15 resultados para Static Synchronous Compensators (STATCOM)

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design and implementation of a new control scheme for reactive power compensation, voltage regulation and transient stability enhancement for wind turbines equipped with fixed-speed induction generators (IGs) in large interconnected power systems is presented in this study. The low-voltage-ride-through (LVRT) capability is provided by extending the range of the operation of the controlled system to include typical post-fault conditions. A systematic procedure is proposed to design decentralised multi-variable controllers for large interconnected power systems using the linear quadratic (LQ) output-feedback control design method and the controller design procedure is formulated as an optimisation problem involving rank-constrained linear matrix inequality (LMI). In this study, it is shown that a static synchronous compensator (STATCOM) with energy storage system (ESS), controlled via robust control technique, is an effective device for improving the LVRT capability of fixed-speed wind turbines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental platform that allows application of internal faults on the armature windings of a specially modified synchronous generator in a controlled environment is described. It allows recording and studying current and voltage waveforms of internal fault conditions that may occur in a synchronous generator. Thus, traditional and new protection functions can be tested by using real data, and the transient response of the machine due to internal faults can be analyzed more closely. The hardware-software platform is described in detail, as well as all its control functions. The results can contribute significantly in new protection developments, as well as for educational purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barroso, R, Tricoli, V, dos Santos Gil, S, Ugrinowitsch, C, and Roschel, H. Maximal strength, number of repetitions, and total volume are differently affected by static-, ballistic-, and proprioceptive neuromuscular facilitation stretching. J Strength Cond Res 26(9): 2432-2437, 2012-Stretching exercises have been traditionally incorporated into warm-up routines before training sessions and sport events. However, the effects of stretching on maximal strength and strength endurance performance seem to depend on the type of stretching employed. The objective of this study was to compare the effects of static stretching (SS), ballistic stretching (BS), and proprioceptive neuromuscular facilitation (PNF) stretching on maximal strength, number of repetitions at a submaximal load, and total volume (i.e., number of repetitions 3 external load) in a multiple-set resistance training bout. Twelve strength-trained men (20.4 +/- 4.5 years, 67.9 +/- 6.3 kg, 173.3 +/- 8.5 cm) volunteered to participate in this study. All of the subjects completed 8 experimental sessions. Four experimental sessions were designed to test maximal strength in the leg press (i.e., 1 repetition maximum [1RM]) after each stretching condition (SS, BS, PNF, or no-stretching [NS]). During the other 4 sessions, the number of repetitions performed at 80% 1RM was assessed after each stretching condition. All of the stretching protocols significantly improved the range of motion in the sit-and-reach test when compared with NS. Further, PNF induced greater changes in the sit-and-reach test than BS did (4.7 +/- 1.6, 2.9 +/- 1.5, and 1.9 +/- 1.4 cm for PNF, SS, and BS, respectively). Leg press 1RM values were decreased only after the PNF condition (5.5%, p < 0.001). All the stretching protocols significantly reduced the number of repetitions (SS: 20.8%, p < 0.001; BS: 17.8%, p = 0.01; PNF: 22.7%, p < 0.001) and total volume (SS: 20.4%, p < 0.001; BS: 17.9%, p = 0.01; PNF: 22.4%, p < 0.001) when compared with NS. The results from this study suggest that, to avoid a decrease in both the number of repetitions and total volume, stretching exercises should not be performed before a resistance training session. Additionally, strength-trained individuals may experience reduced maximal dynamic strength after PNF stretching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We find the first nonlinear correction to the field produced by a static charge at rest in a background constant magnetic field. It is quadratic in the charge and purely magnetic. The third-rank polarization tensor-the nonlinear response function-is written within the local approximation of the effective action in an otherwise model-and approximation-independent way within any P-invariant nonlinear electrodynamics, QED included. DOI: 10.1103/PhysRevD.86.125028

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of subjective time have adopted different methods to understand different processes of time perception. Four sculptures, with implied movement ranked as 1.5-, 3.0-, 4.5-, and 6.0-point stimuli on the Body Movement Ranking Scale, were randomly presented to 42 university students untrained in visual arts and ballet. Participants were allowed to observe the images for any length of time (exploration time) and, immediately after each image was observed, recorded the duration as they perceived it. The results of temporal ratio (exploration time/time estimation) showed that exploration time of images also affected perception of time, i.e., the subjective time for sculptures representing implied movement were overestimated.\

