12 resultados para methods : laboratory

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Background Direct smear examination with Ziehl-Neelsen (ZN) staining for the diagnosis of pulmonary tuberculosis (PTB) is cheap and easy to use, but its low sensitivity is a major drawback, particularly in HIV seropositive patients. As such, new tools for laboratory diagnosis are urgently needed to improve the case detection rate, especially in regions with a high prevalence of TB and HIV. Objective To evaluate the performance of two in house PCR (Polymerase Chain Reaction): PCR dot-blot methodology (PCR dot-blot) and PCR agarose gel electrophoresis (PCR-AG) for the diagnosis of Pulmonary Tuberculosis (PTB) in HIV seropositive and HIV seronegative patients. Methods A prospective study was conducted (from May 2003 to May 2004) in a TB/HIV reference hospital. Sputum specimens from 277 PTB suspects were tested by Acid Fast Bacilli (AFB) smear, Culture and in house PCR assays (PCR dot-blot and PCR-AG) and their performances evaluated. Positive cultures combined with the definition of clinical pulmonary TB were employed as the gold standard. Results The overall prevalence of PTB was 46% (128/277); in HIV+, prevalence was 54.0% (40/74). The sensitivity and specificity of PCR dot-blot were 74% (CI 95%; 66.1%-81.2%) and 85% (CI 95%; 78.8%-90.3%); and of PCR-AG were 43% (CI 95%; 34.5%-51.6%) and 76% (CI 95%; 69.2%-82.8%), respectively. For HIV seropositive and HIV seronegative samples, sensitivities of PCR dot-blot (72% vs 75%; p = 0.46) and PCR-AG (42% vs 43%; p = 0.54) were similar. Among HIV seronegative patients and PTB suspects, ROC analysis presented the following values for the AFB smear (0.837), Culture (0.926), PCR dot-blot (0.801) and PCR-AG (0.599). In HIV seropositive patients, these area values were (0.713), (0.900), (0.789) and (0.595), respectively. Conclusion Results of this study demonstrate that the in house PCR dot blot may be an improvement for ruling out PTB diagnosis in PTB suspects assisted at hospitals with a high prevalence of TB/HIV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (â^ž), NLR (0.017), and Ef (99%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency`s technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To describe clinical and laboratory characteristics in patients with tuberculosis-related or lymphoma-related lymphocytic pleural effusions, in order to identify the variables that might contribute to differentiating between these diseases. Methods: This was a retrospective study involving 159 adult HIV-negative patients with tuberculosis-related or lymphoma-related lymphocytic effusions (130 and 29 patients, respectively), treated between October of 2008 and March of 2010 at the Pleural Diseases Outpatient Clinic of the University of Sao Paulo School of Medicine Hospital das Clinicas Heart Institute, in the city of Sao Paulo, Brazil. Results: Mean age and the mean duration of symptoms were lower in the tuberculosis group than in the lymphoma group. The levels of proteins, albumin, cholesterol, amylase, and adenosine deaminase (ADA) in pleural fluid, as well as the serum levels of proteins, albumin, and amylase, were higher in the tuberculosis group, whereas serum cholesterol and triglycerides were higher in the lymphoma group. Pleural fluid leukocyte and lymphocyte counts were higher in the tuberculosis group. Of the tuberculosis group patients, none showed malignant cells; however, 4 showed atypical lymphocytes. Among the lymphoma group patients, cytology for neoplastic cells was positive, suspicious, and negative in 51.8%, 24.1%, and 24.1%, respectively. Immunophenotyping of pleural fluid was conclusive in most of the lymphoma patients. Conclusions: Our results demonstrate clinical and laboratory similarities among the patients with tuberculosis or lymphoma. Although protein and ADA levels in pleural fluid tended to be higher in the tuberculosis group than in the lymphoma group, even these variables showed an overlap. However, none of the tuberculosis group patients had pleural fluid ADA levels below the 40-U/L cut-off point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cypermethrin dust was evaluated as a tool for the integrated management of lesser mealwonns (also called the darkling beetle), Alphitobius diaperinus (Panzer). This experiment examined the efficacy of the cypermethrin against adult and late instar lesser mealwonns under laboratory conditions. Two bioassay methods were evaluated, using either a petri plate or a covered plastic container simulating poultry house conditions. In the simulated conditions, two different samples were used and cypermethrin was either dusted onto the surface of the container or