13 resultados para Soft tecnologies

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this research was to study the influence of soft laser treatment on the process of bone repair after expansion of the midpalatal suture. Methods: The sample for this case-control experimental study was 11 dogs. They were randomly divided into 2 groups, both of which underwent rapid maxillary expansion with a hyrax appliance. The animals in group 1 were also treated with laser therapy. They were killed, and histologic specimens of the palatal suture were prepared. The Student t test was applied for independent data, and the Mann-Whitney test was used for nonparametric data. Results: A significant difference was observed in the quality of the palatal sutures between the animals in groups 1 and 2. The connective tissues of the sutures in the group 1 animals were similar to the original configurations, with more advanced osteogenesis and fibrogenesis, compared with those of group 2. Conclusions: Soft laser appears to influence the behavior of the repair process, contributing to suture reorganization and palatal bone osteogenesis during and after expansion. (Am J Orthod Dentofacial Orthop 2012; 142: 615-24)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates pure ionic liquids (ILs) derived from an imidazolium ring with different carbonic chains and halides or bis(trifluoromethanesulfonilimide) (TFSI-) as anions, using X-ray absorption near edge spectroscopy (XANES) at different energies (N, S, O, F, and Cl edges) to probe the interionic interactions. XANES data show that the interaction with the anion is weaker when the cation is an imidazolium than when the salt is formed by smaller cations, as lithium, independently of the length of the carbonic chain attached to the imidazolium cation. The results also show that, for all studied as, it is not observed any influence of the anion on the XANES spectra of the cation, nor the opposite. 1-Methylimidazolium with Cl-, a small and strongly coordinating anion, presents in the N K XANES spectrum a splitting of the band corresponding to nitrogen in the imidazolic ring, indicating two different chemical environments. For this cation with TFSI-, on the contrary, this splitting was not observed, showing that the anion has a weaker interaction with the imidazolic ring, even without a lateral carbonic chain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient's response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). Objectives: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. Materials and methods: Thirty-two complete denture wearers had their lower dentures relined with a silicone-based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP-EDENT, and the median scores were compared by Wilcoxon test (p <= 0.05). Results: After 3 months of relining, participants reported significant improvement of their OHRQoL (p <= 0.01). Conclusion: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated colour stability, hardness and roughness of soft denture liners after immersion in various cleansers. Materials and methods: Thirty specimens (14 mm x 4 mm) of Elite Soft Relining (ES) and Mucopren Soft (MS) were randomly immersed in distilled water at 37 degrees C, sodium hypochlorite 1%, and an experimental Ricinus communis solution (RC) for 7, 15 and 183 continuous days. Results: ANOVA (p < 0.05) and Tukey's test indicated that after T7 (mu =8.79 +/- 7.36); T15 (mu = 4.23 +/- 2.62) and T183 (mu = 8.78 +/- 3.16), MS presented a higher increase in hardness than ES. After T7, MS underwent an increase in roughness (mu = 0.09 +/- 0.80); ES underwent a decrease (mu = -0.08 +/- 0.16). RC caused the smallest variation in roughness. After T15, both materials presented an increase in roughness. After T183, ES (mu = -0.30 +/- 0.48) presented a higher roughness variation than MS (mu = -0.07 +/- 0.32). Hypochlorite caused an increase in roughness (mu = 0.02 +/- 0.19). Conclusion: After all periods ES presented higher colour alteration than MS; highest colour alteration was caused by hypochlorite. Both materials were more stable after immersion in RC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This in vitro study evaluated the effect of calcium glycerophosphate (CaGP) supplemented to soft drinks on bovine enamel erosion. Material and methods: Four pH-cycles were performed, alternating demineralization by the beverage and remineralization in artificial saliva. Results: Mean wear (+/- SD, mu m) was 7.91 +/- 1.13, 7.39 +/- 1.01, 7.50 +/- 0.91 and 5.21 +/- 1.08 for Coca-Cola (TM) without CaGP or containing CaGP at 0.1, 1.0 or 2.0 mM, respectively, while no wear was detected for CaGP at 5.0 and 10.0 mM. Corresponding figures for Sprite Zero (TM) without CaGP or containing CaGP at 0.1, 1.0, 2.0, 5.0 or 10.0 mM were 8.04 +/- 1.30, 7.84 +/- 0.71, 7.47 +/- 0.80, 4.96 +/- 0.81, 3.99 +/- 0.10 and 1.87 +/- 0.12, respectively. Conclusion: Supplementation of both beverages with CaGP seems to be an alternative to reduce their erosive potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among spiders, scorpions, and whip spiders, a common type of maternal care consists of females carrying newly hatched offspring on their body for a few days