39 resultados para post hoc hypotheses

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This in vitro study compared different ultrasonic vibration modes for intraradicular cast post removal. The crowns of 24 maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the canals were treated endodontically. The post holes were prepared and root canal impressions were taken with self-cured resin acrylic. After casting, the posts were cemented with zinc phosphate cement. The samples were randomly distributed into 3 groups (n=8): G1: no ultrasonic vibration (control); G2: tip of the ultrasonic device positioned perpendicularly to core surface and close to the incisal edge; and G3: tip of the ultrasonic device positioned perpendicularly to core surface at cervical region, close to the line of cementation. An Enac OE-5 ultrasound unit with an ST-09 tip was used. All samples were submitted to the tensile test using an universal testing machine at a crosshead speed of 1 mm/min. Data were subjected to one-way ANOVA and Tukey's post-hoc tests (α=0.05). Mean values of the load to dislodge the posts (MPa) were: G1 = 4.6 (± 1.4) A; G2 = 2.8 (± 0.9) B, and G3= 0.9 (± 0.3) C. Therefore, the ultrasonic vibration applied with the tip of device close to the core's cervical area showed higher ability to reduce the retention of cast post to root canal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Based on evidence showing that electrical stimulation of the nervous system is an effective method to decrease chronic neurogenic pain, we aimed to investigate whether the combination of 2 methods of electrical stimulation-a method of peripheral stimulation [transcutaneous electrical nerve stimulation (TENS)] and a method of noninvasive brain stimulation (transcranial direct current stimulation (tDCS)]-induces greater pain reduction as compared with tDCS alone and sham stimulation. Methods: We performed a preliminary, randomized, sham-controlled, crossover, clinical study in which 8 patients were randomized to receive active tDCS/active TENS (""tDCS/TENS"" group), active tDCS/sham TENS (""tDCS"" group), and sham tDCS/sham TENS (""sham"" group) stimulation. Assessments were performed immediately before and after each condition by a blinded rater. Results: The results showed that there was a significant difference in pain reduction across the conditions Of stimulation (P = 0.006). Post hoc tests showed significant pain reduction as compared with baseline after the tDCS/TENS condition [reduction by 36.5% (+/- 10.7), P = 0.004] and the tDCS condition [reduction by 15.5% (+/- 4.9), P = 0.014], but not after sham stimulation (P = 0.35). In addition, tDCS/TENS induced greater pain reduction than tDCS (P = 0.02). Conclusions: The results of this pilot study suggest that the combination of TENS with tDCS has a superior effect compared with tDCS alone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Highly active antiretroviral therapy for AIDS is known to increase cardiovascular risk, but the effects of potent antiretroviral agents according to gender are unknown. Objective: The present study evaluated the impact of HIV infection treatment on aortic stiffness according to gender. Methods: From university-affiliated hospitals, we recruited 28 AIDS patients undergoing highly active antiretroviral treatment (HAART), 28 treatment-naive HIV-infected patients, 44 patients with type 2 diabetes, and 30 controls. Aortic stiffness was determined by measuring pulse wave velocity (PWV) using a validated and non-invasive automatic device. Results: The crude mean PWV values and 95% confidence intervals (95% CI) for HAART, diabetics, and controls were 9.77 m/s (95% CI 9.17-10.36),, 9.00 m/s (95% CI 8.37-9.63), 9.90 m/s (95% CI 9.32-10.49), and 9.28 m/s (95% CI 8.61-9.95), respectively, for men (P-value for trend = 0.14), and 9.61 m/s (95% CI 8.56-10.66), 8.45 m/s (95% CI 7.51-9.39), 9.83 (95% CI 9.21-10.44), and 7.79 m/s (95% CI 6.99-8.58), respectively, for women (P-value for trend <0.001). Post-hoc analysis revealed a significant difference between the mean PWV values in the HAART group and controls in women (P-value <0.01). After adjusting for other potential covariates, including systolic blood pressure and diabetes, these results did not change. The findings indicate that the impact of HAART treatment on aortic stiffness was amplified in women with hypertension, dyslipidemia, and metabolic syndrome. Conclusion: Potent anti-retroviral agents used in the treatment of HIV infection increases aortic stiffness, mainly among women with higher cardiovascular risk. (Arq Bras Cardiol 2012;99(6):1100-1107)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate micronucleus (MN) frequency in polychromatic erythrocytes (PCE) of female rats in persistent estrus (a model developed to mimic polycystic ovary syndrome) treated with selective estrogen receptor modulators (SERMs, tamoxifen, and raloxifene). Forty female Wistar-Hannover rats were divided into four groups of 10 animals each: Group I (normally cycling rats) and Group II (persistent estrus) both received only vehicle, while Group III (persistent estrus) was treated with tamoxifen (250 mu g/animal/day) and Group IV (persistent estrus) was treated with raloxifene (750 mu g/animal/day). Tamoxifen and raloxifene were given by oral gavage beginning on postnatal day 90 and continuing for 30 consecutive days. Peripheral blood samples were collected from tails 1 day following the last exposure. Blood smears were made on glass slides and stained with 10% Giemsa solution. ANOVA and a Tukey post-hoc test were used for data analysis. Mean percentages of MN were 1.82 +/- 0.13, 5.20 +/- 0.24, 3.32 +/- 0.13, and 3.04 +/- 0.12 in Groups I, II, III, and IV, respectively. The results indicate that tamoxifen and raloxifene similarly reduced the formation of MNPCE of female rats in persistent estrus (P < 0.0001 for Groups III and IV vs. Group II), using the dosages and time periods applied in the present study. The data suggest possibly antimutagenic effects of SERMs under high levels of estrogens. The findings also suggest that this is an interesting animal model for studying the genotoxicity of estrogens. Environ. Mol. Mutagen. 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Polycystic ovary syndrome (PCOS) is an endocrine disorder associated with metabolic dysfunction and changes in cardiovascular risk markers, and using oral contraceptives (OCs) may exert a further negative effect on these alterations in patients with PCOS. Thus, the primary objective of this study was to assess the effects on arterial function and structure of an OC containing chlormadinone acetate (2 mg) and ethinylestradiol (30 mcg), alone or combined with spironolactone (OC+SPL), in patients with PCOS. Study Design: This was a randomized, controlled clinical trial. Fifty women with PCOS between 18 and 35 years of age were randomized by a computer program to use OC or OC+SPL. Brachial artery flow-mediated vasodilation, carotid intima-media thickness and the carotid artery stiffness index were evaluated at baseline and after 6 and 12 months. Serum markers for cardiovascular disease were also analyzed. The intragroup data were analyzed using analysis of variance with Tukey's post hoc test. A multivariate linear regression model was used to analyze the intergroup data. Results: At 12 months, the increase in mean total cholesterol levels was greater in the OC+SPL group than in the OC group (27% vs. 13%, respectively; p=.02). The increase in mean sex hormone-binding globulin levels was greater in the OC group than in the OC+SPL group (424% vs. 364%, respectively; p=.01). No statistically significant differences between the groups were found for any of the other variables. Conclusion: The addition of spironolactone to an OC containing chlormadinone acetate and ethinylestradiol conferred no cardiovascular risk-marker advantages in young women with PCOS. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This in vitro study evaluated the bond strength of adhesive restorative materials to sound and eroded dentin. Thirty-six bovine incisors were embedded in acrylic resin and ground to obtain flat buccal dentin surfaces. Specimens were randomly allocated in 2 groups: sound dentin (immersion in artificial saliva) and eroded dentin (pH cycling model - 3x / cola drink for 7 days). Specimens were then reassigned according to restorative material: glass ionomer cement (Ketac (TM) Molar Easy Mix), resin-modified glass ionomer cement (Vitremer (TM)) or adhesive system with resin composite (Adper Single Bond 2 + Filtek Z250). Polyethylene tubes with an internal diameter of 0.76 mm were placed over the dentin and filled with the material. The microshear bond test was performed after 24 h of water storage at 37 degrees C. The failure mode was evaluated using a stereomicroscope (400x). Bond strength data were analyzed with two-way ANOVA and Tukey's post hoc tests (alpha = 0.05). Eroded dentin showed bond strength values similar to those for sound dentin for all materials. The adhesive system showed the highest bond strength values, regardless of the substrate (p < 0.0001). For all groups, the adhesive/mixed failure prevailed. In conclusion, adhesive materials may be used in eroded dentin without jeopardizing the bonding quality. It is preferable to use an etch-and-rinse adhesive system because it shows the highest bond strength values compared with the glass ionomer cements tested.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the nutritional status of patients in the late postoperative period of pancreaticoduodenectomy (PD) and compare the long-term outcome according to pylorus-preserving (PPPD) or the standard technique (SPD) in which the pylorus is resected. METHODS: This prospective study was conducted twelve months prior or more in patients who had underwent PD (PD Group, n=15) and health volunteers (Control Group, n=15). At a post hoc analysis, the PD Group was divided in PPPD Subgroup (n=9) and SPD Subgroup (n=6), according to the PD techniques. Gastrointestinal complaints and nutritional status were evaluated, apart from a biochemical assessment; Student t-test or Mann-Whitney test were used. RESULTS: The patients recovered their body weight and the gastrointestinal complaints were uncommon. The PD Group showed higher energy and protein intake even though BMI was lower than in