Aims: The long-term clinical performance of drug-eluting stents (DES) coated with biodegradable polymers is poorly known. Methods and results: A total of 274 coronary patients were randomly allocated to paclitaxel-eluting stents, sirolimus-eluting stents, or bare metal stems (2:2:1 ratio). The two DES used the same biodegradable polymers and were identical except for the drug. At three years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9.0% vs. 7.1; p=0.6), but lower risk of repeat interventions (10.0% vs. 29.9%; p<0.01) than controls with bare stents. The cumulative 3-year incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (first year: 1.8%; second year: 0.4%; third year: zero). There were no significant differences in outcomes between paclitaxel- and sirolimus-eluting stents. Conclusions: The biodegradable-polymer coated DES releasing either paclitaxel or sirolimus were effective in reducing the 3-year rate of re-interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept behind a biodegradable ligament device is to temporarily replace the biomechanical functions of the ruptured ligament, while it progressively regenerates its capacities. However, there is a lack of methods to predict the mechanical behaviour evolution of the biodegradable devices during degradation, which is an important aspect of the project. In this work, a hyper elastic constitutive model will be used to predict the mechanical behaviour of a biodegradable rope made of aliphatic polyesters. A numerical approach using ABAQUS is presented, where the material parameters of the model proposal are automatically updated in correspondence to the degradation time, by means of a script in PYTHON. In this method we also use a User Material subroutine (UMAT) to apply a failure criterion base on the strength that decreases according to a first order differential equation. The parameterization of the material model proposal for different degradation times were achieved by fitting the theoretical curves with the experimental data of tensile tests on fibres. To model all the rope behaviour we had considered one step of homogenisation considering the fibres architectures in an elementary volume. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of glycerol concentration (C-g), process temperature (T-p), drying temperature (T-s), and relative humidity (RH) on the properties of achira flour films was initially assessed. The optimized process conditions were C-g of 17g glycerol/100g flour, T-p of 90 degrees C, T-s of 44.8 degrees C, and RH of 36.4%. The films produced under these conditions displayed high mechanical strength (7.0 MPa), low solubility (38.3%). and satisfactory elongation values (14.6%). This study showed that achira flour is a promising source for the development of biodegradable films with good mechanical properties, low water vapor permeability, and solubility compared to films based on other tubers. (c) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this this study, glycerol content and its incorporation method on tensile and barrier properties of biodegradable films (BF) based on cassava starch were analyzed. ANOVA showed that the glycerol incorporation method did not influence the results (P > 0.05), however the glycerol content influenced significantly the tensile and barrier properties of the films (P < 0.05). Films prepared with lower glycerol content presented better tensile and barrier properties than films with higher content. Films were then prepared with addition of clay nanoparticles and their tensile and barrier properties and glass transition temperature were measured. ANOVA indicated that both glycerol and clay nanoparticles influenced significantly the tensile and barrier properties (P < 0.05), diminishing film permeability when clay nanoparticles were present, while the glass transition temperature was not influenced (P > 0.05). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A rápida endotelização pós-implante de stent é ocorrência desejável por teoricamente reduzir a possibilidade de trombose do stent. OBJETIVO: Avaliar a extensão da endotelização de hastes de stents eluidores de sirolimus (liberados da face luminal e abluminal e abluminal exclusivamente) em artérias ilíacas de coelhos. MÉTODOS: Foram implantados em artérias ilíacas de 10 coelhos quatro stents eluidores de sirolimus na face luminal e abluminal, três stents eluidores de sirolimus na face abluminal, seis stents recobertos com polímero e quatro stents sem recobrimento. Após quatro semanas, foi realizada eutanásia e utilizou-se microscopia eletrônica de varredura para quantificação da área de hastes de stent exposta e da porcentagem de endotelização. RESULTADOS: A área (média ± DP) (mm²) de hastes expostas de stent sem recobrimento, stent recoberto com polímero, stent eluidor de sirolimus na face luminal e abluminal e stent eluidor de sirolimus na face abluminal foi de 0,12 ± 0,08; 0,09 ± 0,12; 0,60 ± 0,67 e 0,05 ± 0,04 