until they are able to live independently. While this maternal care has been suggested to occur in different argasid tick species, it has been recorded only once, for Antricola marginatus in Cuba; however, this earlier record only superficially mentioned the occurrence of this behavior, with no further details. Here we report the occurrence of maternal care in the argasid tick A. marginatus under natural conditions in a cave at Yucatan. Mexico, where 8 A. marginatus females, while walking on bat guano, had their body entirely covered by a mean number of 305 +/- 112 conspecific unfed larvae (range: 105-466). Larvae covered the entire idiosoma of the female tick, where they were motionless or displayed just slight movement. This result substantially expands the number of unique characters that have been found only in Antricola spp, ticks, when compared to the other tick genera. Our findings also indicate that maternal care evolved independently in different taxa of Arachnida, since it has been reported for species of Araneae, Scorpiones, and Amblypygi, and here for an Acari species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the photopolymerization kinetics and degree of conversion of different commercial dental composites when photoactivated by a LED curing unit using two different modes (standard and soft-start mode). The investigation was performed on with RelyX ARC (dual-cured), Filtek Z-350 (Nanocomposite), Filtek Z-250 (Hybrid), and Filtek Z-350flow (Flowable) resin composites. The analysis used was attenuated total reflection with a Fourier transform infrared (ATR-FTIR). The RelyX ARC resin demonstrated the highest degree of conversion with both LED photoactivation modes. For this resin a 28% decrease in maximum rate was observed and the time to reach its highest rate was almost 2.3 times higher than when the soft-start photoactivation light curing was used. Z-350flow resin recorder a higher maximum rate using the soft-start mode rather than the standard mode. In contrast, the Z-250 showed a higher value using the standard mode. Although Z-250 and Z-350 showed a higher total degree of conversion effectiveness using the soft-start mode, RelyX and Z-350flow achieved a higher value using the standard mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Facial reconstruction is a method that seeks to recreate a person's facial appearance from his/her skull. This technique can be the last resource used in a forensic investigation, when identification techniques such as DNA analysis, dental records, fingerprints and radiographic comparison cannot be used to identify a body or skeletal remains. To perform facial reconstruction, the data of facial soft tissue thickness are necessary. Scientific literature has described differences in the thickness of facial soft tissue between ethnic groups. There are different databases of soft tissue thickness published in the scientific literature. There are no literature records of facial reconstruction works carried out with data of soft tissues obtained from samples of Brazilian subjects. There are also no reports of digital forensic facial reconstruction performed in Brazil. There are two databases of soft tissue thickness published for the Brazilian population: one obtained from measurements performed in fresh cadavers (fresh cadavers' pattern), and another from measurements using magnetic resonance imaging (Magnetic Resonance pattern). This study aims to perform three different characterized digital forensic facial reconstructions (with hair, eyelashes and eyebrows) of a Brazilian subject (based on an international pattern and two Brazilian patterns for soft facial tissue thickness), and evaluate the digital forensic facial reconstructions comparing them to photos of the individual and other nine subjects. The DICOM data of the Computed Tomography (CT) donated by a volunteer were converted into stereolitography (STL) files and used for the creation of the digital facial reconstructions. Once the three reconstructions were performed, they were compared to photographs of the subject who had the face reconstructed and nine other subjects. Thirty examiners participated in this recognition process. The target subject was recognized by 26.67% of the examiners in the reconstruction performed with the Brazilian Magnetic Resonance Pattern, 23.33% in the reconstruction performed with the Brazilian Fresh Cadavers Pattern and 20.00% in the reconstruction performed with the International Pattern, in which the target-subject was the most recognized subject in the first two patterns. The rate of correct recognitions of the target subject indicate that the digital forensic facial reconstruction, conducted with parameters used in this study, may be a useful tool. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) is a therapeutic technique mainly applied to the treatment of malignant and pre-malignant lesions, which induces cell death by the combined effect of a photosensitizer, irradiation in a proper wavelength, and molecular oxygen. One of the main limitations of PDT using 5-aminolevulinic acid (ALA) is the superficial volume of treatment, mainly due to the limited penetration of topical photosensitization. In this context, the present study investigates if a laser micromachining producing microchannels on the tissue surface could improve ALA penetration and result in an increase in the treatment depth. The laser micromachining under femtosecond regime was performed on the tissue surface of rat livers. Conventional PDT was applied and the induced depth of necrosis with or without laser micromachining was compared. The results showed an increase of more than 20% in the depth of necrosis when the femtosecond laser micromachining was performed before the treatment with the PDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Genetic sonography following first-trimester combined screening appears to increase substantially detection rates for Down syndrome but it relies on the unproved assumption of independence between these tests. In this study we aimed to investigate the relationship between first-trimester nuchal translucency (NT) and a series of second-trimester soft markers and structural defects in unaffected pregnancies. Methods NT measurement in the first trimester was followed by second-trimester scan (18 to 23 + 6 weeks) including examination for three categorical markers (intracardiac echogenic foci, hyperechogenic bowel and structural defects) and measurement of nasal bone length, nuchal-fold thickness, femur length, humerus length, renal pelvis diameter and prenasal thickness. All continuous variables were expressed in multiples of the median (MoM) for gestation and correlation coefficients between log-transformed NT and second-trimester variables were calculated. In addition, frequencies of soft markers and structural defects in cases with increased NT were compared to those with normal NT, using MoM cut-offs. Results In a dataset of 1970 cases, NT was significantly correlated (P < 0.05) with all second-trimester continuous variables, the correlation being strongest for nuchal-fold thickness (r = 0.10). There was a higher frequency of cases with second-trimester nuchal-fold thickness above the 97.5th centile (10.7 vs. 2.2%) and hyperechogenic bowel (2.4 vs. 0.1%) in cases with increased NT. Conclusions Straightforward reassessment of risk using likelihood ratios derived from the second-trimester genetic sonogram might lead to inaccurate estimates. Multivariate models using continuous second-trimester variables might be preferable in sequential screening strategies. Copyright. 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topoisomerase 2 alpha (), HER-2/ and are genes that lie on chromosome 17 and correlate with the prognosis and prediction of target-driven therapy against tumors. In a previous study, we showed that TOP2A transcripts levels were significantly higher in soft tissue sarcomas (STS) than in benign tumors and desmoid-type fibromatoses (FM). Because these genes have been insufficiently examined in STS, we aimed to identify alterations in TOP2A and HER-2 expression by fluorescent in situ hybridization and immunohistochemistry, as well as that of survivin, and correlate them with clinicopathologic findings to assess their prognostic value. Eighteen FM and 244 STS were included. Fluorescent in situ hybridization and immunohistochemistry were performed on a tissue microarray. TOP2A and survivin were more highly expressed in sarcomas than in FM. TOP2A was an independent predictor of an unfavorable prognosis; it was combined with formerly established prognostic factors (primarily histologic grade and tumor size at diagnosis) to create a prognostic index that evaluated overall survival. Gene amplification/polysomy (13%) did not correlate with protein overexpression. Survivin and HER-2 expression were not associated with patient outcomes. These findings might become valuable in the management of patients with STS and possibly in the prospective evaluation of responses to new target-driven therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the short-and long-term treatment effects of rapid maxillary expansion (RME) on the soft tissue facial profile of subjects treated with a modified acrylic-hyrax device. The sample comprised 10 males and 10 females in the mixed dentition. Their average age was 9.3 years +/- 10 months pre-treatment (T1), with a narrow maxilla and posterior crossbite, treated with a modified fixed maxillary expander with an occlusal splint. Lateral cephalometric radiographs obtained at T1, immediately post-expansion (T2), and after retention (T3) were used to determine possible changes in the soft tissue facial profile. The means and standard deviations for linear and angular cephalometric measurements were analysed statistically using analysis of variance and Tukey's test (alpha = 0.05). The measurements at T2 differed significantly from those at T1 and T3. However, RME did not produce any statistically significant alteration (P > 0.05) in the soft tissue profile for any of the cephalometric landmarks evaluated when compared at T1 and T3. The use of a fixed expander associated with an occlusal splint did not cause significant alterations in the soft tissue facial profile at T3. This modified device is effective for preventing the adverse vertical effects of RME such as an increase anterior face height in patients with a crossbite.