Control Group. There were no differences in laboratorial data, except for higher glycemia, serum alkaline phosfatase and C-reactive protein in PD Group. There was no difference in the various parameters evaluated when the Subgroups (PPPD and SPD) were compared. CONCLUSION: For long-term pancreaticoduodenectomy, the gastrointestinal symptoms are minimal and the patients had the clinical and nutritional status preserved, regardless of pylorus preservation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the erosive potential of different types (concentrated and powdered) and commercial brands of industrialised grape juices. The pH of all five fruit drinks was measured at two time points: immediately after preparation and 24 hours later. Sixty specimens of bovine enamel were randomly allocated and immersed in different types of grape juice (n = 10) for 10 minutes four times a day for fifteen days. The enamel alteration was analysed using surface Knoop microhardness (KHN) and surface roughness (R-a) tests at baseline and on the 5th, 10th and 15th days of the experiment. Two way ANOVA, Tukey's post hoc and Pearson's correlation tests were used for statistical analysis (alpha = 5%). The grape juices presented pH values ranging from 2.9 to 3.5. All of the tested juices promoted significant enamel mineral loss (p < 0.05) on the first evaluation (5th day of immersion) and produced a significant increase in the mean roughness from the 10th day on when compared to the control group (p < 0.05). By the 15th day, all of the beverages had produced surface roughnesses that were significantly higher than that of the control group. The results suggest that all grape juices, regardless of their commercial presentation, present erosive potential.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague-Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by similar to 20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100 (R), 3M-ESPE and Panavia F 2.0 (R), Kuraray) used for cementing fiber-reinforced resin posts (Fibrekor (R) - Jeneric Pentron) under three different curing protocols and two water storage times. Material and methods: Sixty 16mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: a) no light activation; b) light-activation immediately after seating the post, and; c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. Results: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. Conclusions: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous (TM) endothelial progenitor cell capturing R stent (TM) placement in patients from the e-HEALING registry. Background: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. Methods: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. Results: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.651.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.551.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. Conclusions: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding. (C) 2011 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: This study evaluated the degree of conversion (DC) and working time (WT) of two commercial, dual-cured resin cements polymerized at varying temperatures and under different curing-light accessible conditions, using Fourier transformed infrared analysis (FTIR). Materials and Methods: Calibra (Cal; Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were tested at 25 degrees C or preheated to 37 degrees C or 50 degrees C and applied to a similar-temperature surface of a horizontal attenuated-total-reflectance unit (ATR) attached to an infrared spectrometer. The products were polymerized using one of four conditions: direct light exposure only (600 mW/cm(2)) through a glass slide or through a 1.5- or 3.0-mm-thick ceramic disc (A2 shade, IPS e.max, Ivoclar Vivadent) or allowed to self-cure in the absence of light curing. FTIR spectra were recorded for 20 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm(-1)) immediately after application to the ATR. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios precuring and 20-min postcuring as well as during each 1-second interval. Time-based monomer conversion analysis was used to determine WT at each temperature. DC and WT data (n=6) were analyzed by two-way analysis of variance and Tukey post hoc test (p=0.05). Results: Higher temperatures increased DC regardless of curing mode and product. For Calibra, only the 3-mm-thick ceramic group showed lower DC than the other groups at 25 degrees C (p=0.01830), while no significant difference was observed among groups at 37 degrees C and 50 degrees C. For Variolink, the 3-mm-thick ceramic group showed lower DC than the 1-mm-thick group only at 25 degrees C, while the self-cure group showed lower DC than the others at all temperatures (p=0.00001). WT decreased with increasing temperature: at 37 degrees C near 70% reduction and at 50 degrees C near 90% for both products, with WT reduction reaching clinically inappropriate times in some cases (p=0.00001). Conclusion: Elevated temperature during polymerization of dual-cured cements increased DC. WT was reduced with elevated temperature, but the extent of reduction might not be clinically