respectivamente (p = 0,120). A porcentagem de endotelização (média ± DP) (%) de stent sem recobrimento, stent recoberto com polímero, stent eluidor de sirolimus na face luminal e abluminal e stent eluidor de sirolimus na face abluminal foi de 99 ± 01; 99 ± 0; 97 ± 03 e 99 ± 0 respectivamente (p = 0,133). CONCLUSÃO: Após quatro semanas de implante em artérias ilíacas de coelhos, os stents com liberação de sirolimus tanto da face luminal e abluminal quanto da face abluminal exclusivamente apresentaram taxas de endotelização de hastes de stent semelhantes aos apresentados nos demais tipos de stents sem eluição de medicamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Baseados na hipótese de que a neoíntima encontrada em stents farmacológicos (SFs) com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva e de que a tomografia de coerência óptica (TCO) é um método eficaz para a avaliação sequencial da neoíntima, objetivamos, neste estudo experimental, comparar os achados da TCO aos 28 dias e aos 90 dias em dois tipos de SF com polímeros biodegradáveis: o stent liberador de sirolimus (Inspiron®, Scitech) e o stent liberador de biolimus A9 (Biomatrix®, Biosensors International). MÉTODOS: No total, 6 porcos não-ateroscleróticos foram submetidos a implante de 6 stents Inspiron® e de 6 stents Biomatrix®. Cada porco recebeu os dois tipos de stent, um em cada artéria coronária (descendente anterior e circunflexa) e após 28 dias e 90 dias foram realizadas avaliações qualitativas intrastent a cada milímetro com TCO. RESULTADOS: A avaliação qualitativa, feita por pareamento milímetro a milímetro intrastent, evidenciou neoíntima heterogênea em 39% aos 28 dias e em 0% aos 90 dias, presença de tecido intraluminal em 18% aos 28 dias e em 0% aos 90 dias, irregularidade luminal em 62% aos 28 dias e em 2% aos 90 dias (P < 0,005). Não houve diferença entre os grupos quanto à qualidade da neoíntima ao longo do tempo (P > 0,05). CONCLUSÕES: Os achados à TCO corroboram a hipótese de que a neoíntima encontrada em SFs com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva. A evidência experimental mais significativa é a mudança das características da neoíntima observada à TCO sequencial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The e-Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth (e-HEALING) registry was designed to capture clinical data on the use of the endothelial progenitor cell capture stent (ECS) in routine clinical practice. In this analysis, we investigated the 12-month clinical outcomes in patients treated with an ECS for a bifurcation lesion. Methods The worldwide, prospective, nonrandomized e-HEALING registry aimed to enrol 5000 patients treated for coronary artery disease with one or more ECS between October 2005 and October 2007. Clinical follow-up was obtained at 1, 6, and 12 months. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, myocardial infarction, and target vessel revascularization at 12 months. Results A total of 573 patients were treated for at least one bifurcation lesion and were assessed in the current analysis. Baseline characteristics showed a median age of 65 years; 21% were diabetic patients and 36% had unstable angina. A total of 63% of the bifurcation lesions were located in the left artery descending and the mean stent length was 20.7 +/- 12.6 mm. At 12 months, TVF was 12.7% and target lesion revascularization was 7.5%. Definite or probable stent thrombosis occurred in 1.7% of the patients. Moreover, one or more stents per lesion [hazard ratio (HR): 2.79, 95% confidence interval (CI): 1.60-4.86, P < 0.001], predilatation (HR: 0.39, 95% CI: 0.17-0.87, P = 0.023), and lesions located in the right coronary artery (HR: 4.56, 95% CI: 1.07-19.5, P = 0.041) were independent predictors of TVF. Conclusion In the e-HEALING registry, coronary bifurcation stenting with the ECS results in favorable clinical outcomes and low incidences of repeat revascularization and stent thrombosis. Coron Artery Dis 23:201-207 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work addresses the synthesis of carbon nanomaterials (CNMs) by up-cycling common solid wastes. These feedstocks could supersede the use of costly and often toxic or highly flammable chemicals, such as hydrocarbon gases, carbon monoxide, and hydrogen, which are commonly used as feedstocks in current nanomanufacturing processes for CNMs. Agricultural sugar cane bagasse and corn residues, scrap tire chips, and postconsumer polyethylene (PE) and polyethylene terephthalate (PET) bottle shreddings were either thermally treated by sole pyrolysis or by sequential pyrolysis and partial oxidation. The resulting gaseous carbon-bearing effluents were then channeled into a heated reactor. CNMs, including carbon nanotubes, were catalytically synthesized therein on stainless steel meshes. This work revealed that the structure of the resulting CNMs is determined by the feedstock type, through the disparate mixtures of carbon-bearing gases