was directly dusted onto the bottom. The LC50 for adults was 636.6 ppm, however, 929.7 ppm of cypermethrin dust was needed to achieve a 50% mortality rate in late instar larvae 24 h after the administration of the insecticide. A similar trend was observed in the simulated poultry houses when the adult mortality was > 90% while effectiveness in late in. star larvae was decreased, i.e., between 50 and 85%. Significant differences in the toxicity profiles were observed in larvae mortality when cypermethrin it was dusted directly onto the litter surface, compared to the bottom of the container. We have verified that cypermethrin dust is available for use in poultry houses however, toxicity profiles of lesser mealworm may depend on the beetle's stage of development and method of application

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Although the release of cardiac biomarkers after percutaneous (PCI) or surgical revascularization (CABG) is common, its prognostic significance is not known. Questions remain about the mechanisms and degree of correlation between the release, the volume of myocardial tissue loss, and the long-term significance. Delayed-enhancement of cardiac magnetic resonance (CMR) consistently quantifies areas of irreversible myocardial injury. To investigate the quantitative relationship between irreversible injury and cardiac biomarkers, we will evaluate the extent of irreversible injury in patients undergoing PCI and CABG and relate it to postprocedural modifications in cardiac biomarkers and long-term prognosis. Methods/Design: The study will include 150 patients with multivessel coronary artery disease (CAD) with left ventricle ejection fraction (LVEF) and a formal indication for CABG; 50 patients will undergo CABG with cardiopulmonary bypass (CPB); 50 patients with the same arterial and ventricular condition indicated for myocardial revascularization will undergo CABG without CPB; and another 50 patients with CAD and preserved ventricular function will undergo PCI using stents. All patients will undergo CMR before and after surgery or PCI. We will also evaluate the release of cardiac markers of necrosis immediately before and after each procedure. Primary outcome considered is overall death in a 5-year follow-up. Secondary outcomes are levels of CK-MB isoenzyme and I-Troponin in association with presence of myocardial fibrosis and systolic left ventricle dysfunction assessed by CMR. Discussion: The MASS-V Trial aims to establish reliable values for parameters of enzyme markers of myocardial necrosis in the absence of manifest myocardial infarction after mechanical interventions. The establishments of these indices have diagnostic value and clinical prognosis and therefore require relevant and different therapeutic measures. In daily practice, the inappropriate use of these necrosis markers has led to misdiagnosis and therefore wrong treatment. The appearance of a more sensitive tool such as CMR provides an unprecedented diagnostic accuracy of myocardial damage when correlated with necrosis enzyme markers. We aim to correlate laboratory data with imaging, thereby establishing more refined data on the presence or absence of irreversible myocardial injury after the procedure, either percutaneous or surgical, and this, with or without the use of cardiopulmonary bypass.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concept of Education for Sustainable Development, ESD, has been introduced in a period where chemistry education is undergoing a major change, both in emphasis and methods of teaching. Studying an everyday problem, with an important socio-economic impact in the laboratory is a part of this approach. Presently, the students in many countries go to school in vehicles that run, at least partially, on biofuels; it is high time to let them test these fuels. The use of renewable fuels is not new: since 1931 the gasoline sold in Brazil contains 20 to 25 vol-% of bioethanol; this composition is being continually monitored. With ESD in mind, we have employed a constructivist approach in an undergraduate course, where UV-vis spectroscopy has been employed for the determination of the composition of two fuel blends, namely, bioethanol/water, and bioethanol/gasoline. The activities started by giving a three-part quiz. The first and second ones introduced the students to historical and practical aspects of the theme (biofuels). In the third part, we asked them to develop a UV-vis experiment for the determination of the composition of fuel blends. They have tested two approaches: (i) use of a solvatochromic dye, followed by determination of fuel composition from plots of the empirical fuel polarity versus its composition; (ii) use of an