17 resultados para Trissecção do ângulo

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the frequency of conjunctival HLA-DR expression (a surrogate marker for inflammation) in eyes treated with topical prostaglandin analogues versus eyes treated with other topical antiglaucomatous drugs. METHODS: Patients diagnosed with primary open-angle glaucoma presenting indication for trabeculectomy were divided in groups according to the use or not of prostaglandin analogues. All subjects were treated with the maximum tolerated dose of antiglaucomatous drugs until the date of the surgery. At the beginning of the surgical procedure, a 5 x 5 mm biopsy of the bulbar conjunctiva was collected, incubated with monoclonal anti-HLA-DR antibody and processed for histological analysis. RESULTS: Of the 31 eyes included (31 patients), 25 were under topical prostaglandin analogues (Group 1) and six under other topical pharmacological agents (Group 2). Fourteen eyes of Group 1 (56%) and three of Group 2 (50 %) were positive for the inflammatory marker HLA-DR (P=1.0). The percentage of stained cells ranged from 15.49 to 48.09% (median: 27.61) in Group 1, and from 18.35 to 28 (median: 20.71) in Group 2, with no differences statistically significant (p=0.33). CONCLUSION: The use of prostaglandin analogues did not increase conjunctival expression of HLA-DR compared to other topical antiglaucomatous agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The joint torque is an important variable related to children with cerebral palsy. The present study analyzed kinetic parameters during elbow flexion and extension movements in healthy and cerebral palsy children. Ten healthy and 10 cerebral palsy children participated of the study. An isokinetic dynamometer was used to measure the elbow mean peak torque, mean angle peak torque, coefficient of variation and acceleration during flexion and extension movements at different angular speeds. The mean peak torque on extension movement in healthy children group was significant higher compared to the cerebral palsy group. The coefficient of variation on both flexion and extension movements was significantly higher in cerebral palsy group. However there were significantly difference on both groups compared the lowest and highest velocities. Although the results showed no difference in flexor peak torque, the acceleration is significantly lower in lowest and highest angular velocity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In the literature, there are several experimental models that induce scoliosis in rats; however, they make use of drugs or invasive interventions to generate a scoliotic curve. Objectives: To design and apply a non-invasive immobilization model to induce scoliosis in rats. Methods: Four-week old male Wistar rats (85 +/- 3.3 g) were divided into two groups: control (CG) and scoliosis (SG). The animals in the SG were immobilized by two vests (scapular and pelvic) made from polyvinyl chloride (PVC) and externally attached to each other by a retainer that regulated the scoliosis angle for twelve weeks with left convexity. After immobilization, the abdominal, intercostal, paravertebral, and pectoral muscles were collected for chemical and metabolic analyses. Radiographic reports were performed every 30 days over a 16-week period. Results: The model was effective in the induction of scoliosis, even 30 days after immobilization, with a stable angle of 28 +/- 5 degrees. The chemical and metabolic analyses showed a decrease (p<0.05) in the glycogenic reserves and in the relationship between DNA and total protein reserves of all the muscles analyzed in the scoliosis group, being lower (p<0.05) in the convex side. The values for the Homeostatic Model Assessment of Insulin Resistance indicated a resistance condition to insulin (p<0.05) in the scoliosis group (0.66 +/- 0.03), when compared to the control group (0.81 +/- 0.02). Conclusions: The scoliosis curvature remained stable 30 days after immobilization. The chemical and metabolic analyses suggest changes in muscular homeostasis during the induced scoliosis process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: A biofotogrametria é uma técnica difundida na área da saúde e, apesar dos cuidados metodológicos, há distorções nas leituras angulares das imagens fotográficas. OBJETIVO: Mensurar o erro das medidas angulares em imagens fotográficas com diferentes resoluções digitais em