10 resultados para block designs

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CLN is a frequent histological finding in biopsies after pediatric: LT, and its pathogenesis has not yet been fully clarified and has different causes. Among the vascular causes, VOB is sometimes difficult to diagnose, especially when technical variants such as split-liver, reduced-liver, or living-related LT are utilized. Three liver-transplanted malnourished children (ages 12, 20, and 28 months) developed altered LFTs and post-operative ascites with right pleural effusion (two cases) and jaundice (one case). Doppler ultrasound examinations were normal and liver biopsies showed CLN interpreted as severe ACR. There were no responses to the medical treatment. Additional investigation with CT angiography suggested obstructed hepatic vein drainage, which was confirmed by interventional radiology and angioplasty of the anastomosis between the hepatic vein and the inferior vena cava, with clinical and histological resolution. It is concluded that in malnourished children undergoing LT with technical variations, in which the occurrence of severe ACR is usually less common because of the severity of the patient condition, the finding of CLN should raise the possibility of VOB, so that excessive immunosuppression and its consequences can be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to examine unbuilt residential projects designed by Vilanova Artigas. The formal and spatial conception of these projects is investigated through physical models. The object of this research project consists of the unbuilt residential projects designed by Vilanova Artigas in Sao Paulo that are available in FAUUSP's digital Library. The results indicate that physical models contribute to a better interpretation of unbuilt architectural design, both from the conceptual and aesthetic and from the functional and technical point of view. The original contribution lies in the object, i.e. the unbuilt projects, in the method, using physical models for analysis, and in the objective, viz. to establish a relationship between Artigas' built works and his unbuilt residential projects in order to better understand the design's spatial conception and its architectural approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Masonry spandrels together with shear walls are structural components of a masonry building subjected to lateral loads. Shear walls are the main components of this structural system, even if masonry spandrels are the elements that ensure the connection of shear wall panels and the distribution of stresses through the masonry piers. The use of prefabricated truss type bars in the transversal and longitudinal directions is usually considered a challenge, even if the simplicity of the applications suggested here alleviate some of the possible difficulties. This paper focus on the experimental behavior of masonry spandrels reinforced with prefabricated trusses, considering different possibilities for the arrangement of reinforcement and blocks. Reinforced spandrels with three and two hollow cell concrete blocks and with different reinforcement ratios have been built and tested using a four and three point loading test configuration. Horizontal bed joint reinforcement increased the capacity of deformation as well as the ultimate load, leading to ductile responses. Vertical reinforcement increased the shear strength of the masonry spandrels and its distribution play a central role on the shear behavior. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are fibers in the left ventricle (LV) (LV middle network) that in around one third of cases may be considered a true septal fascicle that arises from the common left bundle. Its presence and the evidence that there are 3 points of activation onset in the LV favor the quadrifascicular theory of the intravantricular activation of both ventricles. Since the 70s, different authors have suggested that the block of the left middle fibers (MS)/left septal fascicle may explain different electrocardiographic (ECG) patterns. The 2 hypothetically based criteria that are in some sense contradictory include: a) the lack of septal "q" wave due to first left and later posteriorly shifting of the horizontal plane loop and b) the presence of RS in lead V-2 (V-1-V-2) due to some anterior shifting of the horizontal plane vectorcardiogram loop. However, there are many evidence that the lack of septal q waves can be also explained by predivisional first-degree left bundle-branch block and that the RS pattern in the right precordial leads may be also explained by first-degree right bundle-branch block. The transient nature of these patterns favor the concept that some type of intraventricular conduction disturbance exists but a doubt remains about its location. Furthermore, the RS pattern could be explained by many different normal variants. To improve our understanding whether these patterns are due to MF/left septal fascicle block or other ventricular conduction disturbances (or both), it would be advisable: 1) To perform more histologic studies (heart transplant and necropsy) of the ventricular conduction system; 2) To repeat prior experimental studies using new methodology/technology to isolate the MF; and 3) To change the paradigm: do not try to demonstrate if the block of the fibers produces an ECG change but to study with new electroanatomical imaging techniques, if these ECG criteria previously described correlate or not with a delay of activation in the zone of the LV that receives the activation through these fibers or in other zones. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local anesthetic efficacy of tramadol has been reported following intradermal application. Our aim was to investigate the effect of perineural tramadol as the sole analgesic in two pain models. Male Wistar rats (280-380 g; N = 5/group) were used in these experiments. A neurostimulation-guided sciatic nerve block was performed and 2% lidocaine or tramadol (1.25 and 5 mg) was perineurally injected in two different animal pain models. In the flinching behavior test, the number of flinches was evaluated and in the plantar incision model, mechanical and heat thresholds were measured. Motor effects of lidocaine and tramadol were quantified and a motor block score elaborated. Tramadol, 1.25 mg, completely blocked the first and reduced the second phase of the flinching behavior test. In the plantar incision model, tramadol (1.25 mg) increased both paw withdrawal latency in response to radiant heat (8.3 +/- 1.1, 12.7 +/- 1.8, 8.4 +/- 0.8, and 11.1 +/- 3.3 s) and mechanical threshold in response to von Frey filaments (459 +/- 82.8, 447.5 +/- 91.7, 320.1 +/- 120, 126.43 +/- 92.8 mN) at 5, 15, 30, and 60 min, respectively. Sham block or contralateral sciatic nerve block did not differ from perineural saline injection throughout the study in either model. The effect of tramadol was not antagonized by intraperitoneal naloxone. High dose tramadol (5 mg) blocked motor function as well as 2% lidocaine. In conclusion, tramadol blocks nociception and motor function in vivo similar to local anesthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronic interactions between the [Cu(opba)]2- anions (where opba is orthophenylenebis (oxamato)) and single-wall carbon nanotubes (SWCNTs) were investigated by resonance Raman spectroscopy. The opba can form molecular magnets, and the interactions of opba with SWCNTs can produce materials with very different magnetic/electronic properties. It is observed that the electronic interaction shows a dependence on the SWCNT diameter independent of whether they are metallic or semiconducting, although the interaction is stronger for metallic tubes. The interaction also is dependent on the amount of complex that is probably adsorbed on the carbon surface of the SWCNTs. Some charge transfer can be also occurring between the metallic complex and the SWCNTs. Copyright (c) 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the in vitro fracture resistance of roots with glass-fiber and metal dowels with different designs. METHODS: Fifty-endodontically treated maxillary central incisors were embedded in acrylic resin. Ten of them received only the coronary preparation, and the remaining forty were embedded (except for 4mm of the cervical area) after removing the clinical crowns. Specimens were divided into five groups (n=10): control (teeth with only coronary preparation), cylindrical cast dowel, conical cast dowel, cylindrical glass-fiber dowel and conical glass-fiber dowel. Specimens were subjected to an increasing compressive load (N) until fracture. RESULTS: ANOVA indicated significant difference (P<.05) among the groups, and the Tukey-Kramer´s test identified these differences. The control group (867±243 N) presented the highest values and was statistically similar to cylindrical glass-fiber dowel group (711±180 N). There is no significant difference among the metal dowel cylindrical (435±245 N) or conical (585±164 N) group and conical glass-fiber dowel (453±112 N). Cylindrical glass-fiber dowel (711±180 N) and conical cast dowel and core (585±164 N) groups had intermediate values and did not differ from each other. CONCLUSIONS: Cylindrical glass fiber dowels represent a viable alternative to the cast-metal dowel cylindrical or conical. Cylindrical glass fiber dowels also increase endodontically treated incisors' resistance to fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clay-containing nanocomposites of polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) copolymers having cylindrical domains were obtained by melt extrusion using a tape die. One type of sample (SEBS-MA) had maleic anhydride attached to the middle block. Two types of organoclays were added, namely Cloisite 20A and Cloisite 30B. Small angle X-ray scattering and transmission electron microscopy (TEM) analyses showed that the addition of 20A clay to SEBS and SEBS-MA resulted in nanocomposites with intercalated and partially exfoliated structures, respectively. The addition of 30B clay to SEBS and SEBS-MA promoted the formation of composites containing relatively large micron-sized and partially exfoliated clay particles, respectively. Our TEM analysis revealed that clay particles embedded in SEBS are preferably in contact with the polystyrene cylindrical domains, while in SEBS-MA they are in contact with the maleated matrix. The extrusion processing promoted alignment of the axes of the polystyrene cylinders along the extrusion direction in all samples, and the basal planes of the clay particles were mostly parallel to the main external surfaces of the extruded tapes. © 2013 Society of Chemical Industry.