generated when different feedstocks are pyrolyzed. CNM characterization was conducted by scanning and transmission electron microscopy as well as by Raman spectroscopy and by thermogravimetric analysis. Gas chromatography was used to characterize the gases in the synthesis chamber. This work demonstrated an alternative method for efficient manufacturing of CNMs using both biodegradable and nonbiodegradable agricultural and municipal carbonaceous wastes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low liquid-solid ratio (LSR) can be used to obtain high-content xylo-oligosaccharide (XOS) spend liquor by hot water pretreatment. Developing a technology based on low LSR results in more efficient water usage in the system and thus in lower capital and operating costs. Xylans from xylan rich agro-industrial waste are abundant hemicellulosic polymers with enormous potential for industrial applications. Currently, freeze-dried xylo-oligosaccharides are used as bio-based polymers and hydrolysates containing high xylose contents are converted to several chemical products. In this study, sugarcane bagasse was treated with water at low LSRs and mild temperatures in order to assess the effects of varying the pretreatment conditions on the xylo-oligosaccharide and xylose concentrations, and use a central composite experimental design to optimize the process parameters. The pretreatments were performed in the ranges temperature: 143.3-176.7 degrees C, time: 20-70 min and LSR: 1 : 1 to 11 : 1 (g g(-1)). The maximum concentrations of xylose and xylan were 13.76 and 36.18 g L-1 (equivalent to 48.29 g L-1 of xylan), respectively, which were achieved by treating bagasse at 170 degrees C for 60 min, with LSR of 3 g g(-1). The amount of xylan removed under these conditions was almost 57%. The soluble xylan consisted mainly of xylo-oligosaccharides (74 wt% of the identified compound in the spent liquor).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To evaluate the results of duodenal stenting for palliation of gastroduodenal malignant obstruction by using a gastric outlet obstruction score (GOOS). METHODS: A prospective, non-randomized study was performed at a tertiary center between August 2005 and April 2010. Patients were eligible if they had malignant gastric outlet obstruction (GOO) and were not candidates for surgical treatment. Medical history and patient demographics were collected at baseline. Scheduled interviews were made on the day of the procedure and 15, 30, 90 and 180 d later or unscheduled as necessary. RESULTS: Fifteen patients (6 male, 9 female; median age 61 years) with GOO who had undergone duodenal stenting were evaluated. Ten patients had metastasis at baseline (66.6%) and 14 were unable to accept oral intake (93.33%), including 7 patients who were using a feeding tube. Laboratory data showed biliary obstruction in eight cases (53.33%); all were submitted to biliary drainage. Two patients developed obstructive symptoms due to tumor ingrowth after 30 d and another due to tumor overgrowth after 180 d. Two cases of stent migration occurred. A good response to treatment was observed, with a mean time of approximately 1 d (19 h) until toleration of a liquid diet and slightly more than 2 d for both soft solids (51 h) and a solid food/normal diet (55 h). The mean time to first failure to maintain liquid intake (GODS >= 1) was 93 d. During follow-up, the mean time to first failure to maintain the previously achieved GODS of 2-3 (solid/semi-solid food), considered technical failure, was 71 d. On the basis of oral intake a GODS is defined: 0 for no oral intake; 1 for liquids only; 2 for soft solids only; 3 for low-residue or full diet. CONCLUSION: Enteral stenting to alleviate gastroduodenal malignant obstruction improves quality of life in patients with limited life expectancy, which can be evaluated by using a GOO scoring system. (C) 2012 Baishideng. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous (TM) endothelial progenitor cell capturing R stent (TM) placement in patients from the e-HEALING registry. Background: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. Methods: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. Results: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.651.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.551.