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cornachione AS, Rassier DE. A non-cross-bridge, static tension is present in permeabilized skeletal muscle fibers after active force inhibition or actin extraction. Am J Physiol Cell Physiol 302: C566-C574, 2012. First published November 16, 2011; doi: 10.1152/ajpcell.00355.2011.-When activated muscle fibers are stretched, there is a long-lasting increase in the force. This phenomenon, referred to as "residual force enhancement," has characteristics similar to those of the " static tension," a long-lasting increase in force observed when muscles are stretched in the presence of Ca2+ but in the absence of myosin-actin interaction. Independent studies have suggested that these two phenomena have a common mechanism and are caused either by 1) a Ca2+-induced stiffening of titin or by 2) promoting titin binding to actin. In this study, we performed two sets of experiments in which activated fibers (pCa(2+) 4.5) treated with the myosin inhibitor blebbistatin were stretched from 2.7 to 2.8 mu m at a speed of 40 L-o/s, first, after partial extraction of TnC, which inhibits myosin-actin interactions, or, second, after treatment with gelsolin, which leads to the depletion of thin (actin) filaments. We observed that the static tension, directly related with the residual force enhancement, was not changed after treatments that inhibit myosin-actin interactions or that deplete fibers from troponin C and actin filaments. The results suggest that the residual force enhancement is caused by a stiffening of titin upon muscle activation but not with titin binding to actin. This finding indicates the existence of a Ca2+-regulated, titin-based stiffness in skeletal muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for electromagnetic torque ripple and copper losses reduction in (non-sinusoidal or trapezoidal) surface-mount permanent magnet synchronous machines (SM-PMSM). The method is based on an extension of classical dq transformation that makes it possible to write a vectorial model for this kind of machine (with a non-sinusoidal back-EMF waveform). This model is obtained by the application of that transformation in the classical machine per-phase model. That transformation can be applied to machines that have any type of back-EMF waveform, and not only trapezoidal or square-wave back-EMF waveforms. Implementation results are shown for an electrical converter, using the proposed vectorial model, feeding a non-sinusoidal synchronous machine (brushless DC motor). They show that the use of this vectorial mode is a way to achieve improvements in the performance of this kind of machine, considering the electromagnetic torque ripple and copper losses, if compared to a drive system that employs a classical six-step mode as a converter. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Cardiac surgery (CC) determines systemic and pulmonary changes that require special care. What motivated several studies conducted in healthy subjects to assess muscle strength were the awareness of the importance of respiratory muscle dysfunction in the development of respiratory failure. These studies used maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) values. This study examined the concordance between the values predicted by the equations proposed by Black & Hyatt and Neder, and the measured values in cardiac surgery (CS) patients. Methods: Data were collected from preoperative evaluation forms. The Lin coefficient and Bland-Altman plots were used for statistical concordance analysis. The multiple linear regression and analysis of variance (ANOVA) were used to produce new formulas. Results: There were weak correlations of 0.22 and 0.19 in the MIP analysis and of 0.10 and 0.32 in the MEP analysis, for the formulas of Black & Hyatt and Neder, respectively. The ANOVA for both MIP and MEP were significant (P <0.0001), and the following formulas were developed: MIP = 88.82 - (0.51 x age) + (19.86 x gender), and MEP = 91.36 -(030 x age) + (29.92 x gender). Conclusions: The Black and Hyatt and Neder formulas predict highly discrepant values of MIP and MEP and should not be used to identify muscle weakness in CS patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of the obesity and handgrip strength on the static balance of active older women in the opened and closed eyes conditions. Thirty one women aged from 65 to 75 years (16 eutrophic and 15 obese) were evaluated. Mean age and BMI of the eutrophic women were, respectively, 68.3 +/- 2.7 years and 23.4 +/- 1.6kg/m(2), and of the obese women were 69.1 +/- 2.7 years and 33.5 +/- 3kg/m(2). Handgrip strength was evaluated using a dynamometer (JAMAR). A tridimensional sensors system was used to evaluate the static postural balance. The tests were performed for 90 seconds, with eyes opened and closed. The mean handgrip strength of the eutrophic women was 25.1 +/- 4.6kgf and of the obese women was 24.8 +/- 5.2kgf, (p>0,05). Significant differences between groups were only observed in the maximum displacement with opened eyes (p=0,04) and closed eyes(p<0,01). There was no correlation between the maximum displacement neither with the BMI or the handgrip strength. The present study showed smaller a-p displacement in obese than in eutrophic women, with major statistic difference in the eyes closed condition. In the present study, the handgrip strength did not influence the static balance, however the obesity was a determinant factor for the smaller a-p displacement of the active older women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We prove that the hard thermal loop contribution to static thermal amplitudes can be obtained by setting all the external four-momenta to zero before performing the Matsubara sums and loop integrals. At the one-loop order we do an iterative procedure for all the one-particle irreducible one-loop diagrams, and at the two-loop order we consider the self-energy. Our approach is sufficiently general to the extent that it includes theories with any kind of interaction vertices, such as gravity in the weak field approximation, for d space-time dimensions. This