8 resultados para Silicone Microimplants

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and scalable procedure was used to obtain thin, stable, homogeneous, and easy-to-handle films composed of silicone derived from dimethicones containing dispersed hydrotalcite-type materials previously organo-modified with amino acids. The absence of the typical X-ray pattern of the bioinorganic LDH filler suggested an exfoliation process that was further indirectly evidenced by a drastic change in the rheological behavior, which turned from a quasi-Newtonian behavior for the silicone free of LDH filler to an extensive developed gel-like structure for the nanocomposite derivatives. Visualized by the shear-thinning exponent of the complex viscosity in the low-frequency range, the percolation threshold was evident for filler loading as low as <5 w/W%, suggesting the presence of a largely developed interface between the filler and the polymer. The increase of more than one order of magnitude in viscosity was explained by the rather strong attrition phenomenon between the tethered amino acid anions and the silicone chains. UVB radiation absorption profiles make such bioinorganic polymer nanocomposites potentially applicable in skin protection. Thermo-gravimetric analysis revealed significant improvement in the thermal stability, especially in the final step of the polymer combustion, thus underlining the role of the hybrid material as a thermal retardant agent. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients with severe ptosis caused by poor or absent function of the levator muscle but with good frontalis muscle excursion usually benefit from a frontalis sling procedure. This is currently carried out using organic or inorganic material to connect the upper eyelid to the frontalis muscle. Methods: The aim of this study was to evaluate retrospectively 112 patients who underwent frontalis sling procedures between 1989 and 2011 using a preformed silicone implant suspensor to correct severe ptosis. Results: The results obtained using this technique were good or fair in 95.54 percent of the cases and poor in 4.46 percent of the cases. The authors discuss the results of the study and the cases in which the procedure should be indicated and highlight the advantages of the method. Conclusion: The availability of this low-cost sterile device, together with the fact that it is ready to use, requires less invasive surgery, saves time, and is sufficiently versatile to allow adjustments to be made at any time, makes the silicone eyelid sling an attractive choice for correcting ptosis. (Plast. Reconstr. Surg. 129: 453e, 2012.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient's response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). Objectives: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. Materials and methods: Thirty-two complete denture wearers had their lower dentures relined with a silicone-based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP-EDENT, and the median scores were compared by Wilcoxon test (p <= 0.05). Results: After 3 months of relining, participants reported significant improvement of their OHRQoL (p <= 0.01). Conclusion: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multiwall carbon nanotube/silicone rubber (MWCNT/SR) composite electrode has been used for the determination of hydrochlorothiazide (HCTZ) in pharmaceutical formulations by differential pulse voltammetry (DPV). The electro-oxidation process was evaluated by cyclic voltammetry, from which it was observed that HCTZ presents an irreversible oxidation peak at 0.82 V vs. saturated calomel electrode (SCE) in the potential range from 0.5 to 1.1 V, in Britton-Robinson buffer pH 7.0 at MWCNT/SR. HCTZ was determined by DPV using a MWCNT/SR 70% (MWCNT, m/m) composite electrode after the optimization of the experimental parameters. The linear range was from 5.0 to 70.0 mu mol L-1, with a limit of detection (LOD) of 2.6 mu mol L-1. The HCTZ was determined in pharmaceutical formulations using the proposed composite electrode and the results agreed with those from the official high performance liquid chromatography (HPLC) method within 95% confidence level, according to the t-Student test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To standardize the design of individually fitted implants based on computed tomographic (CT) images for use in medialization laryngoplasty without intraoperative voice monitoring. Study Design. Prospective tomographic and anatomical experimental study of 10 human cadaveric larynges. Methods. CT scans of 10 excised human larynges were analyzed to define the shape and size of ideal implants for medialization laryngoplasty. Silicone implants were designed according to CT parameters and used in simulated laryngoplasties in the laryngeal specimens. The efficacy of each implant in providing adequate medialization of the vocal fold was evaluated. Results. Diverse shapes and sizes of implants were obtained, reflecting variations in laryngeal anatomy. The implants enabled regular medialization of the entire extent of the free border of the vocal fold, including its posterior aspect. Medialization was considered adequate in all cases. Conclusions. This method proved to be a simple and efficient way to design individualized implants for medialization laryngoplasty, regardless of the size and shape of the larynx.