um objeto com ângulos pré-demarcados. MÉTODOS: Utilizou-se uma esfera de borracha com 52 cm de circunferência. O objeto foi previamente demarcado com ângulos de 10º, 30º, 60º e 90º, e os registros fotográficos foram realizados com o eixo focal da câmera a três metros de distância e perpendicular ao objeto, sem utilização de zoom óptico e com resolução de 3, 5 e 10 Megapixels (Mp). Todos os registros fotográficos foram armazenados, e os valores angulares foram analisados por um experimentador previamente treinado, utilizando o programa ImageJ. As aferições das medidas foram realizadas duas vezes, com intervalo de 15 dias entre elas. Posteriormente, foram calculados os valores de acurácia, erro relativo e em graus, precisão e Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: Quando analisado o ângulo de 10º, a média da acurácia das medidas foi maior para os registros com resolução de 3 Mp em relação às resoluções de 5 e 10 Mp. O ICC foi considerado excelente para as três resoluções de imagem analisadas e, em relação aos ângulos analisados nos registros fotográficos, pôde-se verificar maior acurácia, menor erro relativo e em graus e maior precisão para o ângulo de 90º, independentemente da resolução da imagem. CONCLUSÃO: Os registros fotográficos realizados com a resolução de 3 Mp proporcionaram medidas de maiores valores de acurácia e precisão e menores valores de erro, sugerindo ser a resolução mais adequada para gerar imagem de ângulos de 10º e 30º.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The progression of diabetes and the challenge of daily tasks may result in changes in biomechanical strategies. Descending stairs is a common task that patients have to deal with, however it still has not been properly studied in this population. Objectives: We describe and compare the net joint moments and kinematics of the lower limbs in diabetic individuals with and without peripheral neuropathy and healthy controls during stair descent. Method: Forty-two adults were assessed: control group (13), diabetic group (14), and neuropathic diabetic group (15). The flexor and extensor net moment peaks and joint angles of the hip, knee, and ankle were described and compared in terms of effect size and ANOVAs (p<0.05). Results: Both diabetic groups presented greater dorsiflexion [large effect size] and a smaller hip extensor moment [large effect size] in the weight acceptance phase. In the propulsion phase, diabetics with and without neuropathy showed a greater hip flexor moment [large effect size] and smaller ankle extension [large effect size]. Conclusion: Diabetic patients, even without neuropathy, revealed poor eccentric control in the weight acceptance phase, and in the propulsion phase, they showed a different hip strategy, where they chose to take the leg off the ground using more flexion torque at the hip instead of using a proper ankle extension function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Styloid syndrome is characterized by an elongated styloid process or calcification of the stylomandibular and stylohyoid ligament. This study describes a case of a 65-year-old woman who presented to the Stomatology Clinic, University of Marilia with temporomandibular joint pain, ear ringing and a reduced ability to open the mouth. Panoramic and posteroanterior digital radiographs showed bilateral elongation of the styloid processes, especially of the right side, whose length extended beyond the mandible angle. The diagnosis was confirmed with the association of clinical data and image examinations. The treatment options for styloid Syndrome include clinical follow-up, surgical removal of the styloid process or fracture of the elongated process. The case was managed by providing prosthetic rehabilitation and clinical follow-up, observing the level of discomfort and the benefit that could be achieved by the therapy, and avoiding surgical intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi comparar duas sequências diferentes na rapidez e segurança no preparo de canais curvos simulados. Foram empregados 30 blocos de acrílico com canais simulados que foram divididos em Grupo 1 – La Axxess 20 e 35/.06 25/.06, 20/.06, 25/.04 e 20/.04 e Grupo 2 – K3 Universal (VTVT) – 25/.10, 25/.08, 35/.06, 30/.04, 25/.06 e 20/.04. No preparo de todos os blocos empregou-se a velocidade de 250 rpm e torque de 1.4N/cm. Foram confeccionados dois pontos externos de amálgama para mensuração