38 resultados para Vapor sample

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate whether there are visual and neurophysical decrements in workers with low exposure to Hg vapor. Methods: Visual fields, contrast sensitivity, color vision, and neuropsychological functions were measured in 10 workers (32.5 +/- 8.5 years) chronically exposed to Hg vapor (4.3 +/- 2.8 years; urinary Hg concentration 22.3 +/- 9.3 mu g/g creatinine). Results: For the worst eyes, we found altered visual field thresholds, lower contrast sensitivity, and color discrimination compared with controls (P < 0.05). There were no significant differences between Hg-exposed subjects and controls on. neuropsychological tests. Nevertheless, duration of exposure was statistically correlated to verbal memory and depression scores. Conclusions: Chronic exposure to Hg vapor at currently accepted safety levels was found to be associated with visual losses but not with neuropsychological dysfunctions in the sample of workers studied. (J Occup Environ Med. 2009,51:1403-1412)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty six bottom sediment samples were collected from the Cananeia estuary in summer and winter of 2005. Multielemental analysis was carried out by instrumental neutron activation analysis. Total mercury was determined by cold vapor atomic absorption. As, Cr, Hg and Zn concentrations were compared to the Canadian oriented values (TEL and PEL). Sample points 4 and 9 presented higher concentration for most elements and As and Cr exceeded the TEL values. Organic matter (>10%) associated with siltic and clay sediments was observed. Climatic conditions, hydrodynamic and biogeochemical processes promote differences in seasonal concentrations of elements at some points, which contribute to special distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Color vision was examined in subjects with long-term occupational exposure to mercury (Hg) vapor. The color vision impairment was assessed by employing a quantitative measure of distortion of individual and group perceptual color spaces. Hg subjects (n = 18; 42.1 +/- 6.5 years old; exposure time = 10.4 +/- 5.0 years; time away from the exposure source = 6.8 +/- 4.6 years) and controls (n = 18; 46.1 +/- 8.4 years old) were examined using two arrangement tests, D-15 and D-15d, in the traditional way, and also in a triadic procedure. From each subject`s `odd-one-out` choices, matrices of inter-cap subjective dissimilarities were derived and processed by non-metric multidimensional scaling (MDS). D-15d results differed significantly between the Hg-group and the control group (p < 0.05), with the impairment predominantly along the tritan axis. 2D perceptual color spaces, individual and group, were reconstructed, with the dimensions interpreted as the red-green (RG) and the blue-yellow (BY) systems. When color configurations from the Hg-group were compared to those of the controls, they presented more fluctuations along both chromatic dimensions, indicating a statistically significant difference along the BY axis. In conclusion, the present findings confirm that color vision impairments persist in subjects that have received long-term occupational exposure to Hg-vapor although, at the time of testing, they were presenting mean urinary concentration within the normal range for non-exposed individuals. Considering the advantages of the triadic procedure in clinical evaluation of acquired color vision deficiencies, further studies should attempt to verify and/or improve its efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This longitudinal study addresses the reversibility of color vision losses in subjects who had been occupationally exposed to mercury vapor. Color discrimination was assessed in 20 Hg-exposed patients (mean age = 42.4 +/- 6.5 years; 6 females and 14 males) with exposure to Hg vapor during 10.5 +/- 5.3 years and away from the work place (relative to 2002) for 6.8 +/- 4.2 years. During the Hg exposure or up to one year after ceasing it, mean urinary Hg concentration was 47 +/- 35.4 mu g/g creatinine. There was no information on Hg urinary concentration at the time of the first tests, in 2002 (Ventura et al., 2005), but at the time of the follow-up tests, in 2005, this value was 1.4 +/- 1.4 mu g/g creatinine for patients compared with 0.5 +/- 0.5 mu g/g creatinine for controls (different group from the one in Ventura et al. (2005)). Color vision was monocularly assessed using the Cambridge Colour Test (CCT). Hg-exposed patients had significantly worse color discrimination (p < 0.02) than controls, as evaluated by the size of MacAdam`s color discrimination ellipses and color discrimination thresholds along protan, deutan, and tritan confusion axes. There were no significant differences between the results of the study in Ventura et al. (2005) and in the present follow-up measurements, in 2005, except for worsening of the tritan thresholds in the best eye in 2005. Both chromatic systems, blue-yellow and red-green, were affected in the first evaluation (Ventura et al., 2005) and remained impaired in the follow-up testing, in 2005. These findings indicate that following a long-term occupational exposure to Hg vapor, even several years away from the source of intoxication, color vision impairment remains irreversible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual field losses associated with mercury (Hg) exposure have only been assessed in patients exposed to methylmercury. Here we evaluate the automated visual field in 35 