17 resultados para ammonossidazione, etanolo, acetonitrile

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive analytical method for simultaneous determination of anastrozole, bicalutamide, and tamoxifen as well as their synthetic impurities, anastrozole pentamethyl, bicalutamide 3-fluoro-isomer, and tamoxifen e-isomer, was developed and validated by using high performance liquid chromatography (HPLC). The separation was achieved on a Symmetry (R) C-8 column (100 x 4.6 mm i.d., 3.5 mu m) at room temperature (+/- 24 degrees C), with a mobile phase consisting of acetonitrile/water containing 0.18% N,N dimethyloctylamine and pH adjusted to 3.0 with orthophosphoric acid (46.5/53.5, v/v) at a flow rate of 1.0 mL min(-1) within 20 min. The detection was made at a wavelength of 270 nm by using ultraviolet (UV) detector. No interference peaks from excipients and relative retention time indicated the specificity of the method. The calibration curve showed correlation coefficients (r) > 0.99 calculated by linear regression and analysis of variance (ANOVA). The limit of detection (LOD) and limit of quantitation (LOQ), respectively, were 2.2 and 6.7 mu g mL(-1) for anastrozole, 2.61 and 8.72 mu g mL(-1) for bicalutamide, 2.0 and 6.7 mu g mL(-1) for tamoxifen, 0.06 and 0.22 mu g mL(-1) for anastrozole pentamethyl, 0.02 and 0.07 mu g mL(-1) for bicalutamide 3-fluoro-isomer, and 0.002 and 0.007 mu g mL(-1) for tamoxifen e-isomer. Intraday and interday relative standard deviations (RSDs) were <2.0% (drugs) and <10% (degradation products) as well as the comparison between two different analysts, which were calculated by f test. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemiluminescent reactions of bis(2,4,6-trichlorophenyl)oxalate (TCPO) and bis(2-nitrophenyl)oxalate (2-NPO) with hydrogen peroxide in acetonitrile/water micellar systems (anionic, cationic, and non-ionic) and gamma-cyclodextrin were studied in the presence of fluoranthene or 9,10-diphenylanthracene, imidazole, and two buffer solutions, HTRIS+/TRIS and H2PO4-/HPO42-. The relative chemiluminenscence (CL) intensity is higher in the presence of the cationic (DDAB, CTAC, DODAC, and OTAC), anionic (SDS), and non-ionic (Tween 80) surfactants. In the presence of some non-ionic surfactants (Brij 35, Brij 76, and Tween 20), the CL intensity was partially quenched compared with the reaction with no surfactant. The sensitivity for hydrogen peroxide determination in the range 0.01 x 10(-4) to 1.0 x 10(-4) mol L-1, considering the slope of the calibration curves (maximum peak height of CL vs. concentration), improved with the introduction of DDAH, CTAB, and SDS in HTRIS+/TRIS buffer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, a fast, sensitive and robust method to quantify dextromethorphan, dextrorphan and doxylamine in human plasma using deuterated internal standards (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction (LLE) using diethyl-ether/hexane (80/20, v/v). Extracted samples were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase (acetonitrile/water/formic acid (90/9/1, v/v/v) during 4.0 min at a flow-rate of 1.5 mL min(-1) into a Phenomenex Gemini (R) C18, 5 mu m analytical column (150 x 4.6 mm id.). The calibration curve was linear over the range from 0.2 to 200 ng mL(-1) for dextromethorphan and doxylamine and 0.05 to 10 ng mL(-1) for dextrorphan. The intra-batch precision and accuracy (%CV) of the method ranged from 2.5 to 9.5%, and 88.9 to 105.1%, respectively. Method inter-batch precision (%CV) and accuracy ranged from 6.7 to 10.3%, and 92.2 to 107.1%, respectively. The run-time was for 4 min. The analytical procedure herein described was used to assess the pharmacokinetics of dextromethorphan, dextrorphan and doxylamine in healthy volunteers after a single oral dose of a formulation containing 30 mg of dextromethorphan hydrobromide and 12.5 mg of doxylamine succinate. The method has high sensitivity, specificity and allows high throughput analysis required for a pharmacokinetic study. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high-performance liquid chromatographic method using polar organic mode was developed to analyze albendazole (ABZ), albendazole sulfone (ABZSO(2)) and the chiral and active metabolite albendazole sulfoxide (ABZSOX, ricobendazole) that was further applied in stereoselective fungal biotransformation studies. The chromatographic separation was performed on a Chiralpak AS column using acetonitrile:ethanol (97:3, v/v) plus 0.2% triethylamine and 0.2% acetic acid as the mobile phase at a flow rate of 0.5 mL min(-1). The present study employed hollow fiber liquid-phase microextraction as sample preparation. The method showed to be linear over the concentration range of 25-5000 ng mL(-1) for each ABZSOX enantiomer, 200-10,000 ng mL(-1) for ABZ and 50-1000 ng mL(-1) for ABZSO(2) metabolite with correlation coefficient (r)> 0.9934. The mean recoveries for ABZ, rac-ABZSOX and ABZSO(2) were, respectively, 9%, 33% and 20% with relative standard deviation below 10%. Within-day and between-day precision and accuracy assays for these analytes were studied at three concentration levels and were lower than 15%. This study opens the door regarding the possibility of using fungi in obtaining of the active metabolite ricobendazole. Nigrospora sphaerica (Sacc.) E. W. Mason (5567), Pestalotiopsis foedans (VR8), Papulaspora immersa Hotson (SS13) and Mucor rouxii were able to stereoselectively metabolize ABZ into its chiral metabolite. Among them, the fungus Mucor rouxii was the most efficient in the production of (+)-ABZSOX. