spatial compliant multi-beam modules based on a decoupled 3-PPPR parallel kinematic mechanism. Three types of applications: motion/positioning stages, force/acceleration sensors and energy harvesting devices are described in principle. The kinetostatic and dynamic modelling is then conducted to capture the displacements of any stage under loads acting at any stage and the natural frequency with the comparisons with FEA results. Finally, performance characteristics analysis for motion stage applications is detailed investigated to show how the change of the geometrical parameter can affect the performance characteristics, which provides initial optimal estimations. Results show that the smaller thickness of beams and larger dimension of cubic stages can improve the performance characteristics excluding natural frequency under allowable conditions. In order to improve the natural frequency characteristic, a stiffness-enhanced monolithic decoupled configuration that is achieved through employing more beams in the spatial modules or reducing the mass of each cubic stage mass can be adopted. In addition, an isotropic variation with different motion range along each axis and same payload in each leg is proposed. The redundant design for monolithic fabrication is introduced in this paper, which can overcome the drawback of monolithic fabrication that the failed compliant beam is difficult to replace, and extend the CPM’s life.
Resumo:
This paper deals with a completely kinematostaticaly decoupled XY compliant parallel manipulator (CPM) composed of exactly-constrained compliant modules. A new 4-PP XY translational parallel mechanism (TPM) with a new topology structure is firstly proposed where each two P (P: prismatic) joints on the base in two non-adjacent legs are rigidly connected. A novel 4-PP XY CPM is then obtained by replacing each traditional P join on the base in the 4-PP XY TPM with a compound basic parallelogram module (CBPM) and replacing each traditional P joint on the motion stage with a basic parallelogram module (BPM). Approximate analytical model is derived with comparison to the FEA (finite element analysis) model and experiment for a case study. The proposed novel XY CPM has a compact configuration with good dynamics, and is able to well constrain the parasitic rotation and the cross-axis coupling of the motion stage. The cross-axis motion of the input stage can be completely eliminated, and the lost motion between the input stage and the motion stage is significantly reduced.
Resumo:
This paper deals with the conceptual design of decoupled, compact, and monolithic XYZ compliant parallel manipulators (CPMs): CUBEs. Position spaces of compliant P (P: prismatic) joints are first discussed, which are represented by circles about the translational directions. A design method of monolithic XYZ CPMs is then proposed in terms of both the kinematic substitution method and the position spaces. Three types of monolithic XYZ CPMs are finally designed using the proposed method with the help of three classes of kinematical decoupled 3-DOF (degree of freedom) translational parallel mechanisms (TPMs). These monolithic XYZ CPMs include a 3-PPP XYZ CPM composed of identical parallelogram modules (a previously reported design), a novel 3-PPPR (R: revolute) XYZ CPM composed of identical compliant four-beam modules, and a novel 3-PPPRR XYZ CPM. The latter two monolithic designs also have extended lives. It is shown that the proposed design method can be used to design other decoupled and compact XYZ CPMs by using the concept of position spaces, and the resulting XYZ CPM is the most compact one when the fixed ends of the three actuated compliant P joints thereof overlap.
Resumo:
This paper introduces a screw theory based method termed constraint and position identification (CPI) approach to synthesize decoupled spatial translational compliant parallel manipulators (XYZ CPMs) with consideration of actuation isolation. The proposed approach is based on a systematic arrangement of rigid stages and compliant modules in a three-legged XYZ CPM system using the constraint spaces and the position spaces of the compliant modules. The constraint spaces and the position spaces are firstly derived based on the screw theory instead of using the rigid-body mechanism design experience. Additionally, the constraint spaces are classified into different constraint combinations, with typical position spaces depicted via geometric entities. Furthermore, the systematic synthesis process based on the constraint combinations and the geometric entities is demonstrated via several examples. Finally, several novel decoupled XYZ CPMs with monolithic configurations are created and verified by finite elements analysis. The present CPI approach enables experts and beginners to synthesize a variety of decoupled XYZ CPMs with consideration of actuation isolation by selecting an appropriate constraint and an optimal position for each of the compliant modules according to a specific application.
Resumo:
In this study I examine the development of three inclusive music bands in Cork city. Derived from Jellison’s research on inclusive music education, inclusive music bands involve students with disabilities coming together with typically developing peers to make and learn music that is meaningful (Jellison, 2012). As part of this study, I established three inclusive music bands to address the lack of inclusive music making and learning experiences in Cork city. Each of these bands evolved and adapted in order to be socio-culturally relevant within formal and informal settings: Circles (community education band), Till 4 (secondary school band) and Mish Mash (third level and community band). I integrated Digital Musical Instruments into the three bands, in order to ensure access to music making and learning for band members with profound physical disabilities. Digital Musical Instruments are electronic music devices that facilitate active music making with minimal movement. This is the first study in Ireland to examine the experiences of inclusive music making and learning using Digital Musical Instruments. I propose that the integration of Digital Musical Instruments into inclusive music bands has the potential to further the equality and social justice agenda in music education in Ireland. In this study, I employed qualitative research methodology, incorporating participatory action research methodology and case study design. In this thesis I reveal the experiences of being involved in an inclusive music band in Cork city. I particularly focus on examining whether the use of this technology enhances meaningful music making and learning experiences for members with disabilities within inclusive environments. To both inform and understand the person centered and adaptable nature of these inclusive bands, I draw theoretical insights from Sen’s Capabilities Approach and Deleuze and Guatarri’s Rhizome Theory. Supported by descriptive narrative from research participants and an indepth examination of literature, I discover the optimum conditions and associated challenges of inclusive music practice in Cork city.
Resumo:
This paper reports the results of the on-body experimental tests of a set of four planar differential antennas, originated by design variations of radiating elements with the same shape and characterized by the potential for covering wide and narrow bands. All the antenna designs have been implemented on low-cost FR4 substrate and characterized experimentally through on-body measurements. The results show the impact of the proximity to the human body on antenna performance and the opportunities in terms of potential coverage of wide and narrow bands for future ad hoc designs and implementations through wearable substrates targeting on-body and off-body communication and sensing applications.
Resumo:
Background: Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. :Objectives: To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of: (1) how often the bands come off during treatment; and (2) whether they protect the banded teeth against decay during fixed appliance treatment. Search methods: The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Selection criteria: Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. Data collection and analysis: All review authors were involved in study selection, validity assessment and data extraction without blinding to the authors, adhesives used or results obtained. All disagreements were resolved by discussion. Main results: Five RCTs and three CCTs were identified as meeting the review's inclusion criteria. All the included trials were of split-mouth design. Four trials compared chemically cured zinc phosphate and chemically cured glass ionomer; three trials compared chemically cured glass ionomer cement with light cured compomer; one trial compared chemically cured glass ionomer with a chemically cured glass phosphonate. Data analysis was often inappropriate within the studies meeting the inclusion criteria. Authors' conclusions: There is insufficient high quality evidence with regard to the most effective adhesive for attaching orthodontic bands to molar teeth. Further RCTs are required.