result is valid whenever the external fields are all bosonic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vestibular-ocular reflex assessment is important, but not enough. Tridimensional electromagnetic sensor systems represent a new method to assess posturography. Aim: To assess body sway in healthy subjects who had positive Dix Hallpike and Epley maneuvers and with other vestibular dysfunctions by means of a three-dimensional system. Study design: Prospective. Materials and Methods: We had 23 healthy women, 15 with peripheral vestibular dysfunction found upon caloric test and 10 with positive Epley and Dix Hallpike maneuvers. All tests performed in the following positions: open and closed eyes on stable and unstable surfaces. Results: With the Eyes Open and on a stable surface, p < 0.01 between the control group and the one with peripheral vestibular dysfunction in all variables, except the a-p maximum, full speed and mediolateral trajectory velocity, which had a p < 0.01 between the group with vestibular dysfunction and controls in all positions. The group with positive Epley and Dix Hallpike maneuvers had p < 0.01 at full speed and in its components in the x and y in positions with open and eyes closed on an unstable surface. Conclusion: The tridimensional electromagnetic sensors system was able to generate reliable information about body sway in the study volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compute the effective Lagrangian of static gravitational fields interacting with thermal fields. Our approach employs the usual imaginary time formalism as well as the equivalence between the static and space-time independent external gravitational fields. This allows to obtain a closed form expression for the thermal effective Lagrangian in d space-time dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues. Thus, there are several anti-islanding techniques; however, most of them present technical limitations so that they are likely to fail in certain situations. Therefore, it is important to quantify and determine whether the scheme under study is adequate or not. In this context, this paper proposes an index to evaluate the effectiveness of anti-islanding frequency-based relays commonly used to protect synchronous distributed generators. The method is based on the calculation of a numerical index that indicates the time period that the system is unprotected against islanding considering the global period of analysis. Although this index can precisely be calculated based on several electromagnetic transient simulations, a practical method is also proposed to calculate it directly from simple analytical formulas or lookup tables. The results have shown that the proposed approach can assist distribution engineers to assess and set anti-islanding protection schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design: Cross-sectional study. Objectives: To evaluate the efficacy of the Postural Assessment Software PAS/SAPO in the posture analysis of individuals with spinal cord injury (SCI) during sitting position and to analyze if the use of different types of seat cushions-gel and foam, with no cushion-can interfere in the individual's posture during sitting position. Setting: Centre of Rehabilitation at the University Hospital (FMRP-USP), Ribeirao Preto, Brazil. Methods: Eight individuals, four paraplegics and four tetraplegics with SCI and 20 healthy individuals participated in the study. Photos were taken of individuals in the sitting position using foam, gel cushions and with no cushion. They were analyzed using the PAS/SAPO. The alignment of the anterior-superior iliac spine (ASIS) and the posterior pelvic tilt were evaluated from the angle formed between the ASIS and the greater trochanter of the femur. Results: The group of healthy individuals presented the best postural alignment when compared with the group with SCI, both for the ASIS alignment (P < 0.05) and for the degree of posterior pelvic tilt (P < 0.05). No significant differences were found in the variables analyzed when the seat cushions were compared. Conclusion: The different types of cushions did not alter the sitting posture; however, individuals with SCI showed worse postural alignment than the healthy individuals. PAS/SAPO was demonstrated to be useful for postural assessment. Spinal Cord (2012) 50, 627-631; doi:10.1038/sc.2012.7; published online 21 February 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate the association between the patellofemoral pain syndrome and the clinical static measurements: the rearfoot and the Q angles. The design was a cross-sectional, observational, case-control study. We evaluated 77 adults (both genders), 30 participants with patellofemoral pain syndrome, and 47 controls. We measured the rearfoot and Q angles by photogrammetry. Independent t-tests were used to compare outcome continuous measures between groups. Outcome continuous data were also transformed into categorical clinical classifications, in order to verify their statistical association with the dysfunction, and χ2 tests for multiple responses were used. There were no differences between groups for rearfoot angle [mean differences: 0.2º (95%CI -1.4-1.8)] and Q angle [mean differences: -0.3º (95%CI -3.0-2.4). No associations were found between increased rearfoot valgus [Odds Ratio: 1.29 (95%CI 0.51-3.25)], as well as increased Q angle [Odds Ratio: 0.77 (95%CI 0.31-1.93)] and the patellofemoral pain syndrome occurrence. Although widely used in clinical practice and theoretically thought, it cannot be affirmed that increased rearfoot valgus and increased Q angle, when statically measured in relaxed stance, are associated with patellofemoral pain syndrome (PFPS). These measures may have limited applicability in screening of the PFPS development.