7 resultados para Standard Reference Intervals
em Biblioteca Digital da Produ
Resumo:
Background To better characterize the pathophysiology of juvenile nasopharyngeal angiofibroma (JNA), endothelial and stromal cells were evaluated by genomic imbalances in association with transcript expression levels of genes mapped on these altered regions. Methods. High-resolution comparative genomic hybridization (HR-CGH) was used in laser-captured endothelial and stromal cells from 9 JNAs. Ten genes were evaluated by quantitative real-timereverse transcription polymerase chain reaction (qRT-PCR) in 15 cases. Results. Although gains were more frequently detected in endothelial cells, 57% of chromosomal alterations were common by both components. Gene expression analyses revealed a positive correlation between endothelial and stromal components for ASPM, CDH1, CTNNB1, FGF18, and SUPT16H. A significant difference was found for FGF18 and AURKB overexpression in stromal cells and AR down-expression in endothelial cells. Conclusions. A similar pattern of gene expression and chromosomal imbalances in both exponents would suggest a common mechanism of functional regulation. AURKB, FGF18, and SUPT16H were identified as potential molecular markers in JNA. (C) 2011 Wiley Periodicals, Inc. Head Neck 34: 485-492, 2012
Resumo:
The use of standard reference electrodes, such as Ag/AgCl or saturated calomel electrodes, in potentiometric and amperometric studies involving miniaturized electrochemical systems, or those operating under positive hydraulic pressure, is often impractical. Placement of the reference electrode in the direct vicinity of the working electrode is often prohibited by the dimensions or layout of the electrochemical cell, while the alternative strategy of locating the reference electrode in a separate compartment often leads to electrolyte leakage and contamination of the system. In the present study, we have investigated the functionality of a pseudoreference electrode comprising a platinum wire, one end of which was maintained in intimate contact with the internal solution of an Ag/AgCl reference electrode while the other was connected, via a BNC connector, to a platinum probe located within the electrochemical cell. Linear and cyclic voltammetric studies, involving both aqueous and nonaqueous electrolytes, were carried out using the pseudoreference electrode and an electrochemical cup-type cell with three electrodes or an electrochemical flow reactor. In all cases, the functionality of the Pt//Ag/AgCl system was similar to that of a conventional Ag/AgCl reference electrode. Variations in the electrolyte did not alter the potential or voltammetric profile recorded when using the pseudoreference system, although peak currents were generally improved and potential values shifted by approximately +350 mV in comparison with the Ag/AgCl electrode, therefore, the system pseudoreference can be applied in any electrochemical system due to the constant potential difference. It is concluded that the pseudoreference electrode can be used with advantage to obtain potentiometric and amperometric measurements in both simple and complex electrochemical systems.
Resumo:
Cloud point extraction (CPE) was employed for separation and preconcentration prior to the determination of nickel by graphite furnace atomic absorption spectrometry (GFAAS), flame atomic absorption spectrometry (FAAS) or UV-Vis spectrophotometry. Di-2-pyridyl ketone salicyloylhydrazone (DPKSH) was used for the first time as a complexing agent in CPE. The nickel complex was extracted from the aqueous phase using the Triton X-114 surfactant. Under optimized conditions, limits of detection obtained with GFAAS, FAAS and UV-Vis spectrophotometry were 0.14, 0.76 and 1.5 mu g L-1, respectively. The extraction was quantitative and the enrichment factor was estimated to be 27. The method was applied to natural waters, hemodialysis concentrates, urine and honey samples. Accuracy was evaluated by analysis of the NIST 1643e Water standard reference material.
Spatial reference of black capuchin monkeys in Brazilian Atlantic Forest: egocentric or allocentric?
Resumo:
Wild primates occupy large home ranges and travel long distances to reach goals. However, how primates are able to remember goal locations and travel efficiently is unclear. Few studies present consistent results regarding what reference system primates use to navigate, and what kind of spatial information they recognize. We analysed the pattern of navigation of one wild group of black capuchin monkeys, Cebus nigritus, at Atlantic Forest for 100 days in Carlos Botelho State Park (PECB), Brazil. We tested predictions based on the alternative hypotheses that black capuchin monkeys navigate using a sequence of landmarks as an egocentric reference system or an allocentric reference system, or both, depending on availability of food resources. The group location was recorded using a GPS device collecting coordinates at 5 min intervals, and route maps were generated using ArcView v9.3.1. The study group travelled through habitual routes during less than 30% of our study sample, and revisited resources from different starting points, using different paths and routes, even when prominent landmarks near feeding locations were not visible. The study group used habitual routes more frequently when high-quality foods were scarce, and navigated using different paths when revisiting food sources. Results support the hypothesis that black capuchin monkeys at PECB navigate using both egocentric and allocentric systems of reference, depending on the quality and distribution of the food resource they find. (C) 2010 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.