ex-workers (30 males; 44.20+/-5.92 years) occupationaly exposed to mercury vapor and 34 controls (21 males; 43.29+/-8.33 years). Visual fields were analyzed with the Humphrey Field Analyzer II (model 750i) using two tests: the standard automated perimetry (SAP, white-on-white) and the short wavelength automated perimetry (SWAP, blue-on-yellow) at 76 locations within a 27 degrees central visual field. Results were analyzed as the mean of the sensitivities measured at the fovea, and at five successive concentric rings, of increasing eccentricity, within the central field. Compared to controls, visual field sensitivities of the experimental group measured using SAP were lower for the fovea as well as for all five eccentricity rings (p<0.05). Sensitivities were significantly lower in the SWAP test (p<0.05) for four of the five extra-foveal eccentricity rings; they were not significant for the fovea (p = 0.584) or for the 15 degrees eccentricity ring (p = 0.965). These results suggest a widespread reduction of sensitivity in both visual field tests. Previous reports in the literature describe moderate to severe concentric constriction of the visual field in subjects with methylmercury intoxication measured manually with the Goldman perimeter. The present results amplify concerns regarding potential medical risks of exposure to environmental mercury sources by demonstrating significant and widespread reductions of visual sensitivity using the more reliable automated perimetry. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrast sensitivity (CS) was evaluated in 41 former workers from a lamp manufacturing plant who were on disability retirement due to exposure to mercury and 14 age-matched controls. The CS was measured monocularly using the sweep visual evoked potential (sVEP) paradigm at 6 spatial frequencies (0.2, 0.8, 2.0, 4.0, 15.0, and 30 cpd). Statistical difference (p < 0.05) was found between the controls and the patient right and left eyes for 2.0 and 4.0 cpd. According the results in those spatial frequencies the eyes were classified in best and worst. Statistical differences were found between the controls and the best eyes for 2.0 and 4.0 cpd and for 0.8, 2.0, and 4.0 cpd for their worst eyes. No correlation was found between CS results and the time of exposure (mean 8.9 yr +/- 4.1), time away from the mercury source (mean = 6.0 yr +/- 3.9), urinary mercury level at the time of work (mean = 40.6 mu g/g +/-36.3) or with the mercury level at the CS measurement time (mean = 1.6 mu g/g +/-1.1). We show the first evidence of a permanent impairment in CS measured objectively with the sVEP. Our data complement the previous psychophysical works reporting a diffuse impairment in the CS function showing a CS reduction in the low to middle spatial frequencies. In conclusion, non-reversible CS impairment was found in occupational exposure to mercury vapor. We suggest that CS measurement should be included in studies of the mercury effects of occupational exposure. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies on functional capacity in community-dwelling older people have shown associations between declines in instrumental activities of daily living (IADL) and several factors. Among these, age has been the most consistently related to functional capacity independent of other variables. We aimed at evaluating the performance of a sample of healthy and cognitively intact Brazilian older people on activities of daily living and to analyze its relation to social-demographic variables. Methods: We conducted a secondary analysis of data collected for previous epidemiological studies with community-dwelling subjects aged 60 years or more. We selected subjects who did not have dementia or depression, and with no history of neurological diseases, heart attack, HIV, hepatitis or arthritis (n = 1,111). Functional capacity was assessed using the Brazilian version of the Older American Resources and Services Questionnaire (BOMFAQ). ADL performance was analyzed according to age, gender, education, and marital status (Pearson's chi(2), logistic regression). Results: IADL difficulties were present in our sample, especially in subjects aged 80 years or more, with lower levels of education, or widowed. The logistic regression analysis results indicated that "higher age" and "lower education" (p <= 0.001) remained significantly associated with IADL difficulty. Conclusions: Functional decline was present in older subjects even in the absence of medical conditions and cognitive impairment. Clinicians and researchers could benefit from knowing what to expect from older people regarding IADL performance in the absence of medical conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study the effect of relative humidity (RH) during spin-coating process on the structural characteristics of cellulose acetate (CA), cellulose acetate phthalate (C-A-P), cellulose acetate butyrate (CAB) and carboxymethyl cellulose acetate butyrate (CMCAB) films was investigated by means of atomic force microscopy (AFM), ellipsometry and contact angle measurements. All polymer solutions were prepared in tetrahydrofuran (THF), which is a good solvent for all cellulose esters, and used for spin-coating at RH of (35 +/- A 5)%, (55 +/- A 5)% or (75 +/- A 5)%. The structural features were correlated with the molecular characteristics of each cellulose ester and with the balance between surface energies of water and THF and interface energy between water and THF. CA, CAB, CMCAB and C-A-P films spin-coated at RH