10 resultados para Soot volume fraction

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present work we revisit the size data of CdS microcrystals previously collected in the glassy matrix of Germanium oxide. The CdS clusters analyzed using electron microscopy images have shown a wurtzite structure. The mean average radius, dispersion and volume evaluated from the histograms showed good agreement for t(1/3), t(2/3) and t laws, respectively. We observed that the amount of microcrystals remains constant throughout the heat treatment process, as well as that the radii distribution has a lower limit and increases with heat treatment. The distribution of radii follows a distribution similar to the Lifshitz-Slyozov-Wagner distribution limited in the origin. Discussions led to the conclusion that the growth of CdS is a process that occurs after the fluctuating nucleation and coalescence phases. We then analyze the growth process, assuming that the evaporation is overcome by the precipitation rate, stabilizing all clusters with respect to dissolution back into the matrix. The problem was simplified neglecting anisotropy and the assuming a spherical shape for clusters and particles. The low interface tension was described in terms of an empirical potential barrier in the surface of the cluster. The growth dynamics developed considering that the number of clusters remains constant, and that the minimum size of these clusters grow with time, as the first order approximation showed a good agreement with the flaw. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oxide-dispersion-strengthened (ODS) ferritic-martensitic steels are candidates for applications in fusion power plants where micro structural long-term stability at temperatures of 650 degrees C to 700 degrees C are required. The microstructural stability of 80% cold-rolled reduced-activation ferritic-martensitic 9% Cr ODS-Eurofer steel was investigated within a wide range of temperatures (300 degrees C to 1350 degrees C). Fine oxide dispersion is very effective to prevent recrystallization in the ferritic phase field. The low recrystallized volume fraction (<0.1) found in samples annealed at 800 degrees C is associated with the nuclei found at prior grain boundaries and around coarse M23C6 particles. The combination of retarding effects such as Zener drag and concurrent recovery decrease the local stored energy and impede further growth of the recrystallization nuclei. Above 90 degrees C, martensitic transformation takes place with consequent coarsening. Significant changes in crystallographic texture are also reported.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is reported superconductivity in Nb5Ge3C0.3, an interstitial carbide compound. The temperature dependence of the electrical resistivity, ac-susceptibility, and heat capacity (HC) indicate that a bulk type-II superconductivity appears at T-C - 15.3 K. Magneto-resistance measurements suggest an upper critical field of B-C2 similar to 10.6 T and a coherence length of xi similar to 55 angstrom at zero temperature. Neutron diffraction analyzes locate the carbon atoms at the interstitial 2b site of the Mn5Si3 type-structure. Heat capacity data below T-C are well described by BCS theory. The size of the jump at T-C is in good agreement with the superconducting volume fraction observed in susceptibility measurements. A Debye temperature and Sommerfeld constant were also extracted from heat capacity data as 343 K and 34 mJ/mol K-2, respectively. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4730611]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The hallmark of Chagas disease (CD) is multifocal myocarditis and extensive fibrosis. We investigated the potential effect of colchicine on myocardial remodeling in experimental CD. Methods and Results: One hundred Syrian hamsters were randomly divided into noninfected untreated control (CG), noninfected control treated with colchicine (COLG 0.4 mg kg(-1) d(-1) by gavage), infected (IG), and infected treated with colchicine (ICOLG, 0.4 mg kg(-1) d(-1)) groups. The interstitial collagen volume fraction (ICVF) was evaluated by videomorphometry with picrosirius red staining. The gelatinolytic activities of matrix metalloproteinase (MMP) 2 were examined with the use of zymography. Myocarditis was described according to the Dallas criteria. Statistical comparisons were performed with parametric analysis of variance and Tukey test. ICVF (%) accumulation was attenuated in infected colchicine-treated animals in the left (CG 0.81 +/- 0.13, COLG 0.85 +/- 0.13, IG: 1.35 +/- 0.31,* ICOLG 1.06 +/- 0.19; *P < .05 compared with ICOLG) and right ventricles (CG 1.4 +/- 0.36, COLG 1.26 +/- 0.14, IG 1.97 +/- 0.058,* ICOLG: 1.52 +/- 0.23; *P < .05 compared with ICOLG). A significant increase in MMP-2 enzymatic activity (UA) was observed in ICOLG (17,432.8*) compared with GC (3731.6), COLG (2,792.6), and IG (4,286.3; *P < .001). In IG, 66% of animals had myocarditis compared with only 49% in ICOLG. Conclusions: Colchicine had a protective effect on myocardium, indicated by decreased interstitial myocardial fibrosis, increased intensity of MMP-2, and attenuated myocardial inflammation. (J Cardiac Fail 2012;18:654-659)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Walking with high-heeled shoes is a common cause of venous complaints such as pain, fatigue, and heavy-feeling legs. The aim of the study was to clarify the influence of high-heeled shoes on the venous return and test the hypothesis that women wearing different styles of high-heeled shoes present an impaired venous return when compared with their values when they are barefoot. Methods: Thirty asymptomatic women (mean age, 26.4 years) wearing appropriately sized shoes were evaluated by air plethysmography (APG), a test that measures changes in air volume on a cuff placed on the calf, while they performed orthostatic flexion and extension foot movements and altered standing up and lying down. The test was repeated in four situations: barefoot (0 cm), medium heels (3.5 cm), stiletto high heels (7 cm), and platform high heels (7 cm). The APG values of venous filling index (VFI), ejection fraction (EF), and residual volume fraction (RVF) were divided into four groups according to heel height and compared by repeated-measures analysis of variance. Results: RVF was increased in the groups wearing high heels (stiletto and platform) compared with the barefoot group (P < .05). RVF was increased in the medium-heel group (3.5 cm) compared with the barefoot group (P < .05), and despite the lack of statistical significance, the medium-heel group showed lower values of RVF compared with the two high-heel groups. The EF parameter followed the opposite tendency, showing higher values for the barefoot group compared with the other three groups (P < .05). Values for VFI were similar in the three situations evaluated. Conclusions: High heels reduce muscle pump function, as demonstrated by reduced EF and increased RVF values. The continuous use of high heels tends to provoke venous hypertension in the lower limbs and may represent a causal factor of venous disease symptoms. (J Vasc Surg 2012;56:1039-44.