ethanol-soluble dye, followed by determination of the blend composition from a Beer's law plot; the former proved to be much more convenient. Their evaluation of the experiment was highly positive, because of the relevance of the problem; the (constructivist) approach employed, and the bright colors that the solvatochromic dye acquire in these fuel blends. Thus ESD can be fruitfully employed in order to motivate the students; make the laboratory "fun", and teach them theory (solvation). The experiments reported here can also be given to undergraduate students whose major is not chemistry (engineering, pharmacy, biology, etc.). They are low-cost and safe to be introduced at high-school level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the reduction reaction of paraquat herbicide was used to obtain analytical signals using electrochemical techniques of differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry. Analytes were prepared with laboratory purified water and natural water samples (from Mogi-Guacu River, SP). The electrochemical techniques were applied to 1.0 mol L-1 Na2SO4 solutions, at pH 5.5, and containing different concentrations of paraquat, in the range of 1 to 10 mu mol L-1, using a gold ultramicroelectrode. 5 replicate experiments were conducted and in each the mean value for peak currents obtained -0.70 V vs. Ag/AgCl yielded excellent linear relationships with pesticide concentrations. The slope values for the calibration plots (method sensitivity) were 4.06 x 10(-3), 1.07 x 10(-2) and 2.95 x 10(-2) A mol(-1) L for purified water by differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry, respectively. For river water samples, the slope values were 2.60 x 10(-3), 1.06 x 10(-2) and 3.35 x 10(-2) A mol(-1) L, respectively, showing a small interference from the natural matrix components in paraquat determinations. The detection limits for paraquat determinations were calculated by two distinct methodologies, i.e., as proposed by IUPAC and a statistical method. The values obtained with multiple square waves voltammetry were 0.002 and 0.12 mu mol L-1, respectively, for pure water electrolytes. The detection limit from IUPAC recommendations, when inserted in the calibration curve equation, an analytical signal (oxidation current) is smaller than the one experimentally observed for the blank solution under the same experimental conditions. This is inconsistent with the definition of detection limit, thus the IUPAC methodology requires further discussion. The same conclusion can be drawn by the analyses of detection limits obtained with the other techniques studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate whether the presence of polycystic ovary syndrome (PCOS) alters multiple ultrasonographic and laboratory markers of metabolic and cardiovascular disease risk in obese women without any other health condition that could interfere with combined oral contraceptive (COC) eligibility criteria. Methods This was a case- control study evaluating 90 obese women ( body mass index ( BMI) = 30.0 kg/m2 and < 40 kg/m2) aged between 18 and 40 years without any other health condition that could interfere with COC eligibility criteria, of whom 45 had PCOS and 45 were age- matched controls. BMI, waist and hip circumference, arterial blood pressure, fasting insulin and glucose, quantitative insulin sensitivity check index ( QUICKI), highdensity lipoprotein cholesterol, low- density lipoprotein cholesterol, total cholesterol, triglycerides, testosterone, sex hormone- binding globulin, free androgen index ( FAI), carotid stiffness index, intima media thickness, flowmediated dilatation ( FMD) of the brachial artery and non- alcoholic fatty liver disease ( NAFLD) were assessed. Results In women with PCOS, we observed a higher frequency of NAFLD ( 73.3 vs. 46.7%, P < 0.01) and higher FAI ( 10.4 vs. 6.8%, P < 0.01). We also observed a trend towards increased insulin levels ( 10.06 +/- 6.66 vs. 7.45 +/- 5.88 mu IU/mL, P = 0.05), decreased QUICKI ( 0.36 +/- 0.06 vs. 0.39 +/- 0.07, P = 0.05) and decreased FMD ( 7.00 +/- 3.87 vs. 8.41 +/- 3.79%, P = 0.08). No other significant difference was observed. Conclusions NAFLD is frequent in obese women without any other health condition that could interfere with COC eligibility criteria, especially in those with PCOS. This should be considered when choosing the best contraceptive option. Copyright (C) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The biorhythm of serum uric acid was evaluated in a large sample of a clinical laboratory database by spectral analysis and the influence of the gender and age on uric acid variability. Methods: Serum uric acid values were extracted from a large database of a clinical