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fast and sensitive method for the simultaneous determination of Sudan dyes (I, II, III, and IV) in food samples was developed for the first time using partial filling micellar electrokinectic chromatography-mass spectrometry (MEKC-MS). The use of MEKC was essential to achieve the separation of these neutral analytes, while the partial filling technique was necessary to avoid the contamination of the ion source with non-volatile micelles. MEKC separation and MS detection conditions were optimized in order to achieve a fast, efficient, and sensitive separation of the four dyes. Filling 25% of the capillary with an MEKC solution containing 40 mM ammonium bicarbonate, 25 mM SDS, and 32.5% (v/v) acetonitrile, a baseline separation of the four azo-dyes was obtained in 10 min. Tandem MS was investigated in order to improve the sensitivity and selectivity of the analysis. Limits of detection (LOD) values 5, 8, 15, and 29 times better were obtained for Sudan III, I, II, and IV, respectively, using partial filling MEKC-MS/MS instead of partial filling MEKC-MS. Under optimized conditions, LOD from 0.05 to 0.2 mu g/mL were obtained. The suitability of the developed method was demonstrated through the fast and sensitive determination of Sudan I, II, III, and IV in spiked chilli powder samples. This determination could not be achieved by MEKC-UV due to the existence of several interfering compounds from the matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Determination of organic acids in intracellular extracts and in the cultivation media of marine microalgae aid investigations about metabolic routes related to assimilation of atmospheric carbon by these organisms, which are known by their role in the carbon dioxide sink. The separation of these acids was investigated by hydrophilic interaction liquid chromatography (HILIC) using isocratic elution with a mobile phase composed of 70: 30 v/v acetonitrile/20 mmol/L ammonium acetate buffer (pH 6.8) and detection at 220 nm. HILIC allowed the determinations of glycolic acid, the most important metabolite for the evaluation of the photorespiration process in algae, to be made with better selectivity than that achieved by reversed phase liquid chromatography, but with less detectability. The concentration of glycolic acid was determined in the cultivation media and in intracellular extracts of the algae Tetraselmis gracilis and Phaeodactylum tricornutum submitted to different conditions of aeration: (i) without forced aeration, (ii) aeration with atmospheric air, and (iii) bubbling with N(2). The concentration of glycolic acid had a higher increase as the cultures were aerated with nitrogen, showing higher photorespiratory flux than that occurring in the cultures aerated with atmospheric air.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive method using solid phase microextraction (SPME) and liquid chromatography (LC) with heated online desorption (SPME-LC) was developed and validated to analyze anticonvulsants (AEDs) in human plasma samples. A heated lab-made interface chamber was used in the desorption procedure, which allowed the transference of the whole extracted sample. The SPME conditions were optimized by applying an experimental design. Important factors are discussed such as fiber coating types, pH, extraction time and desorption conditions. The drugs were analyzed by LC, using a C18 column (150 mm x 4.6 mm x 5 mm); and 50 mmol L-1, pH 5.50 ammonium acetate buffer : acetonitrile : methanol (55 : 22 : 23 v/v) as the mobile phase with a flow rate of 0.8 mL min(-1). The suggested method presented precision (intra-assay and inter-assay), linearity and limit of quantification (LOQ) all adequate for the therapeutic drug monitoring (TDM) of AEDs in plasma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Analytic methods were applied and validated to measure residues of chlorfenvinphos, fipronil, and cypermethrin in meat and bovine fat, using the QuEChERS method and gas chromatography-mass spectrometry. For the meat, 2 g of sample, 4mL of acetonitrile, 1.6 g of MgSO4, and 0.4 g of NaCl were used in the liquid-liquid partition, while 80 mg of C18, 80 mg of primary and secondary amine and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction. For the fat, 1 g of sample, 5 mL of hexane, 10 mL of water, 10 mL of acetonitrile, 4 g of MgSO4, and 0.5 g of NaCl were used