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the role of transitory latex and sylastic (R) implants in tympanoplasty on the closure of tympanic perforations. METHODS: A randomized double-blind prospective study was conducted on 107 patients with chronic otitis media submitted to underlay tympanoplasty and divided at random into three groups: control with no transitory implant, latex membrane group, and sylastic (R) membrane group. RESULTS: Greater graft vascularization occurred in the latex membrane group (p<0.05). Good biocompatibility was obtained with the use of the latex and silicone implants, with no effect on the occurrence of infection, otorrhea or otorragy. CONCLUSION: The use of a transitory latex implant induced greater graft vascularization, with a biocompatible interaction with the tissue of the human tympanic membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the in vitro changes on the enamel surface after a micro-abrasion treatment promoted by different products. Material and Methods: Fifty (50) fragments of bovine enamel (15 mm × 5 mm) were randomly assigned to five groups (n=10) according to the product utilized: G1 (control)= silicone polisher (TDV), G2= 37% phosphoric acid (3M/ESPE) + pumice stone (SS White), G3= Micropol (DMC Equipment), G4= Opalustre (Ultradent) and G5= Whiteness RM (FGM Dental Products). Roughness and wear were the responsible variables used to analyze these surfaces in four stages: baseline, 60 s and 120 s after the micro-abrasion and after polishing, using a Hommel Tester T1000 device. After the tests, a normal distribution of data was verified, with repeated ANOVA analyses (p?0.05) which were used to compare each product in different stages. One-way ANOVA and Tukey tests were applied for individual comparisons between the products in each stage (p?0.05). Results: Means and standard deviations of roughness and wear (µm) after all the promoted stages were: G1=7.26(1.81)/13.16(2.67), G2=2.02(0.62)/37.44(3.33), G3=1.81(0.91)/34.93(6.92), G4=1.92(0.29)/38.42(0.65) and G5=1.98(0.53)/33.45(2.66). At 60 seconds, all products tended to produce less surface roughness with a variable gradual decrease over time. After polishing, there were no statistically significant differences between the groups, except for G1. Independent of the product utilized, the enamel wear occurred after the micro-abrasion. Conclusions: In this in vitro study, enamel micro-abrasion presented itself as a conservative approach, regardless of the type of the paste compound utilized. These products promoted minor roughness alterations and minimal wear. The use of phosphoric acid and pumice stone showed similar results to commercial products for the micro-abrasion with regard to the surface roughness and wear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: A partir da década de 1990 foram iniciados os primeiros tratamentos cirúrgicos da obesidade em adolescentes, seguindo a sequência cirurgia bariátrica, perda ponderal e dismorfismo corporal, criando demanda por cirurgias plásticas para readequação do contorno corporal. O objetivo deste estudo foi identificar fatores associados a cirurgias plásticas de readequação de contorno corporal (morbidade e mortalidade), realizadas em pacientes submetidos a cirurgia bariátrica durante a adolescência. MÉTODO: Entre janeiro de 2008 e janeiro de 2011, 5 pacientes submetidos a gastroplastia redutora durante a adolescência, com consequente perda e estabilização de peso, foram submetidos a cirurgias plásticas do contorno corporal. A média de idade no início das cirurgias plásticas foi de 19,7 anos, sendo 3 (60%) pacientes do sexo feminino. Foram realizadas dermolipectomias abdominais em todos (100%) os pacientes, dermolipectomias crurais em 4 (80%), dermolipectomias braquiais em 2 (40%), mamoplastia com inclusão de implantes de silicone em 2 (40%) pacientes do sexo feminino, mastopexia na terceira paciente do sexo feminino (20%) e correção de ginecomastia em 1 (20%), toracoplastia em 2 (40%), torsoplastia em 2 (40%) e torsoplastia reversa em 1 (20%). Foram realizadas, em média, 3 intervenções cirúrgicas por paciente, sendo operados 20 sítios cirúrgicos. RESULTADOS: Ocorreram deiscências em 3 (15% dos sítios cirúrgicos) casos e foi necessário revisar a ressecção dermogordurosa por flacidez residual em 3 (15% dos sítios cirúrgicos) casos. CONCLUSÕES: Foram identificados alguns fatores associados às cirurgias plásticas de readequação de contorno corporal na amostra de 5 pacientes submetidos a cirurgia bariátrica durante a adolescência, comparáveis aos da literatura específica.