Assessment of Stent Strut Endothelialization in Iliac Arteries of Rabbits
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
01/11/2013
01/11/2013
2012
|
Resumo |
Background: Fast post-implantation stent endothelialization is desirable for theoretically reducing the possibility of stent thrombosis. Objective: To evaluate the extent of sirolimus-eluting stent strut endothelialization (delivered from the luminal and abluminal aspects or abluminal aspect only) in the iliac arteries of rabbits. Methods: The iliac arteries of 10 rabbits were implanted with four sirolimus-eluting stents in the luminal and abluminal aspects, three sirolimus-eluting stents in the abluminal aspect, six polymer-coated stents, and four uncoated stents. After four weeks, the rabbits were euthanized and scanning electron microscopy was performed to quantify the area of exposed stent strut as well as the percentage of endothelialization. Results: The area (mean +/- SD) (mm(2)) of exposed uncoated stent struts, polymer-coated stents, sirulimus-eluting stent in the abluminal and luminal aspects and sirolimus-eluting stent in the abluminal aspect was 0.12 +/- 0.08, 0.09 +/- 0.12, 0.60 +/- 0.67 and 0.05 +/- 0.04, respectively (p = 0.120). The percentage of endothelialization (mean +/- SD) (%) of uncoated stents, polymer-coated stents, sirolimus-eluting stents in the luminal and abluminal aspects and sirolimus-eluting stents in the abluminal aspect was 99 +/- 01, 99 +/- 0. 97 +/- 03 and 99 +/- 0, respectively (p = 0.133). Conclusion: After four weeks of implantation in the iliac arteries of rabbits, both the sirolimus-eluting stents in the luminal plus abluminal aspects and those in the abluminal aspect only showed stent strut endothelialization rates similar to those of the other types of non-drug eluting stents. (Arq Bras Cardiol 2012;99(6):1123-1128) Secretariat of Science, Technology and Strategic Inputs(SCTIE)/Department of Science and Technology of the Ministry of Health Secretariat of Science, Technology and Strategic Inputs(SCTIE)/Department of Science and Technology of the Ministry of Health National Council for Scientific and Technologic Development(CNPq) National Council for Scientific and Technologic Development(CNPq) Ministry of Science and Technology Ministry of Science and Technology Foundation of Research Support of the State of Sao Paulo(FAPESP) Foundation of Research Support of the State of Sao Paulo(FAPESP) |
Identificador |
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, RIO DE JANEIRO, v. 99, n. 6, supl., Part 1, pp. 1123-1127, DEC, 2012 0066-782X http://www.producao.usp.br/handle/BDPI/37491 10.1590/S0066-782X2012005000103 |
Idioma(s) |
eng |
Publicador |
ARQUIVOS BRASILEIROS CARDIOLOGIA RIO DE JANEIRO |
Relação |
ARQUIVOS BRASILEIROS DE CARDIOLOGIA |
Direitos |
openAccess Copyright ARQUIVOS BRASILEIROS CARDIOLOGIA |
Palavras-Chave | #DRUG ELUTING STENTS #ARTERIES #SIROLIMUS #MICROSCOPY, ELECTRON, SCANNING #DRUG-ELUTING STENTS #CARDIAC & CARDIOVASCULAR SYSTEMS |
Tipo |