12 resultados para Toric implantable collamer lens

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ADOLESCENCE AND DRUG USE THROUGH THE LENS OF PSYCHOANALYSIS: SUFFERING AND ECSTASY IN THE PASSAGE The purpose of this study is to reflect upon the psychological factors of adolescent drug addiction according to a psychoanalytic perspective. First we consider adolescence as a social-historical category and then we discuss the psychoanalytic understanding of the adolescent transition. This theoretical path builds the approach that considers drug use as a phenomenon that serves as a passage ritual to contemporary adolescence. This phenomenon is modulated by the drive organization, which determines how the individual will take ownership of the use of psychoactive substances. We conclude that the substance use may function as a buffer-object, activated to deal with the structural fragility of the contemporary affective bonds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To compare the dynamic viscosity (DV) of superficial layer of temporalis fascia (SLTF) with that of other biological tissues traditionally used for vocal fold implants to treat vocal fold rigidity. Study Design. Experimental. Method. Measurement of DV of samples of SLTF, deep layer of temporalis fascia (DLTF), and abdominal fat of 12 cadavers. Results. DV values of the different samples were presented in the following increasing order: SLTF, DLTF, and abdominal fat. There was statistical difference between the samples. Conclusion. DV of SLTF is lower than of other tissues tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Handling Totally Implantable Access Ports (TIAP) is a nursing procedure that requires skill and knowledge to avoid adverse events. No studies addressing this procedure with undergraduate students were identified prior to this study. Communication technologies, such as videos, have been increasingly adopted in the teaching of nursing and have contributed to the acquisition of competencies for clinical performance. Objective: To evaluate the effect of a video on the puncture and heparinization of TIAP in the development of cognitive and technical competencies of undergraduate nursing students. Method: Quasi-experimental study with a pretest-posttest design. Results: 24 individuals participated in the study. Anxiety scores were kept at levels 1 and 2 in the pretest and posttest. In relation to cognitive knowledge concerning the procedure, the proportion of correct answers in the pretest was 0.14 (SD=0.12) and 0.90 in the posttest (SD=0.05). After watching the video, the average score obtained by the participants in the mock session was 27.20. Conclusion: The use of an educational video with a simulation of puncture and heparinization of TIAP proved to be a strategy that increased both cognitive and technical knowledge. This strategy is viable in the teaching-learning process and is useful as a support tool for professors and for the development of undergraduate nursing students. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing the efficacy of implantable cardioverter-defibrillators (ICD) in patients with Chagas' heart disease (ChHD) and identifying the clinical predictors of mortality and ICD shock during long-term follow-up. ChHD is associated with ventricular tachyarrhythmias and an increased risk of sudden cardiac death. Although ChHD is a common form of cardiomyopathy in Latin American ICD users, little is known about its efficacy in the treatment of this population. The study cohort included 116 consecutive patients with ChHD and an ICD implanted for secondary prevention. Of the 116 patients, 83 (72%) were men; the mean age was 54 +/- 10.7 years. Several clinical variables were tested in a multivariate Cox model for predicting long-term mortality. The average follow-up was 45 +/- 32 months. New York Heart Association class I-II developed in 83% of patients. The mean left ventricular ejection fraction was 42 +/- 16% at implantation. Of the 116 patients, 58 (50%) had appropriate shocks and 13 (11%) had inappropriate therapy. A total of 31 patients died (7.1% annual mortality rate). New York Heart Association class III (hazard ratio [HR] 3.09, 95% confidence interval 1.37 to 6.96, p = 0.0064) was a predictor of a worse prognosis. The left ventricular ejection fraction (HR 0.972, 95% confidence interval 0.94 to 0.99, p = 0.0442) and low cumulative right ventricular pacing (HR 0.23, 95% confidence interval 0.11 to 0.49, p = 0.0001) were predictors of better survival. The left ventricular diastolic diameter was an independent predictor of appropriate shock (I-ER 1.032, 95% confidence interval 1.004 to 1.060, p = 0.025). In conclusion, in a long-term follow-up, ICD efficacy for secondary sudden cardiac death prevention in patients with ChHD was marked by a favorable annual rate of all-cause mortality (7.1%); 50% of the cohort received appropriate shock therapy. New York Heart Association class III and left ventricular ejection fraction were independent predictors of worse prognosis, and low cumulative right ventricular pacing defined better survival. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110:1040-1045)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present effective-mass calculations of the bound-state energy levels of electrons confined inside lens-shaped InxGa1-xAs quantum dots (QDs) embedded in a GaAs matrix, taking into account the strain as well as the In gradient inside the QDs due to the strong In segregation and In-Ga intermixing present in the InxGa1-xAs/GaAs system. In order to perform the calculations, we used a continuum model for the strain, and the QDs and wetting layer were divided into their constituting monolayers, each one with a different In concentration, to be able to produce a specific composition profile. Our results clearly show that the introduction of such effects is very important if one desires to correctly reproduce or predict the optoelectronic properties of these nanostructures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erbium doped tellurite glasses (TeO2 + Li2O + TiO2) were prepared by conventional melt-quenching method to study the influence of the Er3+ concentration on the luminescence quantum efficiency (η) at 1.5 µm. Absorption and luminescence data were used to characterize the samples, and the η parameter was measured using the well-known thermal lens spectroscopy. For low Er3+ concentration, the measured values are around 76%, and the concentration behavior of η shows Er-Er and Er-OH- interactions, which agreed with the measured lifetime values.