do desvio e adotou-se 17 mm como comprimento de trabalho. No Grupo 1, dilatou-se até o instrumento 25/.04, enquanto que no Grupo 2 até o 25/.06, e cronometrou-se o tempo de preparo de cada bloco. Na análise do desvio, radiografias com lima k 15 (antes) e K 25 (depois) foram realizadas e digitalizadas, medindo-se o ângulo antes e depois no programa Digora for Windows 1.51. Os dados foram comparados pelo teste T-Student e Mann-Whitney. Os resultados mostraram que em ambas as técnicas não ocorreram diferenças significantes entre o ângulo antes e depois e que não ocorreu diferença significante entre os desvios médios do Grupo 1 (0,130) e do Grupo 2 (1,330). No tempo de preparo, o Grupo 1 foi significantemente mais rápido que o Grupo 2. No Grupo 1, ocorreu a fratura de 1 instrumento, enquanto que no Grupo 2 ocorrerem duas fraturas. Concluiu-se que ambas as técnicas são seguras para o preparo de canais simulados curvos, sendo que no Grupo 1 o tempo de preparo é menor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXT: Failure of a colorectal anastomosis represents a life-threatening complication of colorectal surgery. Splenic flexure mobilization may contribute to reduce the occurrence of anastomotic complications due to technical flaws. There are no published reports measuring the impact of splenic flexure mobilization on the length of mobilized colon viable to construct a safe colorectal anastomosis. OBJECTIVE: The aim of the present study was to determine the effect of two techniques for splenic flexure mobilization on colon lengthening during open left-sided colon surgery using a cadaver model. DESIGN: Anatomical dissections for left colectomy and colorectal anastomosis at the sacral promontory level were conducted in 20 fresh cadavers by the same team of four surgeons. The effect of partial and full splenic flexure mobilization on the extent of mobilized left colon segment was determined. SETTING: University of Sao Paulo Medical School, Sao Paulo, SP, Brazil. Tertiary medical institution and university hospital. PARTICIPANTS: A team of four surgeons operated on 20 fresh cadavers. RESULTS: The length of resected left colon enabling a tension-free colorectal anastomosis at the level of sacral promontory achieved without mobilizing the splenic flexure was 46.3 (35-81) cm. After partial mobilization of the splenic flexure, an additionally mobilized colon segment measuring 10.7 (2-30) cm was obtained. After full mobilization of the distal transverse colon, a mean 28.3 (10-65) cm segment was achieved. CONCLUSION: Splenic flexure mobilization techniques are associated to effective left colon lengthening for colorectal anastomosis. This result may contribute to decision-making during rectal surgery and low colorectal and coloanal anastomosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Apresentar um dispositivo biomecânico para o estudo da reconstrução do ligamento patelofemoral medial (LPFM) e sua isometricidade. MÉTODOS: Foi desenvolvido um sistema biomecânico acessível, que permite a aplicação de forças fisiológicas e não fisiológicas no joelho, através de um braço mecânico e aplicação de pesos e contrapesos, possibilitando a execução de diferentes estudos, além de ter um sistema de medidas bastante preciso de aferição de distâncias entre diferentes estruturas para análise dos experimentos. Este artigo descreve a montagem deste sistema, além de sugerir algumas aplicações práticas. Foram estudados seis joelhos de cadáveres. Os joelhos foram preparados em uma máquina de ensaios desenvolvida no Laboratório de Biomecânica do IOT HC FMUSP, que permitiu a avaliação dinâmica do comportamento patelar, quantificando a sua lateralização entre 0 e 120 graus. A diferença entre as distâncias encontradas, com e sem carga, aplicada na patela foram agrupadas segundo o ângulo de fixação do enxerto (0°, 30°, 60° e 90°) e situação do joelho (íntegro, reconstruído e lesado). RESULTADOS: Houve uma tendência em ocorrer menor desvio lateral em ângulos de fixação acima de 30 graus de flexão, principalmente entre os ângulos entre 45° e 60° graus de flexão, após a reconstrução. Para os demais ângulos não houve significância estatística. CONCLUSÃO: O método desenvolvido é uma ferramenta útil para os estudos da articulação patelofemoral, além de ter um sistema de medidas bastante preciso de aferição de distâncias entre diferentes estruturas e permitir a sua utilização em instituições com menos