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coffee intake has been inversely related to the incidence of liver diseases, although there are controversies on whether these beneficial effects on human health are because of caffeine or other specific components in this popular beverage. Thus, this study evaluated the protective effects of coffee or caffeine intake on liver injury induced by repeated thioacetamide (TAA) administration in male Wistar rats. Rats were randomized into five groups: one untreated group (G1) and four groups (G2G5) treated with the hepatotoxicant TAA (200 similar to mg/kg b.w., i.p.) twice a week for 8 similar to weeks. Concomitantly, rats received tap water (G1 and G2), conventional coffee (G3), decaffeinated coffee (G4) or 0.1% caffeine (G5). After 8 similar to weeks of treatment, rats were killed and blood and liver samples were collected. Conventional and decaffeinated coffee and caffeine intake significantly reduced serum levels of alanine aminotransferase (ALT) (p similar to<similar to 0.001) and oxidized glutathione (p similar to<similar to 0.05), fibrosis/inflammation scores (p similar to<similar to 0.001), collagen volume fraction (p similar to<similar to 0.01) and transforming growth factor beta-1 (TGF-beta 1) protein expression (p similar to=similar to 0.001) in the liver from TAA-treated groups. In addition, conventional coffee and caffeine intake significantly reduced proliferating cellular nuclear antigen (PCNA) S-phase indexes (p similar to<similar to 0.001), but only conventional coffee reduced cleaved caspase-3 indexes (p similar to<similar to 0.001), active metalloproteinase 2 (p similar to=similar to 0.004) and the number of glutathione S-transferase placental form (GST-P)-positive preneoplastic lesions (p similar to<similar to 0.05) in the liver from TAA-treated groups. In conclusion, conventional coffee and 0.1% caffeine intake presented better beneficial effects than decaffeinated coffee against liver injury induced by TAA in male Wistar rats.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experimental study on drag-reduction phenomenon in dispersed oil-water flow has been performed in a 26-mm-i.d. Twelve meter long horizontal glass pipe. The flow was characterized using a novel wire-mesh sensor based on capacitance measurements and high-speed video recording. New two-phase pressure gradient, volume fraction, and phase distribution data have been used in the analysis. Drag reduction and slip ratio were detected at oil volume fractions between 10 and 45% and high mixture Reynolds numbers, and with water as the dominant phase. Phase-fraction distribution diagrams and cross-sectional imaging of the flow suggested the presence of a higher amount of water near to the pipe wall. Based on that, a phenomenology for explaining drag reduction in dispersed flow in a flow situation where slip ratio is significant is proposed. A simple phenomenological model is developed and the agreement between model predictions and data, including data from the literature, is encouraging. (c) 2011 American Institute of Chemical Engineers AIChE J, 2012

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d(15) thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k(15) and piezoelectric stress constant e(15) when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d(15) MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Stereology is an established method to extrapolate three-dimensional quantities from two-dimensional images. It was applied to placentation in the mouse, but not yet for other rodents. Herein, we provide the first study on quantitative placental development in a sigmodontine rodent species with relatively similar gestational time. Placental structure was also compared to the mouse, in order to evaluate similarities and differences in developmental patterns at the end of gestation. Methods: Fetal and placental tissues of Necromys lasiurus were collected and weighed at 3 different stages of gestation (early, mid and late gestation) for placental stereology. The total and relative volumes of placenta and of its main layers were investigated. Volume fractions of labyrinth components were quantified by the One Stop method in 31 placentae collected from different individuals, using the Mercator® software. Data generated at the end of gestation from N. lasiurus placentae were compared to those of Mus musculus domesticus obtained at the same stage. Results: A significant increase in the total absolute volumes of the placenta and its main layers occurred from early to mid-gestation, followed by a reduction near term, with the labyrinth layer becoming the most prominent area. Moreover, at the end of gestation, the total volume of the mouse placenta was significantly increased compared to that of N. lasiurus although the proportions of the labyrinth layer and junctional zones were similar. Analysis of the volume fractions of the components in the labyrinth indicated a significant increase in fetal vessels and sinusoidal giant cells, a decrease in labyrinthine trophoblast whereas the proportion of maternal blood space remained stable in the course of gestation. On the other hand, in the mouse, volume fractions of fetal vessels and sinusoidal giant cells decreased whereas the volume fraction of labyrinthine trophoblast increased compared to N. lasiurus placenta. Conclusions: Placental development differed between N. lasiurus and M. musculus domesticus. In particular, the low placental efficiency in N. lasiurus seemed to induce morphological optimization of fetomaternal exchanges. In conclusion, despite similar structural aspects of placentation in these species, the quantitative dynamics showed important differences.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d15 thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k15 and piezoelectric stress constant e15 when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d15 MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.