In vitro fracture resistance of glass-fiber and cast metal posts with different designs


Autoria(s): Pasqualin, Fábio Henrique; Giovani, Alessandro Rogério; Sousa Neto, Manoel Damião de; Paulino, Silvana Maria; Vansan, Luiz Pascoal
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

04/11/2013

04/11/2013

2012

Resumo

PURPOSE: To evaluate the in vitro fracture resistance of roots with glass-fiber and metal dowels with different designs. METHODS: Fifty-endodontically treated maxillary central incisors were embedded in acrylic resin. Ten of them received only the coronary preparation, and the remaining forty were embedded (except for 4mm of the cervical area) after removing the clinical crowns. Specimens were divided into five groups (n=10): control (teeth with only coronary preparation), cylindrical cast dowel, conical cast dowel, cylindrical glass-fiber dowel and conical glass-fiber dowel. Specimens were subjected to an increasing compressive load (N) until fracture. RESULTS: ANOVA indicated significant difference (P<.05) among the groups, and the Tukey-Kramer´s test identified these differences. The control group (867±243 N) presented the highest values and was statistically similar to cylindrical glass-fiber dowel group (711±180 N). There is no significant difference among the metal dowel cylindrical (435±245 N) or conical (585±164 N) group and conical glass-fiber dowel (453±112 N). Cylindrical glass-fiber dowel (711±180 N) and conical cast dowel and core (585±164 N) groups had intermediate values and did not differ from each other. CONCLUSIONS: Cylindrical glass fiber dowels represent a viable alternative to the cast-metal dowel cylindrical or conical. Cylindrical glass fiber dowels also increase endodontically treated incisors' resistance to fracture.

Identificador

Rev. odonto ciênc.,v.27,n.1,p.52-57,2012

1980-6523

http://www.producao.usp.br/handle/BDPI/40556

10.1590/S1980-65232012000100010

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1980-65232012000100010&lng=en&nrm=iso&tlng=en

http://www.scielo.br/scielo.php?script=sci_abstract&pid=S1980-65232012000100010&lng=en&nrm=iso&tlng=en

http://www.scielo.br/scielo.php?script=sci_pdf&pid=S1980-65232012000100010&lng=en&nrm=iso&tlng=en

Idioma(s)

eng

Publicador

Pontifícia Universidade Católica do Rio Grande do Sul

Relação

Revista Odonto Ciência

Direitos

openAccess

Palavras-Chave #Fiber dowel #metallic dowel #dowel failure #resistance to fracture #Pino de fibra #pino metálico #falha de pino #resistência à fratura
Tipo

article

original article