laboratory from May 2000 to August 2006. Outlier values were excluded from the analysis and the remaining data (n = 73,925) were grouped by gender and age ranges. Rhythm components were obtained by the Lomb Scargle method and Cosinor analysis. Results: Serum uric acid was higher in men than in women older than 13 years (p<0.05). Compared with 0-12 year group, uric acid increased in men but not in women older than 13 years (p<0.05). Circannual (12 months) and transyear (17 months) rhythm components were detected, but they were significant only in adult individuals (>26 years, p<0.05). Cosinor analysis showed that midline estimating statistic of rhythm (MESOR) values were higher in men (range: 353-368 mu mol/L) than in women (range: 240-278 mu mol/L; p<0.05), independent of the age and rhythm component. The extent of predictable change within a cycle, approximated by the double amplitude, represented up to 20% of the corresponding MESOR. Conclusions: Serum uric acid biorhythm is dependent on gender and age and it may have relevant influence on preanalytical variability of clinical laboratory results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Identification of nontuberculous mycobacteria (NTM) based on phenotypic tests is time-consuming, labor-intensive, expensive and often provides erroneous or inconclusive results. In the molecular method referred to as PRA-hsp65, a fragment of the hsp65 gene is amplified by PCR and then analyzed by restriction digest; this rapid approach offers the promise of accurate, cost-effective species identification. The aim of this study was to determine whether species identification of NTM using PRA-hsp65 is sufficiently reliable to serve as the routine methodology in a reference laboratory. Results A total of 434 NTM isolates were obtained from 5019 cultures submitted to the Institute Adolpho Lutz, Sao Paulo Brazil, between January 2000 and January 2001. Species identification was performed for all isolates using conventional phenotypic methods and PRA-hsp65. For isolates for which these methods gave discordant results, definitive species identification was obtained by sequencing a 441 bp fragment of hsp65. Phenotypic evaluation and PRA-hsp65 were concordant for 321 (74%) isolates. These assignments were presumed to be correct. For the remaining 113 discordant isolates, definitive identification was based on sequencing a 441 bp fragment of hsp65. PRA-hsp65 identified 30 isolates with hsp65 alleles representing 13 previously unreported PRA-hsp65 patterns. Overall, species identification by PRA-hsp65 was significantly more accurate than by phenotype methods (392 (90.3%) vs. 338 (77.9%), respectively; p < .0001, Fisher's test). Among the 333 isolates representing the most common pathogenic species, PRA-hsp65 provided an incorrect result for only 1.2%. Conclusion PRA-hsp65 is a rapid and highly reliable method and deserves consideration by any clinical microbiology laboratory charged with performing species identification of NTM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate accuracy, precision and robustness of two methods to obtain silage samples, in comparison with extraction of liquor by manual screw-press. Wet brewery residue alone or combined with soybean hulls and citrus pulp were ensiled in laboratory silos. Liquor was extracted by a manual screw-press and a 2-mL aliquot was fixed with 0.4 mL formic acid. Two 10-g silage samples from each silo were diluted in 20 mL deionized water or 17% formic acid solution (alternative methods). Aliquots obtained by the three methods were used to determine the silage contents of fermentation end-products. The accuracy of the alternative methods was evaluated by comparing mean bias of estimates obtained by manual screw-press and by alternative methods, whereas precision was assessed by the root mean square prediction error and the residual error. Robustness was determined by studying the interaction between bias and chemical components, pH, in vitro dry matter digestibility (IVDMD) and buffer capacity. The 17% formic acid method was more accurate for estimating acetic, butyric and lactic acids, although it resulted in low overestimates of propionic acid and underestimates of ethanol. The deionized water method overestimated acetic and propionic acids and slightly underestimated ethanol. The 17% formic acid method was more precise than deionized water for estimating all organic acids and ethanol. The robustness of each method with respect to variation in the silage chemical composition, IVDMD and pH is dependent on the fermentation end-product at evaluation. The robustness of the alternative methods seems to be critical at the determination of lactic acid and ethanol contents.