acceptable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate (1) the influence of complete denture quality and years of denture use on masticatory efficiency and (2) the relationship between complete denture quality and years of use. Materials and Methods: A cross-sectional study was conducted with 93 edentulous patients (mean age: 65.6 years) wearing both mandibular and maxillary dentures. Patients were classified into two categories according to years of denture use: <= 2 years and >= 5 years. Masticatory efficiency was evaluated via the colorimetric method with beads as the artificial test food. A reproducible method for objective evaluation of the technical quality of complete dentures was employed. The association between denture quality and years of denture use was analyzed using chi-square and Fisher exact tests. The results of masticatory efficiency testing were analyzed using two-way analysis of variance (with the Tukey post hoc test) in terms of years of denture use <= 2 years, >= 5 years) and denture quality (poor, average, good). Results: A significant relationship was found between denture quality and years of denture use (P < .05). Masticatory efficiency differed significantly (P < .05) between patients with <= 2 years of denture use (0.101 +/- 0.076 absorbance) and >= 5 years of use (0.068 +/- 0.076 absorbance). Masticatory efficiency was not influenced by denture quality. Conclusions: Complete denture quality and masticatory efficiency significantly decreased over time. However, complete denture quality did not influence masticatory efficiency. Int J Prosthodont 2012;25:625-630.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Describe the total energy value and percentage contribution of calories from macronutrients in the diet of elderly individuals living in Fortaleza/CE. Methods: This is a population-based, cross-sectional domiciliary study, which included 458 elderly individuals (66.6% women). The variables evaluated were total energy value (TEV) and the percentage contribution of calories from proteins, carbohydrates, and lipids. The results are shown as mean, standard deviation, and percentile distribution (P5, P10, P25, P50, P75, P90, P95). The Student's t-test and analysis of variance (one-way ANOVA) with LSD post-hoc tests were used to determine the statistical significance of means between two groups and among three or more groups, respectively. Results: When comparing the mean values of TEV among categories of socioeconomic and demographic variables, statistically significant differences were found between women for ethnicity, years of schooling and socioeconomic level. Among men, differences were found for years of schooling and socioeconomic level. The mean energy value of men's diet was significantly higher than that of women (1475.8 kcal and 1236.4 kcal, respectively). The mean values of calorie percentage contribution from proteins, carbohydrates, and lipids were similar between men and women. Conclusion: The elderly of this study showed significant differences in mean values of TEV between sexes and between the categories years of schooling and socioeconomic level. Women also showed significant differences between the ethnic categories. The mean relative contribution of macronutrients in TEV was similar between genders and age groups.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Bipolar disorder (BD) is a highly incapacitating disease typically associated with high rates of familial dysfunction. Despite recent literature suggesting that maternal care is an important environmental factor in the development of behavioral disorders, it is unclear how much maternal care is dysfunctional in BD subjects. Objective: The objective of this study was to characterize maternal care in DSM-IV/SCID diagnosed BD type I subjects compared to healthy controls with (PD) and without (NPD) other psychiatric diagnoses. Materials and methods: Thirty-four BD mothers and 106 controls underwent an interview about family planning and maternal care, obstetrical complications, and mother-child interactions. K-SADS-PL questions about violence exposure were used to ascertain domestic violence and physical/sexual abuse. Results: BD mothers were less likely to have stable unions (45.5%; p < 0.01) or to live with the biological father of their children (33.3%; p < 0.01), but had higher educational level and higher rates of social security use/retirement. They also had fewer children and used less contraceptive methods than controls. Children of BD women had higher rates of neonatal anoxia, and reported more physical abuse (16.1%; p = 0.02) than offspring of NPD mothers. Due to BD mothers' symptoms, 33.3% of offspring suffered physical and/or psychological abuse. Limitations: Post hoc analysis, and the use of questions as a surrogate of symptoms as opposed to validated instruments. Conclusion: This is one of few reports confirming that maternal care given by BD women is dysfunctional. BD psychopathology can lead to poor maternal care and both should be considered important environmental risk factors in BD, suggesting that BD psychoeducation should include maternal care orientation. (C) 2012 Elsevier B.V. All rights reserved.