in the liquid-liquid partition and 50 mg of primary and secondary amine and 150 mg of MgSO4 were used in the dispersive solid-phase extraction. The recovery percentages obtained for the pesticides in meat at different concentrations ranged from 81 to 129% with relative standard deviation below 27%. The corresponding results from the fat ranged from 70 to 123% with relative standard deviation below 25%. The methods showed sensitivity, precision, and accuracy according to EPA standards and quantification limits below the maximum residue limit established by European Union, except for chlorfenvinphos in the fat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cefadroxil is a semi-synthetic first-generation oral cephalosporin used in the treatment of mild to moderate infections of the respiratory and urinary tracts, skin and soft tissue infections. In this work a simple, rapid, economic and sensitive HPLC-UV method is described for the quantitative determination of cefadroxil in human plasma samples using lamivudine as internal standard. Sample pre-treatment was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed with a mobile phase consisting of a mixture of sodium dihydrogen phosphate monohydrate solution, methanol and acetonitrile in the ratio of 90:8:2 (v/v/v) at a flow rate of 1.0mL/min. The proposed method is linear between 0.4 to 40.0 mu g/mL and its average recovery is 102.21% for cefadroxil and 97.94% for lamivudine. The method is simple, sensitive, reproducible, less time consuming for determination of cefadroxil in human plasma. The method can therefore be recommended for pharmacokinetics studies, including bioavailability and bioequivalence studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY BY MASS SPECTROMETRY OF SOLUTIONS OF [HYDROXY(TOSYLOXY)IODO]BENZENE: PROPOSED DISPROPORTIONATION MECHANISMS. Solutions of [hydroxy(tosyloxy)iodo]benzene (HTIB or Koser's reagent) in acetonitrile were analyzed using high resolution electrospray ionization mass spectrometry (ESI-MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS) under different conditions. Several species were characterized in these analyses. Based on these data, mechanisms were proposed for the disproportionation of the iodine(III) compounds in iodine(V) and iodine(I) species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eight new copper(II) complexes with halo-aspirinate anions have been synthesized: [Cu-2(Fasp)(4)(MeCN)(2)] center dot 2MeCN (1), [Cu-2(Clasp)(4)(MeCN)(2)]center dot 2MeCN (2), [Cu-2(Brasp)(4) (MeCn)(2)] center dot 2MeCn (3), {[Cu-2(Fasp)(4)(Pyrz)] center dot 2MeCN}(n) (4) {[Cu-2(Clasp)(4)(Pyrz)] center dot 2MeCN}(n) (5), [Cu-2(Brasp)(4)(Pyrz)](n) (6), [Cu-2(Clasp)(4)(4,4'-Bipy)](n) (7), and [Cu-2(Brasp)(4)(4,4'-Bipy)](n) (8) (Fasp: fluor-aspirinate; Clasp: chloro-aspirinate; Brasp: bromo-aspirinate; MeCN: acetonitrile; Pyrz: pyrazine; 4,4'-Bipy: 4,4'-bipyridine). The crystal structure of two 2 and 4 have been determined by X-ray diffraction methods. All compounds have been studied employing elemental analysis, IR, and UV-Visible spectroscopic techniques. The results have been compared with previous data reported for complexes with similar structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The topographical character of conical intersections (CIs)-either sloped or peaked-has played a fundamental and important role in the discussion of the efficiency of CIs as photochemical "funnels." Here this perspective is employed in connection with a recent study of a model protonated Schiff base (PSB) cis to trans photoisomerization in solution [Malhado et al., J. Phys. Chem. A 115, 3720 (2011)]. In that study, the calculated reduced photochemical quantum yield for the successful production of trans product versus cis reactant in acetonitrile solvent compared to water was interpreted in terms of a dynamical solvent effect related to the dominance, for the acetonitrile case, of S-1 to S-0 nonadiabatic transitions prior to the reaching the seam of CIs. The solvent influence on the quantum yield is here re-examined in the sloped/peaked CI topographical perspective via conversion of the model's two PSB internal coordinates and a nonequilibrium solvent coordinate into an effective branching space description, which is then used to re-analyze the generalized Langevin equation/surface hopping results. The present study supports the original interpretation and enriches it in terms of topographical detail. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4754505]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solutions of [hydroxy(tosyloxy)iodo]benzene (HTIB or Koser's reagent) in acetonitrile were analyzed using high resolution electrospray ionization mass spectrometry (ESI-MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS) under different conditions. Several species were characterized in these analyses. Based on these data, mechanisms were proposed for the disproportionation of the iodine(III) compounds in iodine(V) and iodine(I) species.