5 resultados para public opinion on biometric devices

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the impact of global and/or local strain engineering techniques on tri-gate p- and nMuGFETs performance is experimentally evaluated. Multiple gate structures were analyzed through basic and analog performance parameters for four different splits processed with different strain-engineering techniques (unstrained, uniaxial, biaxial and uniaxial+biaxial stress). While n-channel devices with narrow fins present a worse analog behavior, biaxial stress promotes the electron mobility for larger devices increasing the voltage gain. Besides the voltage gain, the transconductance, output conductance and Early Voltage are also evaluated. Although pMuGFETs are less affected by the strain engineering, they present better analog behavior for all studied devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A política para Jürgen Habermas se faz com a formação de consciências e com o investimento na linguagem, no falar cotidiano, na relação intersubjetiva. Já para Niklas Luhmann, a política se faz por si mesma, e a opinião pública não tem relação com a opinião pessoal. Não adianta investir na linguagem, porque ela é pré-social, está além dos sujeitos, nenhuma democratização pode sair daí. Mas as propostas dos dois pensadores mostram-se insuficientes para a atualidade, com suas altas tecnologias comunicacionais, pois nenhum dos modelos dá uma resposta animadora para a questão das redes, nenhuma delas visualiza um espaço mediático próprio fazendo a mediação dos sistemas, nenhuma delas dá elementos para a construção de uma teoria da comunicação tecnologicamente avançada.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Bayesian nonparametric model for Taguchi's on-line quality monitoring procedure for attributes is introduced. The proposed model may accommodate the original single shift setting to the more realistic situation of gradual quality deterioration and allows the incorporation of an expert's opinion on the production process. Based on the number of inspections to be carried out until a defective item is found, the Bayesian operation for the distribution function that represents the increasing sequence of defective fractions during a cycle considering a mixture of Dirichlet processes as prior distribution is performed. Bayes estimates for relevant quantities are also obtained. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One-transistor floating-body random access memory retention time distribution is investigated on silicon-on-insulator UTBOX devices. It is shown that the average retention time can be improved by two to three orders of magnitude by reducing the body-junction electric field. However, the retention time distribution, which is mainly caused by the generation-recombination center density variation, remains similar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The opinion on the 'straight-wire' concept has been evolving since its origin, characterized by faithful followers or absolute skepticism. Currently, it seems reasonable to state that most professionals have a more realistic and critical viewpoint, with an attitude that reveals Orthodontics' maturity and greater knowledge on the technique. The most relevant criticisms refer to the impossibility of the both the Straight-Wire and the Standard systems to completely express the characteristics related to the brackets due to mechanical deficiencies, such as bracket/wire play. OBJECTIVES: A critical analysis of this relationship, which is unclear due to lack of studies, was the scope of this paper. METHODS: The compensatory treatment of two patients, using Capelozza's individualized brackets, works as the scenery for cephalometric evaluation of changes in incisor inclination produced by different dimensions of leveling archwires. RESULTS: The evaluation of these cases showed that, while the introduction of a 0.019 x 0.025-in stainless steel archwire in a 0.022 x 0.030-in slot did not produce significant changes in incisor inclination, the 0.021 x 0.025-in archwire was capable of changing it, mainly in mandibular incisors, and in the opposite direction to the compensation. CONCLUSION: Considering compensatory treatments, even when using an individualized prescription according to the malocclusion, the bracket/wire play seems to be a positive factor for malocclusion correction, without undesirable movements. Therefore, it seems reasonable to admit that, until a bracket system can have absolute individualization, the use of rectangular wires that still have a certain play with the bracket slot is advisable.