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. Conclusions: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study assess the effects of bioceramic and poly(lactic-co-glycolic acid) composite (BCP/PLGA) on the viability of cultured macrophages and human dental pulp fibroblasts, and we sought to elucidate the temporal profile of the reaction of pulp capping with a composite of bioceramic of calcium phosphate and biodegradable polymer in the progression of delayed dentine bridge after (30 and 60 days) in vivo. Histological evaluation of inflammatory infiltrate and dentin bridge formation were performed after 30 and 60 days. There was similar progressive fibroblast growth in all groups and the macrophages showed viability. The in vivo study showed that of the three experimental groups: BCP/PLGA composite, BCP and calcium hydroxide (Ca(OH)(2)) dentin bridging was the most prevalent (90 %) in the BCP/PLGA composite after 30 days, mild to moderate inflammatory response was present throughout the pulp after 30 days. After 60 days was observed dentine bridging in 60 % and necrosis in 40 %, in both groups. The results indicate that understanding BCP/PLGA composite is biocompatible and by the best tissue response as compared to calcium hydroxide in direct pulp capping may be important in the mechanism of delayed dentine bridge after 30 and 60 days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Although the release of cardiac biomarkers after percutaneous (PCI) or surgical revascularization (CABG) is common, its prognostic significance is not known. Questions remain about the mechanisms and degree of correlation between the release, the volume of myocardial tissue loss, and the long-term significance. Delayed-enhancement of cardiac magnetic resonance (CMR) consistently quantifies areas of irreversible myocardial injury. To investigate the quantitative relationship between irreversible injury and cardiac biomarkers, we will evaluate the extent of irreversible injury in patients undergoing PCI and CABG and relate it to postprocedural modifications in cardiac biomarkers and long-term prognosis. Methods/Design: The study will include 150 patients with multivessel coronary artery disease (CAD) with left ventricle ejection fraction (LVEF) and a formal indication for CABG; 50 patients will undergo CABG with cardiopulmonary bypass (CPB); 50 patients with the same arterial and ventricular condition indicated for myocardial revascularization will undergo CABG without CPB; and another 50 patients with CAD and preserved ventricular function will undergo PCI using stents. All patients will undergo CMR before and after surgery or PCI. We will also evaluate the release of cardiac markers of necrosis immediately before and after each procedure. Primary outcome considered is overall death in a 5-year follow-up. Secondary outcomes are levels of CK-MB isoenzyme and I-Troponin in association with presence of myocardial fibrosis and systolic left ventricle dysfunction assessed by CMR. Discussion: The MASS-V Trial aims to establish reliable values for parameters of enzyme markers of myocardial necrosis in the absence of manifest myocardial infarction after mechanical interventions. The establishments of these indices have diagnostic value and clinical prognosis and therefore require relevant and different therapeutic measures. In daily practice, the inappropriate use of these necrosis markers has led to misdiagnosis and therefore wrong treatment. The appearance of a more sensitive tool such as CMR provides an unprecedented diagnostic accuracy of myocardial damage when correlated with necrosis enzyme markers. We aim to correlate laboratory data with imaging, thereby establishing more refined data on the presence or absence of irreversible myocardial injury after the procedure, either percutaneous or surgical, and this, with or without the use of cardiopulmonary bypass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Fast post-implantation stent endothelialization is desirable for theoretically reducing the possibility of stent thrombosis. Objective: To evaluate the extent of sirolimus-eluting stent strut endothelialization (delivered from the luminal and abluminal aspects or abluminal aspect only) in the iliac arteries of rabbits. Methods: The iliac arteries of 10 rabbits were implanted with four sirolimus-eluting stents in the luminal and abluminal aspects, three sirolimus-eluting stents in the abluminal aspect, six polymer-coated stents, and four uncoated stents. After four weeks, the rabbits were euthanized and scanning electron microscopy was performed to quantify the area of exposed stent strut as well as the percentage of endothelialization. Results: The area (mean +/- SD) (mm(2)) of exposed uncoated stent struts, polymer-coated stents, sirulimus-eluting stent in the abluminal and luminal aspects and sirolimus-eluting stent in the abluminal aspect was 0.12 +/- 0.08, 0.09 +/- 0.12, 0.60 +/- 0.67 and 0.05 +/- 0.04, respectively (p = 0.120). The percentage of endothelialization (mean +/- SD) (%) of uncoated stents, polymer-coated stents, sirolimus-eluting stents in the luminal and abluminal aspects and sirolimus-eluting stents in the abluminal aspect was 99 +/- 01, 99 +/- 0. 97 +/- 03 and 99 +/- 0, respectively (p = 0.133). Conclusion: After four weeks of implantation in the iliac arteries of rabbits, both the sirolimus-eluting stents in the luminal plus abluminal aspects and those in the abluminal aspect only showed stent strut endothelialization rates similar to those of the other types of non-drug eluting stents. (Arq Bras Cardiol 2012;99(6):1123-1128)