7 resultados para treatment planning

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4704496]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hadron therapy is a promising technique to treat deep-seated tumors. For an accurate treatment planning, the energy deposition in the soft and hard human tissue must be well known. Water has been usually employed as a phantom of soft tissues, but other biomaterials, such as hydroxyapatite (HAp), used as bone substitute, are also relevant as a phantom for hard tissues. The stopping power of HAp for H+ and He+ beams has been studied experimentally and theoretically. The measurements have been done using the Rutherford backscattering technique in an energy range of 450-2000 keV for H+ and of 400-5000 keV for He+ projectiles. The theoretical calculations are based in the dielectric formulation together with the MELF-GOS (Mermin Energy-Loss Function – Generalized Oscillator Strengths) method [1] to describe the target excitation spectrum. A quite good agreement between the experimental data and the theoretical results has been found. The depth dose profile of H+ and He+ ion beams in HAp has been simulated by the SEICS (Simulation of Energetic Ions and Clusters through Solids) code [2], which incorporates the electronic stopping force due to the energy loss by collisions with the target electrons, including fluctuations due to the energy-loss straggling, the multiple elastic scattering with the target nuclei, with their corresponding nuclear energy loss, and the dynamical charge-exchange processes in the projectile charge state. The energy deposition by H+ and He+ as a function of the depth are compared, at several projectile energies, for HAp and liquid water, showing important differences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The objective of this study was to compare the estimated cost of clinical and surgical treatment for basl cell carcinoma of the eyelid. Methods: This was a pilot study of 12 patients with basal cell carcinoma receiving treatment with 5% imiquimod cream at the ocular plastic surgery center, medical school University of Sao Paulo (HC-FMUSP, Brazil). The cost of clinical treatment was estimated based on the time of treatment and amount of medication consumed by patients in the home setting. The cost of surgical treatment was estimated by ophthalmologists with experience in reconstructive plastic surgery based on analysis of images of the same patients. Surgeons responded to a questionnaire with four questions about surgical technique, surgical materials required, estimated duration of surgery and type of anesthesia. Results: Immunotherapy lasted from 8 to 12 weeks. All patients reported each cold-stored sachet with 5% imiquimod cream lasted 3 days. According to the institution, a box with 12 sachets costs BRL 480.00. Patients required 1.58-3.11 boxes for complete treatment, corresponding to a total cost of BRL 758.40-1,492.80. Based on image analysis, surgeons evaluated surgery would require 1-3 hours. The estimated cost of surgery room and staff was BRL 263.00, to which the cost of supplies was added. Thus, the total cost of surgical treatment was BRL 272.61-864.82. On the average, immunotherapy was 57,64% more costly than surgical treatment. Conclusions: Malignant eyelid tumors are a common finding in clinical ophthalmology. Surgery is still the treatment of choice at our institution, but immunotherapy with 5% imiquimod cream may be indicated for patients with multiple lesions or high surgical risk and for patients declining surgery for reasons of fear or esthetic concerns. The ability to estimate costs related to the treatment of malignant eyelid tumors is an important aid in the financial planning of health care institutions. Further studies should evaluate the possibility of institutions equating the cost of immunotherapy and surgical treatment by acquiring similar but less expensive medications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To use published literature and experts' opinion to investigate the clinical meaning and magnitude of changes in the Quality of Life (QOL) of groups of patients measured with the European Organisation for the Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30). Methods: An innovative method combining systematic review of published studies, expert opinions and meta-analysis was used to estimate large, medium, and small mean changes over time for QLQ-C30 scores. Results: Nine hundred and eleven papers were identified, leading to 118 relevant papers. One thousand two hundred and thirty two mean changes in QOL over time were combined in the meta-analysis, with timescales ranging from four days to five years. Guidelines were produced for trivial, small, and medium size classes, for each subscale and for improving and declining scores separately. Estimates for improvements were smaller than respective estimates for declines. Conclusions: These guidelines can be used to aid sample size calculations and interpretation of mean changes over time from groups of patients. Observed mean changes in the QLQ-C30 scores are generally small in most clinical situations, possibly due to response shift. Careful consideration is needed when planning studies where QOL changes over time are of primary interest; the timing of follow up, sample attrition, direction of QOL changes, and subscales of primary interest are key considerations. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min(-1) for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H2O2 concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Apical root resorption is a frequent and occasionally critical problem in orthodontic patients undergoing induced tooth movement. One of the factors that might influence prognosis, especially in maxillary incisors, which most frequently present resorptions, are the so-called the anatomical barriers; that is, proximity of the buccal and palatal cortical bones to the maxillary incisor roots. OBJECTIVE: The purpose of this research was to investigate whether patients with excessive vertical growth really present a small distance between the alveolar cortical bones and the maxillary incisor roots, and whether there is a correlation between this distance and the root resorption index in comparison with patients presenting horizontal growth. METHODS: The sample comprised orthodontic records of 18 patients with extraction planning of first maxillary premolars and treatment by the standard and/or preadjusted edgewise brackets. Their initial and final periapical radiographs were evaluated to determine the amount of root resorption that occurred. RESULTS: On the palatal side, patients with excessive vertical growth (Group 2 - SN-GoGn > 43º) showed a narrower alveolar bone than the horizontal growth patients (Group 1 - SN-GoGn < 29º). However, the distance between the buccal cortical bone and the central incisor root apex showed no significant difference between Groups 1 and 2; CONCLUSIONS: It was concluded that there are no correlations between the proximity of buccal cortical bone, maxillary incisor roots and the root resorption index.