Resumo:
Most atypical antipsychotic drugs (APDs), e. g. risperidone (RIS), produce more extensive blockade of brain serotonin (5-HT)(2A) than dopamine (DA) D-2 receptors. This distinguishes them from typical APDs, e.g. haloperidol (HAL). Our objective was to test the hypothesis that augmentation of low doses of RIS or HAL (2 mg/day) with pimavanserin (PIM), a selective 5-HT2A inverse agonist, to enhance 5-HT2A receptor blockade, can achieve efficacy comparable to RIS, 6 mg/day, but with lesser side effects. In a multi-center, randomized, double-blind, 6 week trial, 423 patients with chronic schizophrenia experiencing a recent exacerbation of psychotic symptoms were randomized to RIS2mg + placebo (RIS2PBO), RIS2mg + PIM20mg (RIS2PIM), RIS6mg + PBO (RIS6PBO), HAL2mg + PBO (HAL2PBO), or HAL2mg + PIM20mg (HAL2PIM). Improvement in psychopathology was measured by the PANSS and CGI-S. The reduction in PANSS Total Score with RIS2PIM at endpoint was significantly greater than RIS2PBO: -23.0 vs. -16.3 (p = 0.007), and not significantly different from the RIS6PBO group: -23.2 points. The percentage of patients with >= 20% improvement at day 15 in the RIS2PIM group was 62.3%, significantly greater than the RIS6PBO (42.1%; p = 0.01) and the RIS2PBO groups (37.7%; p = 0.002). Weight gain and hyperprolactinemia were greater in the RIS6PBO group than the RIS2PIM group but there was no difference in extrapyramidal side effects (EPS). HAL2PBO and HAL2PIM were not significantly different from each other in efficacy but HAL2PIM had less EPS at end point. Both HAL groups and RIS6PBO showed equal improvement in psychopathology at endpoint, indicating HAL 2 mg/day is effective to treat an acute exacerbation in chronic schizophrenia patients. In conclusion, a sub-effective RIS dose combined with PIM to enhance 5-HT2A receptor blockade provided faster onset of action, and at endpoint, equal efficacy and better safety, compared to standard dose RIS. These results support the conclusion that 5-HT2A receptor blockade is a key component of the action of some atypical APDs and can reduce EPS due to a typical APD. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Abstract Background Spotted cDNA microarrays generally employ co-hybridization of fluorescently-labeled RNA targets to produce gene expression ratios for subsequent analysis. Direct comparison of two RNA samples in the same microarray provides the highest level of accuracy; however, due to the number of combinatorial pair-wise comparisons, the direct method is impractical for studies including large number of individual samples (e.g., tumor classification studies). For such studies, indirect comparisons using a common reference standard have been the preferred method. Here we evaluated the precision and accuracy of reconstructed ratios from three indirect methods relative to ratios obtained from direct hybridizations, herein considered as the gold-standard. Results We performed hybridizations using a fixed amount of Cy3-labeled reference oligonucleotide (RefOligo) against distinct Cy5-labeled targets from prostate, breast and kidney tumor samples. Reconstructed ratios between all tissue pairs were derived from ratios between each tissue sample and RefOligo. Reconstructed ratios were compared to (i) ratios obtained in parallel from direct pair-wise hybridizations of tissue samples, and to (ii) reconstructed ratios derived from hybridization of each tissue against a reference RNA pool (RefPool). To evaluate the effect of the external references, reconstructed ratios were also calculated directly from intensity values of single-channel (One-Color) measurements derived from tissue sample data collected in the RefOligo experiments. We show that the average coefficient of variation of ratios between intra- and inter-slide replicates derived from RefOligo, RefPool and One-Color were similar and 2 to 4-fold higher than ratios obtained in direct hybridizations. Correlation coefficients calculated for all three tissue comparisons were also similar. In addition, the performance of all indirect methods in terms of their robustness to identify genes deemed as differentially expressed based on direct hybridizations, as well as false-positive and false-negative rates, were found to be comparable. Conclusion RefOligo produces ratios as precise and accurate as ratios reconstructed from a RNA pool, thus representing a reliable alternative in reference-based hybridization experiments. In addition, One-Color measurements alone can reconstruct expression ratios without loss in precision or accuracy. We conclude that both methods are adequate options in large-scale projects where the amount of a common reference RNA pool is usually restrictive.
Resumo:
Industrial recurrent event data where an event of interest can be observed more than once in a single sample unit are presented in several areas, such as engineering, manufacturing and industrial reliability. Such type of data provide information about the number of events, time to their occurrence and also their costs. Nelson (1995) presents a methodology to obtain asymptotic confidence intervals for the cost and the number of cumulative recurrent events. Although this is a standard procedure, it can not perform well in some situations, in particular when the sample size available is small. In this context, computer-intensive methods such as bootstrap can be used to construct confidence intervals. In this paper, we propose a technique based on the bootstrap method to have interval estimates for the cost and the number of cumulative events. One of the advantages of the proposed methodology is the possibility for its application in several areas and its easy computational implementation. In addition, it can be a better alternative than asymptotic-based methods to calculate confidence intervals, according to some Monte Carlo simulations. An example from the engineering area illustrates the methodology.