7 resultados para distributed control and estimation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polychlorinated biphenyls (PCBs) and organochlorine pesticides are compounds that do not occur naturally in the environment and are not easily degraded by chemical or microbiological action. In the present work, those compounds were analysed in unhatched penguin eggs and whole krill collected in Admiralty Bay, King George Island, Antarctica in the austral summers of 2004-2005 and 2005-2006. The compounds found in higher levels (in a wet weight basis) were, in most of the egg samples, the PCBs (2.53-78.7 ng g(-1)), DDTs (2.07-38.0 ng g(-1)) and HCB (4.99-39.1 ng g(-1)) and after Kruskal-Wallis ANOVA, the occurrence seemed to be species-specific for the Pygoscelis genus. In all of the cases, the levels found were not higher than the ones in Arctic birds in a similar trophic level. The krill samples analysis allowed estimating the biomagnification factors (which resulted in up to 363 for HCB, one order of magnitude higher than DDTs and chlordanes and two orders of magnitude higher than the other groups) of the compounds found in eggs, whose only source of contamination is the female-offspring transfer. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Exercise training is a non-pharmacological strategy for treatment of heart failure. Exercise training improves functional capacity and quality of life in patients. Moreover, exercise training reduces muscle sympathetic nerve activity (MSNA) and peripheral vasoconstriction. However, most of these studies have been conducted in middle-aged patients. Thus, the effects of exercise training in older patients are much less understood. The present study was undertaken to investigate whether exercise training improves functional capacity, muscular sympathetic activation and muscular blood flow in older heart failure patients, as it does in middle-aged heart failure patients. Design: Fifty-two consecutive outpatients with heart failure from the database of the Unit of Cardiovascular Rehabilitation and Physiology Exercise were divided by age (middle-aged, defined as 45-59 years, and older, defined as 60-75 years) and exercise status (trained and untrained). Methods: MSNA was recorded directly from the peroneal nerve using the microneurography technique. Forearm Blood Flow (FBF) was measured by venous occlusion plethysmography. Functional capacity was evaluated by cardiopulmonary exercise test. Results: Exercise training significantly and similarly increased FBF and peak VO2 in middle-aged and older heart failure patients. In addition, exercise training significantly and similarly reduced MSNA and forearm vascular resistance in these patients. No significant changes were found in untrained patients. Conclusion: Exercise training improves neurovascular control and functional capacity in heart failure patients regardless of age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to retrospectively report the results of interventions for controlling a vancomycin-resistant enterococcus (VRE) outbreak in a tertiary-care pediatric intensive care unit (PICU) of a University Hospital. After identification of the outbreak, interventions were made at the following levels: patient care, microbiological surveillance, and medical and nursing staff training. Data were collected from computer-based databases and from the electronic prescription system. Vancomycin use progressively increased after March 2008, peaking in August 2009. Five cases of VRE infection were identified, with 3 deaths. After the interventions, we noted a significant reduction in vancomycin prescription and use (75% reduction), and the last case of VRE infection was identified 4 months later. The survivors remained colonized until hospital discharge. After interventions there was a transient increase in PICU length-of-stay and mortality. Since then, the use of vancomycin has remained relatively constant and strict, no other cases of VRE infection or colonization have been identified and length-of-stay and mortality returned to baseline. In conclusion, we showed that a bundle intervention aiming at a strict control of vancomycin use and full compliance with the Hospital Infection Control Practices Advisory Committee guidelines, along with contact precautions and hand-hygiene promotion, can be effective in reducing vancomycin use and the emergence and spread of vancomycin-resistant bacteria in a tertiary-care PICU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-element analysis of honey samples was carried out with the aim of developing a reliable method of tracing the origin of honey. Forty-two chemical elements were determined (Al, Cu, Pb, Zn, Mn, Cd, Tl, Co, Ni, Rb, Ba, Be, Bi, U, V, Fe, Pt, Pd, Te, Hf, Mo, Sn, Sb, P, La, Mg, I, Sm, Tb, Dy, Sd, Th, Pr, Nd, Tm, Yb, Lu, Gd, Ho, Er, Ce, Cr) by inductively coupled plasma mass spectrometry (ICP-MS). Then, three machine learning tools for classification and two for attribute selection were applied in order to prove that it is possible to use data mining tools to find the region where honey originated. Our results clearly demonstrate the potential of Support Vector Machine (SVM), Multilayer Perceptron (MLP) and Random Forest (RF) chemometric tools for honey origin identification. Moreover, the selection tools allowed a reduction from 42 trace element concentrations to only 5. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Existing studies of on-line process control are concerned with economic aspects, and the parameters of the processes are optimized with respect to the average cost per item produced. However, an equally important dimension is the adoption of an efficient maintenance policy. In most cases, only the frequency of the corrective adjustment is evaluated because it is assumed that the equipment becomes "as good as new" after corrective maintenance. For this condition to be met, a sophisticated and detailed corrective adjustment system needs to be employed. The aim of this paper is to propose an integrated economic model incorporating the following two dimensions: on-line process control and a corrective maintenance program. Both performances are objects of an average cost per item minimization. Adjustments are based on the location of the measurement of a quality characteristic of interest in a three decision zone. Numerical examples are illustrated in the proposal. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Defining pharmacokinetic parameters and depletion intervals for antimicrobials used in fish represents important guidelines for future regulation by Brazilian agencies of the use of these substances in fish farming. This article presents a depletion study for oxytetracycline (OTC) in tilapias (Orechromis niloticus) farmed under tropical conditions during the winter season. High performance liquid chromatography, with fluorescence detection for the quantitation of OTC in tilapia fillets and medicated feed, was developed and validated. The depletion study with fish was carried out under monitored environmental conditions. OTC was administered in the feed for five consecutive days at daily dosages of 80 mg/kg body weight. Groups of ten fish were slaughtered at 1, 2, 3, 4, 5, 8, 10, 15, 20, and 25 days after medication. After the 8th day posttreatment, OTC concentrations in the tilapia fillets were below the limit of quantitation (13 ng/g) of the method. Linear regression of the mathematical model of data analysis presented a coefficient of 0.9962. The elimination half- life for OTC in tilapia fillet and the withdrawal period were 1.65 and 6 days, respectively, considering a percentile of 99% with 95% of confidence and a maximum residue limit of 100 ng/g. Even though the study was carried out in the winter under practical conditions where water temperature varied, the results obtained are similar to others from studies conducted under controlled temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.