of (55 +/- A 5)% were exposed to THF vapor during 3, 6, 9, 60 and 720 min. The structural changes on the cellulose esters films due to THF vapor exposition were monitored by means of AFM and ellipsometry. THF vapor enabled the mobility of cellulose esters chains, causing considerable changes in the film morphology. In the case of CA films, which are thermodynamically unstable, dewetting was observed after 6 min exposure to THF vapor. On the other hand, porous structures observed for C-A-P, CAB and CMCAB turned smooth and homogeneous after only 3 min exposure to THF vapor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-(CD)-D-4) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 x 10(-5) mol As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-(CD)-D-4 and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The water vapor conductance (G(H20)) of the neosauropod eggs from the Lower Cretaceous Sanagasta nesting site in La Rioja Province, Argentina, was examined and compared with other Cretaceous Argentinean oological material. The 2900 mgH(2)O/day.Torr G(H2O) of the Sanagasta eggshells confirms an extremely moist nesting environment and supports field observations of dug-out nests in a geothermal setting. The observed thinning of the outer eggshell surface during incubation increases gas conductance and concomitantly decreases eggshell mechanical resistance during the late ontogenetic stages, thus facilitating embryonic development and hatching. The Sanagasta and Entre Rios Province faveoloolithid eggs display the highest and comparable 61120 values and share several morphological and diagenetic characters, indicating comparable nesting strategy in geothermal settings. However, the faveoloolithid Yamintie and La Pampa Province specimens cluster together with lower G(H20) values closer to the megaloolithid eggs. The Gnu) of the megaloolithid egg Megaloolithus patagonicus was reconsidered and new results are now congruent with other reported megaloolithid GH2O values. Additionally, we hypothesize that V-shaped pore canals of M. patagonicus, which upper sections reach only the top third or half eggshell thickness and, a wider section in the middle would not compromise the overall egg mechanical resistance like vertical pores connecting directly the outer to the inner eggshell surfaces. Such pore spatial arrangement and geometry would enhance, as the eggshell thins during incubation, a greater G(H2O), G(O2) and G(CO2) and facilitate embryonic development in high moisture nesting contents. Overall, data suggests that neosauropod nesting and brooding behaviors were dependent on elevated moisture nesting environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 degrees C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p < 0.001). No differences were found between groups 1 and 2 (p > 0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenia is a severe psychiatric disorder with frequent recurrent psychotic relapses and progressive functional impairment. It results from a poorly understood gene-environment interaction. The gene encoding catechol-O-methyltransferase (COMT) is a likely candidate for schizophrenia. Its rs165599 (A/G) polymorphism has been shown to be associated with alteration of COMT gene expression. Therefore, the present study aimed to investigate a possible association between schizophrenia and this polymorphism. The distribution of the alleles and genotypes of this polymorphism was investigated in a Brazilian sample of 245 patients and 834 controls. The genotypic frequencies were in Hardy-Weinberg equilibrium and no statistically significant differences were found between cases and controls when analyzed according to gender or schizophrenia subtypes. There was also no difference in homozygosis between cases and controls. Thus, in the sample studied, there was no evidence of any association between schizophrenia and rs165599 (A/G) polymorphism in the non-coding region 3' of the COMT gene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complexity in time series is an intriguing feature of living dynamical systems, with potential use for identification of system state. Although various methods have been proposed for measuring physiologic complexity, uncorrelated time series are often assigned high values of complexity, errouneously classifying them as a complex physiological signals. Here, we propose and discuss a method for complex system analysis based on generalized statistical formalism and surrogate time series. Sample entropy (SampEn) was rewritten inspired in Tsallis generalized entropy, as function of q parameter (qSampEn). qSDiff curves were calculated, which consist of differences between original and surrogate series qSampEn. We evaluated qSDiff for 125 real heart rate variability (HRV) dynamics, divided into groups of 70 healthy, 44 congestive heart failure (CHF), and 11 atrial fibrillation (AF) subjects, and for simulated series of stochastic and chaotic process. The evaluations showed that, for nonperiodic signals, qSDiff curves have a maximum point (qSDiff(max)) for q not equal 1. Values of q where the maximum point occurs and where qSDiff is zero were also evaluated. Only qSDiff(max) values were capable of distinguish HRV groups (p-values 5.10 x 10(-3); 1.11 x 10(-7), and 5.50 x 10(-7) for healthy vs. CHF, healthy vs. AF, and CHF vs. AF, respectively), consistently with the concept of physiologic complexity, and suggests a potential use for chaotic system analysis. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4758815]