recursos disponíveis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O comportamento de espalhamento de quatro escórias sintéticas foi investigado pelo método da gota séssil, quando em contato com a matriz de um concreto refratário contendo alto teor de carbono e carbeto de boro como agente antioxidante. A evolução do molhamento do sólido foi monitorada a 1450, 1550 e 1650 ºC por 1800 s. Além disso, simulações termodinâmicas foram efetuadas, usando o programa FactSage®, visando promover um maior entendimento das reações químicas que podem ocorrer na interface dos materiais avaliados. Foi observado que a composição química do líquido afetou diretamente o espalhamento deste e quanto maior o teor de MgO na composição da escória, maiores foram os valores do ângulo de contato entre líquido e sólido. No entanto, em altas temperaturas e tempos prolongados, foram verificadas a formação de bolhas na superfície do líquido e a infiltração das escórias nos poros do refratário. Estes fatores afetaram negativamente e tornaram menos conclusivos os dados coletados nos ensaios propostos, apontando que ainda são necessários aperfeiçoamentos da técnica de molhabilidade para a avaliação de materiais complexos, tais como os concretos refratários.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a confiabilidade intra e interexaminadores e a reprodutibilidade da goniometria em relação à fotogrametria na mão, comparando os ângulos da abdução de polegar, flexão da AIFP do II dedo e flexão da AMCF do V dedo. MÉTODOS: PARTIciparam deste estudo 30voluntários foram divididos em 3 grupos, um grupo de 10 estudantes de Fisioterapia, outro por 10 fisioterapeutas e o terceiro com 10 terapeutas da mão. Cada avaliador realizou as medidas no mesmo molde de mão, utilizando o goniômetro e em seguidadois softwares de fotogrametria, o CorelDraw® e o ALCimagem®. RESULTADOS: Os resultados revelaram que os grupos e os métodos propostos apresentam confiabilidade interexaminadores no geral classificada como excelente (ICC 0,998 I.C. 95% 0,995 - 0,999). Na avaliação intraexaminadores, foi encontrado excelente nível de confiabilidade entre os três grupos. Na comparação entre os grupos para cada ângulo e cada método, observou-se que não houve diferença significativa entre os grupos para a maioria das medidas. CONCLUSÃO: A goniometria e a fotogrametria são métodos confiáveis e reprodutíveis para avaliação de medidas na mão. Porém, pela escassez de referências semelhantes, necessita-se de estudos aprofundados para definição de parâmetros de normalidade entre os métodos nas articulações da mão. Nível de Evidência II, Estudo Diagnóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: A análise morfológica da estrutura óssea de C2, em pacientes com artrite reumatoide, com o objetivo de aumentar a segurança de procedimentos de estabilização desta vértebra. MÉTODOS: Analisamos retrospectivamente 20 tomografias de coluna cervical realizadas em pacientes com artrite reumatoide, foram medidos os seguintes parâmetros: o ângulo espinolaminar, espessura e comprimento da lâmina de C2. RESULTADOS: Os valores médios encontrados são: espessura das lâminas direita 5,92mm e esquerda 5,87mm; comprimento das lâminas direita 27,75mm e esquerda 27,94mm e ângulo espinolaminar 44,7(0). CONCLUSÃO: Os valores obtidos são compatíveis com os de estudos realizados em indivíduos normais publicados por outros autores, não havendo aparente necessidade de alteração na técnica para colocação dos parafusos. Nível de Evidência IV, Série de casos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a posição das estruturas anatômicas em risco durante a inserção de parafusos pediculares na coluna torácica e sua relação com a variação do ângulo de Cobb. MÉTODOS: Os parâmetros estudados foram: a medida do ângulo de Cobb nas radiografias e a posição da medula espinhal, da cavidade pleural e aorta na ressonância nuclear magnética em relação a uma linha de 40mm criada para simular o parafuso pedicular nas cinco vértebras apicais. RESULTADOS: A distância da aorta ao corpo vertebral e o ângulo de segurança do lado convexo apresentaram diferença estatística quando relacionados com a variação do ângulo de Cobb medido. CONCLUSÃO: Os resultados apresentados sugerem maior risco de lesão da artéria aorta com o aumento do ângulo de Cobb e aumento do risco na inserção de parafusos pediculares no lado convexo da curvatura, quando se considera o ângulo de segurança.